Abstract
In this chapter, the peculiar aspects of the normal neonatal EEG are discussed, alongside with the recording modalities and the characteristic and age-specific electroencephalographic physiological patterns of the newborn, from preterm birth to the end of the neonatal period. In the iconographic material the physiological markers of electrogenesis maturation have been highlighted; in the Appendix, the terms utilized to describe the neonatal EEG will be defined. The knowledge of normal EEG patterns is a prerequisite for the interpretation of the abnormal neonatal EEG.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Lamblin MD, Andre M, Auzoux M, et al. Indications of electroencephalogram in the newborn. Arch Pediatr. 2004;11(7):829–33.
Parmelee AH Jr, Schulte FJ, Akiyama Y, et al. Maturation of EEG activity during sleep in premature infants. Electroencephalogr Clin Neurophysiol. 1968;24:319–29.
Dreyfus-Brisac C, Monod N. The electroencephalogram of full term newborn and premature infants. In: Remond A, editor. Handbook of electroencephalography and clinical neurophysiology, vol. 6B. Amsterdam: Elsevier; 1975. p. 6–23.
Monod N, Tharp B. Activité electroencéphalographique normale du nouveau-né et du prématuré au cours des états de veille et de sommeil. Rev Electroenceph Neurophysiol Clin. 1977;7:302–15.
Watanabe K, Iwase K. Spindle-like fast rhythms in the EEGs of low birthweight infants. Dev Med Child Neurol. 1972;14:373–81.
Watanabe K, Iwase K, Hara K. Developmental of slow-wave sleep in low birth weight infants. Dev Med Child Neurol. 1974;16:23–32.
Tharp BR, Cukier F, Monod N. Valeur prognostique de l’EEG du prématuré. Neurophysiology. 1977;7:386–91.
Lombroso CT. Quantified electrographic scales on 10 pre-term healthy newborns followed up to 40–43 weeks of conceptional age by serial polygraphic recordings. Electroencephalogr Clin Neurophysiol. 1979;46:460–74.
Lombroso CT. Neonatal electroencephalography. In: Niedermeyer E, Lopes da Silva F, editors. Electroencephalography: basic principles, clinical applications and related field. Munich: Urban & Schwartzenberg; 1982. p. 725–62.
Tharp BR. Electrophysiological brain maturation in premature infants: an historical perspective. J Clin Neurophysiol. 1990;7(3):302–14.
Stockard-Pope JE, Wener SS, Bickford R. Atlas of neonatal electroencephalography. 2nd ed. New York: Raven; 1992.
Lombroso CT. Neonatal polygraphy in full-term and premature infants: a review of normal and abnormal findings. J Clin Neurophysiol. 1985;2:105–55.
Hrachovy RA, Mizrahi EM, Kellaway P. Electroencephalography of the newborn. In: Daly DD, Pedley TA, editors. Current practice of clinical electroencephalography. 2nd ed. New York: Raven; 1990. p. 201–42.
Mizrahi EM, Kellaway P. Neonatal electroencephalography. In: Diagnosis and management of neonatal seizures. Philadelphia, PA: Lippincott-Raven; 1998. p. 99–143.
Mizrhai EM, Hrachovy RA, Kellaway P. Atlas of neonatal electroencephalography. 3rd ed. Philadelphia, PA: Lippincott Williams & Wilkins; 2004.
Karayiannis NB, Xiong Y, Tao G, et al. Automated detection of videotaped neonatal seizures of epileptic origin. Epilepsia. 2006;47(6):966–80.
Stevenson NJ, Boylan GB. Advances in neurophysiology and neonatal seizures: automated seizures detection. In: Nagarajan L, editor. Neonatal seizures. Current management and future challenges. London: Mac Keith Press; 2016. p. 56–75.
Kuratani J, Pearl PL, Sullivan L, et al. American Clinical Neurophysiology Society Guideline 5: minimum technical standards for pediatric electroencephalography. J Clin Neurophysiol. 2016;33(4):320–3.
