Abstract
During the preoperative period, review of the posteroanterior chest radiograph is necessary to measure the tracheal width and also appreciate the pattern of the tracheobronchial anatomy to determine what device and size to use. The left-sided DLT is the most common device used for lung isolation because of its greater margin of safety. The use of bronchial blockers is indicated in patients who present with difficult airways and require lung isolation. Patients with a tracheostomy in place requiring lung isolation are best managed with the use of an independent bronchial blocker and flexible fiberoptic bronchoscopy. Flexible fiberoptic bronchoscopy is the recommended method to achieve optimal position of lung isolation devices, first in supine position, later in lateral decubitus, or whenever a malposition occurs.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Campos JH. Current techniques for perioperative lung isolation in adults. Anesthesiology. 2002;97:1295–301.
Campos JH. Progress in lung separation. Thorac Surg Clin. 2005;15:71–83.
Lewis JW Jr, Serwin JP, Gabriel FS, Bastanfar M, Jacobsen G. The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical procedures. J Cardiothorac Vasc Anesth. 1992;6:705–10.
Schuepbach R, Grande B, Camen G, et al. Intubation with VivaSight or conventional left-sided double-lumen tubes: a randomized trial. Can J Anaesth. 2015;62:762–9.
Campos JH. An update on bronchial blockers during lung separation techniques in adults. Anesth Analg. 2003;97:1266–74.
Campos JH, Kernstine KH. A comparison of a left-sided Broncho-Cath with the torque control blocker univent and the wire-guided blocker. Anesth Analg. 2003;96:283–9.
Arndt GA, Kranner PW, Rusy DA, Love R. Single-lung ventilation in a critically ill patient using a fiberoptically directed wire-guided endobronchial blocker. Anesthesiology. 1999;90:1484–6.
Cohen E. The Cohen flexitip endobronchial blocker: an alternative to a double lumen tube. Anesth Analg. 2005;101:1877–9.
Narayanaswamy M, McRae K, Slinger P, et al. Choosing a lung isolation device for thoracic surgery: a randomized trial of three bronchial blockers versus double-lumen tubes. Anesth Analg. 2009;108:1097–101.
Ruetzler K, Grubhofer G, Schmid W, et al. Randomized clinical trial comparing double-lumen tube and EZ-blocker for single-lung ventilation. Br J Anaesth. 2011;106:896–0.
Bjork VO, Carlens E. The prevention of spread during pulmonary resection by the use of a double-lumen catheter. J Thorac Surg. 1950;20:151–7.
Campos JH, Massa FC, Kernstine KH. The incidence of right upper-lobe collapse when comparing a right-sided double-lumen tube versus a modified left double-lumen tube for left-sided thoracic surgery. Anesth Analg. 2000;90:535–40.
Seymour AH, Prakash N. A cadaver study to measure the adult glottis and subglottis: defining a problem associated with the use of double-lumen tubes. J Cardiothorac Vasc Anesth. 2002;16:196–8.
Sivalingam P, Tio R. Tension pneumothorax, pneumomediastinum, pneumoperitoneum, and subcutaneous emphysema in a 15-year-old Chinese girl after a double-lumen tube intubation and one-lung ventilation. J Cardiothorac Vasc Anesth. 1999;13:312–5.
Bardoczky G, d’Hollander A, Yernault JC, et al. On-line expiratory flow-volume curves during thoracic surgery: occurrence of auto-PEEP. Br J Anaesth. 1994;72:25–8.
Sakuragi T, Kumano K, Yasumoto M, Dan K. Rupture of the left main-stem bronchus by the tracheal portion of a double-lumen endobronchial tube. Acta Anaesthesiol Scand. 1997;41:1218–20.
Hannallah M, Gomes M. Bronchial rupture associated with the use of a double-lumen tube in a small adult. Anesthesiology. 1989;71:457–8.
Brodsky JB, Macario A, Mark JB. Tracheal diameter predicts double-lumen tube size: a method for selecting left double-lumen tubes. Anesth Analg. 1996;82:861–4.
Chow MY, Liam BL, Lew TW, Chelliah RY, Ong BC. Predicting the size of a double-lumen endobronchial tube based on tracheal diameter. Anesth Analg. 1998;87:158–60.
Amar D, Desiderio DP, Heerdt PM, et al. Practice patterns in choice of left double-lumen tube size for thoracic surgery. Anesth Analg. 2008;106:379–83.
