Abstract
Curtain walling is assuming more and more a leading role in tall building architectural design.
From a structural standpoint, there is no doubt that the wind action is the main loading condition, governing all the dimensioning of any curtain wall single component. On the other hand, the wind action is sensitive to any curtain wall local shape discontinuity, or composition peculiarity, which may modify the load intensity on a micro-scale, but still important for structural safety.
On such respect, the structural engineer may have to cope with some recurrent issues:
-
to define wind loads during an initial tender phase, when no wind tunnel test has been developed yet;
-
to define wind loads for the cladding of a building that will never have the aid of a wind tunnel test;
-
to define wind loads on components that have not been simulated in the wind tunnel test, because their size was too small when scaled to the wind tunnel test model.
Published standards are the main support to this activity, but this paper will show some frequent cases that are still missing, or just partially treated, in the international standards, like:
-
Façade projections, i.e. canopies, balconies, sun-shadings, etc.;
-
Buildings with curved surfaces but non-circular shape;
-
Cladding elements with more than one skin.
Examples from the everyday design work will be shown.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Notes
- 1.
A similar approach has been followed by Windtech Consultants® in some of their wind tunnel test reports.
References
Cook NJ (1990) The designer’s guide to wind loading of building structures. Part 2: static structures. Building Research Establishment Report, Butterworths
EN 1991-1-4 (2005) Eurocode 1: actions on structures - Part 1–4: general actions - wind actions
Jancauskas E, Holmes J (1985) Wind loads on attached canopies. In: US national conference on wind engineering, proceedings, Texas Tech University, Lubbock
Roh HW, Kim HR (2011) Wind pressure distribution on canopies attached to tall buildings. J Mech Sci Technol 25(7):1767–1774
SIA 261 (2014) Actions on structures
DIN EN 1991-1-4/NA (2010) National annex – nationally determined parameters – Eurocode 1: actions on structures – Part 1–4: general actions - wind actions
AS/NZS 1170.2:2002. Australian/New Zealand standards, structural design actions- Part-2, wind actions, Jointly published by Standards Australia International Ltd., Sydney and Standards New Zealand, Wellington
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this paper
Cite this paper
Manara, G. (2019). Some Topics About Wind Engineering that Curtain Walling Design Might Be Longing for in Standards. In: Ricciardelli, F., Avossa, A. (eds) Proceedings of the XV Conference of the Italian Association for Wind Engineering. IN VENTO 2018. Lecture Notes in Civil Engineering, vol 27. Springer, Cham. https://doi.org/10.1007/978-3-030-12815-9_36
Download citation
DOI: https://doi.org/10.1007/978-3-030-12815-9_36
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-12814-2
Online ISBN: 978-3-030-12815-9
eBook Packages: EngineeringEngineering (R0)