Abstract
Topography is useful for the fitting of contact lenses, particularly in irregular corneas and for rigid lenses. By identifying the curvature of the steepest and flattest areas of the cornea and generating a simulated fluorescein pattern, it can direct the selection of the initial back surface curvature to be tried, thereby reducing the number of trial lenses required. It can also inform the design of custom design lenses.
Corneal irregularity can cause visual loss which is correctable by rigid contact lenses, but not by glasses. Topography is valuable in identifying such cases. In severe cases, such information can be sent to contact lens manufacturers to inform custom lens designs.
Monitoring post-fitting can detect contact lens-induced corneal warpage, due to sustained pressure from the lens in areas of touch. Various patterns can occur, including changes of astigmatism, irregular astigmatism, oblate pattern (flattening centrally and steepening towards the periphery) and a steep-flat pattern with flattening under an eccentric lens with corresponding steepening elsewhere. If the steepening is inferior, this may mimic keratoconus. Warpage tends to reverse after several weeks without lens wear, but if lenses have been worn for many years, the corneal shape may never return to normal. Warpage should have reversed as fully as possible prior to taking measurements for biometry or refractive surgery.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
*References Particularly Worth Reading
ACLM Industry Statistics – contact lens market. Today; March 28th 1994; 23.
Dart JKG. Predisposing factors in microbial keratitis: the significance of contact lens wear. Br J Ophthalmol. 1988;72:926–30.
Dart JKG, Stapleton F, Minassian D. Contact lenses and other risk factors in microbial keratitis. Lancet. 1991;338:650–3.
Schein OD, Glynn RJ, Poggio EC, Seddon JM, Kenyon KR. The relative risk of ulcerative keratitis among users of daily-wear and extended-wear soft contact lenses: a case-control study. Microbial Keratitis Study Group. N Engl J Med. 1989;321(12):773–8.
Poggio EC, Glynn RJ, Schein OD, Seddon JM, Shannon MJ, Scardino VA, Kenyon KR. The incidence of ulcerative keratitis among users of daily-wear and extended-wear soft contact lenses. N Engl J Med. 1989;321:779–83.
Stern GA. Contact lens associated bacterial keratitis: past, present, and future. CLAO J. 1998;24(1):52–6.
Keay L, Stapleton F, Schein O. Epidemiology of contact lens-related inflammation and microbial keratitis: a 20-year perspective. Eye Contact Lens. 2007;33:346–53.
Stone J, Phillips AJ. Contact lenses. London: Butterworths; 1989.
Douthwaite WA. Contact lens optics. London: Butterworths; 1987.
*Stevenson RWW, Corbett MC, O’Brart DPS, Rosen ES. Corneal topography in contact lens fitting. Eur J Implant Ref Surg. 1995;7(5):305–317.
Fredrick S, Wilson G. The relation between eyelid tension, corneal toricity, and age. Invest Ophthalmol Vis Sci. 1983;24:1367–73.
Schnider CM, Kennedy L, Mintle L, Carr C, Hnatko T. Comparison of computerised corneal topography device nomogram and topographical fits to trial lens fitting. Invest Ophthalmol Vis Sci. 1995;36(Suppl):1458.
Szcotka LB, Capretta DM, Lass JH. Effect of computerised titration on videokeratoscope contact lens fitting. Invest Ophthalmol Vis Sci. 1995;36(Suppl):1458.
*Szczota LB, Capretta DM, Lass JH. Clinical evaluation of a computerised topography software method for fitting rigid gas permeable contact lenses. CLAO J. 1995;20:231–235.
Szczotka LB. Evaluation of a topographically based contact lens fitting software. Optom Vis Sci. 1997;74:14–9.
*Astin CLK, Gartry DS, Steele ADMcG. Contact lens fitting after photorefractive keratectomy. Br J Ophthalmol. 1996;80:597–603.
McCarey B, Zurawski C, O’Shea D. Practical aspects of a corneal topography system. CLAO J. 1992;18:248–54.
Wang X, McCulley JP, Bowman RW, et al. Time to resolution of contact lens-induced corneal warpage prior to refractive surgery. CLAO J. 2002;28(4):169–71.
Ruiz-Montenegro J, Mafra CH, Wilson SE, Jumper JM, Klyce SD, Mendelson EN. Corneal topographic alterations in normal contact lens wearers. Ophthalmology. 1993;100:128–34.
*Wilson SE, Lin DTC, Klyce SD, Reidy JJ, Insler MS. Topographic changes in contact lens-induced warpage. Ophthalmology. 1990;97:734–744.
*Wilson SE, Klyce SD. Screening for corneal topographic abnormalities before refractive surgery. Ophthalmology. 1994;101:147–152.
Corbett MC, O’Brart DPS, Marshall J. Biological and environmental risk factors for regression after photorefractive keratectomy. Ophthalmology. 1996;103:1381–91.
Phillips AJ. Orthokeratology – an alternative to excimer laser. J BCLA. 1995;18:65–71.
Hsiao CH, Lin HC, Chen YF, Ma DHK, Yeh LK, Tan HY, Huang SCM, Lin KK. Infectious keratitis related to overnight orthokeratology. Cornea. 2005;24:783–8.
Tseng CH, Fong CF, Chen WL, Hou YC, Wang IJ, Hu FR. Overnight orthokeratology-associated microbial keratitis. Cornea. 2005;24(7):778–82.
Yepes N, Lee SB, Hill V, Ashenhurst M, Saunders PP, Slomovic AR. Infectious keratitis after overnight orthokeratology in Canada. Cornea. 2005;24(7):857–60.
Nesburn AB, Bahri S, Salz J, Rabinowitz YS, Maguen E, Hofbauer J, Belin M, Macy JI. Keratoconus detected by videokeratography in candidates for photorefractive keratectomy. J Refract Surg. 1995;11:194–201.
Stevenson RWW. Analysis of post-PRK topography maps. Invest Ophthalmol Vis Sci. 1995;36(Suppl):1792.
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Corbett, M., Maycock, N., Rosen, E., O’Brart, D. (2019). Contact Lens Practice. In: Corneal Topography. Springer, Cham. https://doi.org/10.1007/978-3-030-10696-6_7
Download citation
DOI: https://doi.org/10.1007/978-3-030-10696-6_7
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-10694-2
Online ISBN: 978-3-030-10696-6
eBook Packages: MedicineMedicine (R0)