Abstract
Operating overvoltage in power grid is one of the important reasons of high-voltage equipment damage. It is accompanied by the operation of the power grid equipment, and power grid overvoltage calculation must be applied to the new project commissioning, especially the UHV project in order to understand the overvoltage conditions, take protective measures to prevent damage to equipment. Based on power electronics and electromagnetic transient calculation program, in the paper author established an electromagnetic transient model of the ±800 kV converter station ac system. Simulation analysis is carried out for the possible operating overvoltage during the start-up and debugging of the ac system. It is helpful to provide technical basis for debugging scheme, at the same time provide data for the operation and maintenance of the converter station in the future.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Bo, L., Xianting, M., Yiling, G.: Theory analysis for distribution transformer to occur ferro-resonant overvoltage. Electr. Saucer Power 30(4), 288–290 (2008, in Chinese)
Wei, W., Shengchang, J., Tao, C., et al.: Theoretical analysis and experimental verification of fundamental frequency ferroresonance. Power Syst. Technol. 33(17), 226–230 (2009, in Chinese)
Fan, L., Caixin, S., Wenxia, S., et al.: The theoretical analysis of chaotic ferroresonance overvoltage in power systems. Trans. China Electrotech. Soc. 21(2), 103–107 (2006, in Chinese)
Yunge, L., Wei, S.: The study of fundamental ferroresonance on neutral-grounded systems by using analytical method, the solution to the power frequency excitation characteristic of nonlinear inductors. Proc. CSEE 23(10), 94–98 (2003, in Chinese)
Kieny, C.: Application of the bifurcation theory in studying and understanding the global behavior of a ferroresonant electric power circuit. IEEE Trans. Power Deliv. 6(2), 866–871 (1991)
Bohmann, L.J., McDaniel, J., Stanek, E.K.: Lightning arrester failure and ferroresonance on a distribution system. IEEE Trans. Power Deliv. 9(6):1189–1195 (1993)
Shott, H.S., Peterson, H A.: Criteria for neutral stability of wye-grounded primary broken-delta-secondary transformer circuit. Trans. AIEE 24(4), 997–1002 (1941)
Fan, L., Wenxia, S., Caixin, S., et al.; Resonance overvoltage based on constant pulse method. Power Syst. Technol. 30(3), 57–61 (2006, in Chinese)
Hua, L., Bin, W., Yanliang, Y., et al.: Influence of excitation characteristics of PT on ferroresonance and detection research. Electr. Measur. Instrum. 538, 10–12 (2010, in Chinese)
Yi, H., Yanxia, Z.: Detection of ferroresonance in neutral non-grounding system based on decomposition characteristic of wavelet packet. Power Syst. Technol. 30(23), 72–76 (2006, in Chinese)
Abebe, Y.M., Mallikarjuna Rao, P., Gopichand Nak, M.: Load flow analysis of a power system network in the presence of uncertainty using complex affine arithmetic. Int. J. Eng. Manuf. (IJEM) 7(5), 48–64 (2017). https://doi.org/10.5815/ijem.2017.05.05
Zhang, M., Xia, C.: A loose wavelet nonlinear regression neural network load forecasting model and error analysis based on SPSS. Int. J. Inf. Technol. Comput. Sci. (IJITCS) 9(4), 24–30 (2017). https://doi.org/10.5815/ijitcs.2017.04.04
Ibrahim, N.M.A., Attia, H.E. M., Talaat, H.E.A., Kasem Alaboudy, A.H.: Modified particle swarm optimization based proportional-derivative power system stabilizer. Int. J. Intell. Syst. Appl. (IJISA) 7(3), 62–76 (2015). https://doi.org/10.5815/ijisa.2015.03.08
Singhal, P., Agarwal, S.K., Kumar, N.: Advanced adaptive particle swarm optimization based SVC controller for power system stability. Int. J. Intell. Syst. Appl. (IJISA) 7(1), 101–110 (2015). https://doi.org/10.5815/ijisa.2015.01.10
Noubissi, J.-H., Kamgang, J.C., Ramat, E., Asongu, J., Cambier, C.: Meta-population modelling and simulation of the dynamic of malaria transmission with influence of climatic factors. Int. J. Inf. Technol. Comput. Sci. (IJITCS) 9(7), 1–16 (2017). https://doi.org/10.5815/ijitcs.2017.07.01
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Switzerland AG
About this paper
Cite this paper
Ren, Z., Fan, J., Chen, X., Gao, H., Lu, J., Zheng, B. (2020). Simulation and Analysis of Operating Overvoltage of AC System at ±800 kV Converter Station Based on EMTS/EMTPE. In: Hu, Z., Petoukhov, S., He, M. (eds) Advances in Artificial Systems for Medicine and Education II. AIMEE2018 2018. Advances in Intelligent Systems and Computing, vol 902. Springer, Cham. https://doi.org/10.1007/978-3-030-12082-5_66
Download citation
DOI: https://doi.org/10.1007/978-3-030-12082-5_66
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-12081-8
Online ISBN: 978-3-030-12082-5
eBook Packages: Intelligent Technologies and RoboticsIntelligent Technologies and Robotics (R0)