Eberle B, Weiler N, Vogel N, Kauczor HU, Heinrichs W. Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size. J Cardiothorac Vasc Anesth. 1999;13:532–7.
Campos JH. Update on tracheobronchial anatomy and flexible fiberoptic bronchoscopy in thoracic anesthesia. Curr Opin Anaesthesiol. 2009;22:4–10.
Brodsky JB, Benumof JL, Ehrenwerth J, Ozaki GT. Depth of placement of left double-lumen endobronchial tubes. Anesth Analg. 1991;73:570–2.
Boucek CD, Landreneau R, Freeman JA, Strollo D, Bircher NG. A comparison of techniques for placement of double-lumen endobronchial tubes. J Clin Anesth. 1998;10:557–60.
Campos JH. How to achieve successful lung separation. SAJAA. 2008;14:22–6.
Cavus E, Kieckhaefer J, Doerges V, et al. The C-MAC videolaryngoscope: first experiences with a new device for videolaryngoscopy-guided intubation. Anesth Analg. 2010 Feb;110:473–7.
Purugganan RV, Jackson TA, Heir JS, et al. Video laryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation: a retrospective analysis. J Cardiothorac Vasc Anesth. 2012;26:845–8.
Russell T, Slinger P, Roscoe A, et al. A randomised controlled trial comparing the GlideScope(®) and the Macintosh laryngoscope for double-lumen endobronchial intubation. Anaesthesia. 2013;68:1253–8.
Chastel B, Perrier V, Germain A, et al. Usefulness of the Airtraq DL™ videolaryngoscope for placing a double-lumen tube. Anaesth Crit Care Pain Med. 2015;34:89–93.
Brodsky JB, Lemmens HJ. Left double-lumen tubes: clinical experience with 1,170 patients. J Cardiothorac Vasc Anesth. 2003;17:289–98.
Benumof JL, Partridge BL, Salvatierra C, Keating J. Margin of safety in positioning modern double-lumen endotracheal tubes. Anesthesiology. 1987;67:729–38.
McKenna MJ, Wilson RS, Botelho RJ. Right upper lobe obstruction with right-sided double-lumen endobronchial tubes: a comparison of two tube types. J Cardiothorac Anesth. 1988;2:734–40.
Campos JH, Gomez MN. Pro: right-sided double-lumen endotracheal tubes should be routinely used in thoracic surgery. J Cardiothorac Vasc Anesth. 2002;16:246–8.
Bussières JS, Lacasse Y, Côté D, et al. Modified right-sided Broncho-Cath® double lumen tube improves endobronchial positioning: a randomized study. Can J Anaesth. 2007;54:276–82.
Stene R, Rose M, Weinger MB, Benumof JL, Harrell J. Bronchial trifurcation at the carina complicating use of a double-lumen tracheal tube. Anesthesiology. 1994;80:1162–3.
Ehrenfeld JM, Walsh JL, Sandberg WS. Right- and left-sided Mallinckrodt double-lumen tubes have identical clinical performance. Anesth Analg. 2008;106:1847–52.
Campos JH, Hanada S. DLT with incorporated fiberoptic bronchoscopy. Chapter 116. In: Rosenblatt WH, Popescu WM, editors. Master techniques in upper and lower airway management: Wolters Kluwer Health; 2015. p. 250–1.
Saracoglu A, Saracoglu KT. VivaSight: a new era in the evolution of tracheal tubes. J Clin Anesth. 2016;33:442–9.
Heir JS, Purugganan R, Jackson TA, et al. A retrospective evaluation of the use of video-capable double-lumen endotracheal tubes in thoracic surgery. J Cardiothorac Vasc Anesth. 2014;28:870–2.
Massot J, Dumand-Nizard V, Fischler M, et al. Evaluation of the double-lumen tube vivasight-DL (DLT-ETView): a prospective single-center study. J Cardiothorac Vasc Anesth. 2015;29:1544–9.
Levy-Faber D, Malyanker Y, Nir RR, et al. Comparison of VivaSight double-lumen tube with a conventional double-lumen tube in adult patients undergoing video-assisted thoracoscopic surgery. Anaesthesia. 2015;70:1259–63.
Klein U, Karzai W, Bloos F, et al. Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia: a prospective study. Anesthesiology. 1998;88:346–50.