Shellhaas RA, Chang T, Tsuchida T, et al. The American Clinical Neurophysiology Society’s Guideline on continuous electroencephalography monitoring in neonates. J Clin Neurophysiol. 2011;28(6):611–7.
De Weerd AW, Despland PA, Plouin P. Neonatal EEG. The international federation of clinical neurophysiology. Electroencephalogr Clin Neurophysiol Suppl. 1999;52:149–57.
Chang T, Tsuchida TN. Conventional (continuous) EEG monitoring in the NICU. Curr Pediatr Rev. 2014;10(1):2–10.
Jasper HH. The ten-twenty electrodes system of the International Federation. In: International Federation of Societies for Electroencephalography and clinical neurophysiology: recommendations for the practice of clinical neurophysiology. Amsterdam: Elsevier; 1983. p. 3–10.
Nagarajan L, Gosh S. The role of the video EEG in neonates with seizures. In: Nagarajan L, editor. Neonatal seizures. Current management and future challenges. London: Mac Keith Press; 2016. p. 12–29.
Prechtl HFR, Beintema D. The neurological examination of the full term newborn infant. Clinics in Dev Med 12. London: Spastics Society and Heinemann; 1964.
Vecchierini MF, d’Allest AM, Verpillat P. EEG pattern in 10 extreme premature neonates with normal neurological outcome: qualitative and quantitative data. Brain and Development. 2003;25:330–7.
Biagioni E, Frisone MF, Laroche S, et al. Occipital sawtooth: a physiological EEG pattern in very premature infants. Clin Neurophysiol. 2000;111:2145–9.
Tharp B. Neonatal and pediatric electroencephalography. In: Aminoff M, editor. Electrodiagnosis in clinical neurology. New York: Churchill Livingston; 1986. p. 77–124.
Anders T, Emde R, Parmelee AH Jr. A manual of standardized terminology, techniques and criteria for scoring of states of sleep and wakefulness in newborn infants. Los Angeles: UCLA Brain Information Service, NIDS Neurological Information Network; 1971.
Kellaway P. Introduction to plasticity and sensitive periods. In: Kellaway P, Noebels JL, editors. Problems and concept in developmental neurophysiology. Baltimore: The Johns Hopkins University Press; 1989. p. 3–28.
Ferrari F, Biagioni E, Cioni G. Neonatal electroencephalography. In: Levene MI, Chervenak FA, Whittle M, editors. Fetal and neonatal neurology and neurosurgery. 3rd ed. London: Churchill Livingston; 2001. p. 155–80.
Mastrangelo M, Scelsa B, Fiocchi I, et al. EEG neonatale. In: Mecarelli O, editor. Manuale Teorico Pratico di Elettroencefalografia. 1st ed. Philadelphia, PA: Wolters Kluwer Health; 2009. p. 166–93.
André M, Lamblin MD, d’Allest AM, et al. Electroencephalography in premature and full-term infants. Developmental features and glossary. Neurophysiol Clin. 2010;40(2):59–124.
Boylan G, Burgoyne L, Moore C, et al. An international survey of EEG use in the neonatal intensive care unit. Acta Paediatr. 2010;99:1150–5.
Toet MC, Van Der Meij W, De Vries LS, et al. Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates. Pediatrics. 2002;109(5):772–9.
Hellström-Westas L. Comparison between tape-recorded and amplitude-integrated EEG monitoring in sick newborn infants. Acta Paediatr. 1992;81(10):812–9.
Lavery S, Shah DK, Hunt RW, et al. Single versus bihemispheric amplitude-integrated electroencephalography in relation to cerebral injury and outcome in the term encephalopathic infant. J Paediatr Child Health. 2008;44(5):285–90.
Mathur AM, Morris LD, Teteh F, et al. Utility of prolonged bedside amplitude-integrated encephalogram in encephalopathic infants. Am J Perinatol. 2008;25(10):611–5.
Shelhaas RA, Chang T, Tsuchida T, et al. The American clinical neurophysiology society’s guideline on continuous electroencephalography monitoring in neonates. J Clin Neurophysiol. 2011;28:611–7.
Abend NS, Wusthoff CJ. Neonatal seizures and status epilepticus. J Clin Neurophysiol. 2012;29:441–8.
Mastrangelo M, Fiocchi I, Fontana P, et al. Acute neonatal encephalopathy and seizures recurrence: a combined aEEG/EEG study. Seizure. 2013;22(9):703–7.
Rennie JM, Chorley G, Boylan GB, et al. Non-expert use of the cerebral function monitor for neonatal seizure detection. Arch Dis Child Fetal Neonatal Ed. 2004;89:F37–40.
Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection. Pediatrics. 2007;120:770–7.
Shah DK, Mackay MT, Lavery S, et al. Accuracy of bedside electroencephalographic monitoring in comparison with simultaneous continuous conventional electroencephalography for seizure detection in term infants. Pediatrics. 2008;121:1146–54.
Zimbric MR, Sharpe CM, Albright KC, et al. Three-channel electroencephalogram montage in neonatal seizure detection and quantification. Pediatr Neurol. 2011;44:31–4.
McCoy B, Hahn CD. Continuous EEG monitoring in the neonatal intensive care unit. J Clin Neurophysiol. 2013;30:106–14.
Shah DK, Boylan GB, Rennie JM. Monitoring of seizures in the newborn. Arch Dis Child Fetal Neonatal Ed. 2012;97:F65–9.
Acknowledgments
-
To the EEG technicians of the Pediatric Neurology Unit: Francesca Tabarelli, Deborah Meroni, and Gaetano Turi for their competence and sensitivity, constantly expressed in the management of newborns and in the acquisition of EEG recordings.
-
To the colleagues of the Pediatric Neurology Unit and Neonatology and Neonatal Intensive Therapy Unit of the Buzzi Children’s Hospital, for the daily fruitful collaboration.
-
To Dr. Alfredo Radaelli and Davide Radaelli, for their essential advices in preparing the figures and the manuscript.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Appendix
Appendix
Glossary
Activité moyenne: EEG pattern of the full-term newborn corresponding to wakefulness or to active sleep after quiet sleep state. Continuous electric activity with prevalent frequencies between 4 and 7 Hz (1–10 Hz), with an amplitude between 25 and 50 μV, with intermixed low-voltage delta activity.
-
Activity at 0–3 Hz: slow waves at 0.3–3 Hz, of amplitude up to 300 μV, in the preterm newborn of less than 26 weeks GA.
-
Activity at 3–7 Hz activity: occipital and isolated or in short runs of 1–2 s, of amplitude between 50 and 200 μV, in the preterm newborn of less than 27 weeks GA.
-
Activity at 8–13 Hz: in short runs of 1–2 s, of amplitude between 25 and 30 μV, prevalent on Rolandic and occipital regions, in the preterm newborn of less than 28 weeks GA.
Anterior slow dysrhythmia (ASD): physiological pattern of the term newborn. In the neonatal period, the word dysrhythmia is still accepted—the ASD is characterized by a short sequence of 1–2 s of anterior slow waves at 2–3 Hz and of amplitude between 50 and 150 μV, synchronous (and asynchronous), sometimes associated with the frontal sharp transients.
Background activity: it includes the predominant frequencies and amplitudes with their variability, in relation to the spatial and temporal parameters, during the EEG recording. The background activity can be continuous or discontinuous depending on the presence, or not, in a given recording period, significant changes in the frequency, and/or amplitude of the electrical activity. However, the term “discontinuous” is used to define the recordings in which there are sections of significant voltage attenuation up to the absence of electrical activity. In relation to the clinical meanings of the “discontinuous tracing,” the reader might refer to the iconography of this chapter and of the following chapter concerning the pathologic neonatal EEG recordings.
Conceptional age (CA): GA plus the weeks since birth; gestational age, measured from the time of the last menstrual period + chronological age.
Concordance and discordance: the presence or absence of regularly structured electrical and behavioral parameters, in relation to the specific state in the different GA.
Delta brush: physiological transient of the preterm and healthy newborn, with variable localization depending on the GA. It is a complex transient in which fast activity at 8–22 Hz, generally of low voltage (10–70 μV), immediately precedes; it is superimposed or immediately follows a high-amplitude slow wave at 0.3–1.5 Hz, between 75 and 250 μV of amplitude. The characteristics of both fast activity and slow wave vary according to the degree of prematurity.
Dysmaturity: EEG characteristic due to the presence of an electric pattern corresponding to a lower GA than expected for that specific GA.
Encoches frontales (frontal sharp transients): typical physiological features since 35 weeks’ GA, characterized by a biphasic wave (negative-positive) of amplitude variable between 50 and 200 μV, anteriorly localized, bilaterally synchronous and asynchronous; observable until the end of the neonatal period in quiet sleep state.
Gestational age (GA): the number of weeks since the beginning of the last menstrual.
High-voltage slow (HVS): slow pattern of high voltage—electric pattern of the full-term newborn during the quiet sleep state: frequencies between 0.5 and 4 Hz, of amplitude between 50 and 150 μV, irregularly rhythmic.
Liability: poorly definable or unstable behavioral state.
Low-voltage irregular (LVI): low-voltage irregular pattern—electric pattern of the full-term newborn, corresponding to the active sleep that appears after a quiet sleep phase: frequencies between 1 and 8 Hz with amplitude lower than 40–60 μV.
Mixed activity: electric pattern of the full-term infant corresponding to the active sleep that generally appears at the beginning of a sleep cycle. It is constituted by the moyenne activité pattern over which theta-delta activity at 2–4 Hz is superimposed, with an amplitude of less than 100 μV.
Neonatal period: the first 4 weeks of life for the full-term newborn (40 weeks’ GA) and in any case up to the 44 weeks of GA for the preterm newborn:
-
Preterm newborn: born before 37 weeks of GA.
-
Term newborn: born between 38 and 42 weeks of GA.
-
Post-term newborn: born over 42 weeks of GA.
Paroxysmal: mode of appearance of an electrical event that begins and ends abruptly, clearly distinguishing itself from the background activity, generally of higher but sometimes of lower amplitude.
Positive and negative (temporal/Rolandic sharp waves): phase reversal in a bipolar derivation with variable localization, generally isolated and with voltage lower than 100 μV. Otherwise, they have a connotation of focal pathological transients and/or white matter involvement (positive Rolandic sharp waves).
Reactivity: modification of the background activity after external stimulation.
Sharp transients: spike or sharp wave transients that maintain the same morphological definition usually used in electroencephalography at any age but in the neonatal period are frequently typical physiological features of specific GA.
State: well-defined behavioral modality characterized by physiological events that occur in specific epochs of postnatal life both in the full-term and in the preterm newborn, with a predictable and cyclical trend.
Temporal spike and sharp waves: physiological elements, of variable amplitude, peculiar to an age between 29 and 32 weeks’ and at 37 weeks’ GA (multifocal interburst sharp waves).
Temporal theta burst or temporal sawtooth: peculiar physiological elements of the preterm newborn <33 weeks’ GA—short sequences of 3–5 s of diffuse rhythmic activity at 4–7 Hz, of amplitude between 50 and 250 μV, synchronous on the same hemisphere or more evident in the temporal region, bilaterally synchronous and asynchronous.
Tracé alternant (TA, alternating tracing): electric pattern of the full-term newborn observable in the quiet sleep—epochs of 3–8 s with delta activity at 0.5–3 Hz of amplitude between 50 and 200 μV, with superimposed fast activity of lower voltage, interspersed with sections of 3–8 s with theta activity at 4–6 Hz of amplitude between 25 and 40 μV.
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Mastrangelo, M., Scelsa, B., Pisani, F. (2019). Normal Neonatal EEG. In: Mecarelli, O. (eds) Clinical Electroencephalography. Springer, Cham. https://doi.org/10.1007/978-3-030-04573-9_11
Download citation
DOI: https://doi.org/10.1007/978-3-030-04573-9_11
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-04572-2
Online ISBN: 978-3-030-04573-9
eBook Packages: MedicineMedicine (R0)