Sherry K. Management of patients undergoing oesophagectomy. In: Gray AJG, Hoile RW, Ingram GS, Sherry K, editors. The report of the national confidential enquiry into perioperative deaths 1996/1997. London: NCEPOD; 1998. p. 57–61.
Pennefather SH, Russell GN. Placement of double lumen tubes – time to shed light on an old problem. Br J Anaesth. 2000;84:308–10.
Seymour AH, Prasad B, McKenzie RJ. Audit of double-lumen endobronchial intubation. Br J Anaesth. 2004;93:525–7.
Slinger P. A view of and through double-lumen tubes. J Cardiothorac Vasc Anesth. 2003;17:287–8.
Campos JH, Hallam EA, Van Natta T, Kernstine KH. Devices for lung isolation used by anesthesiologists with limited thoracic experience: comparison of double-lumen endotracheal tube, Univent torque control blocker, and Arndt wire-guided endobronchial blocker. Anesthesiology. 2006;104:261–6.
de Bellis M, Accardo R, Di Maio M, et al. Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery? Eur J Cardiothorac Surg. 2011;40:912–6.
Lohser J, Brodsky JB. Silbronco double-lumen tube. J Cardiothorac Vasc Anesth. 2006;20:129–31.
Hagihira S, Takashina M, Mashimo T. Application of a newly designed right-sided, double-lumen endobronchial tube in patients with a very short right mainstem bronchus. Anesthesiology. 2008;109:565–8.
Ghosh S, Falter F, Goldsmith K, Arrowsmith JE. The Papworth BiVent tube: a new device for lung isolation. Anaesthesia. 2008;63:996–1000.
Ghosh S, Klein AA, Prabhu M, Falter F, et al. The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers. Br J Anaesth. 2008;101:424–8.
Saito S, Dohi S, Naito H. Alteration of double-lumen endobronchial tube position by flexion and extension of the neck. Anesthesiology. 1985;62:696–7.
Yüceyar L, Kaynak K, Cantürk E, Aykaç B. Bronchial rupture with a left-sided polyvinylchloride double-lumen tube. Acta Anaesthesiol Scand. 2003;47:622–5.
Liu H, Jahr JS, Sullivan E, Waters PF. Tracheobronchial rupture after double-lumen endotracheal intubation. J Cardiothorac Vasc Anesth. 2004;18:228–33.
Benumof JL, Wu D. Tracheal tear caused by extubation of a double-lumen tube. Anesthesiology. 2002;97:1007–8.
Sucato DJ, Girgis M. Bilateral pneumothoraces, pneumomediastinum, pneumoperitoneum, pneumoretroperitoneum, and subcutaneous emphysema following intubation with a double-lumen endotracheal tube for thoracoscopic anterior spinal release and fusion in a patient with idiopathic scoliosis. J Spinal Disord Tech. 2002;15:133–8.
Weng W, DeCrosta DJ, Zhang H. Tension pneumothorax during one-lung ventilation: a case report. J Clin Anesth. 2002;14:529–31.
Fitzmaurice BG, Brodsky JB. Airway rupture from double-lumen tubes. J Cardiothorac Vasc Anesth. 1999;13:322–9.
Knoll H, Ziegeler S, Schreiber JU, et al. Airway injuries after one-lung ventilation: a comparison between double-lumen tube and endobronchial blocker: a randomized, prospective, controlled trial. Anesthesiology. 2006;105:471–7.
Clayton-Smith A, Bennett K, Alston RP, et al. A comparison of the efficacy and adverse effects of double-lumen endobronchial tubes and bronchial blockers in thoracic surgery: a systematic review and meta-analysis of randomized controlled trials. J Cardiothorac Vasc Anesth. 2015;29:955–66.
Falzon D, Alston RP, Coley E, et al. Lung isolation for thoracic surgery: from inception to evidence-based. J Cardiothorac Vasc Anesth. 2017;31:678–93.
Park SH, Han SH, Do SH, et al. Prophylactic dexamethasone decreases the incidence of sore throat and hoarseness after tracheal extubation with a double-lumen endobronchial tube. Anesth Analg. 2008;107:1814–8.
Campos JH. Effects of oxygenation during selective lobar versus total lung collapse with or without continuous positive airway pressure. Anesth Analg. 1997;85:583–6.
Campos JH, Ledet C, Moyers JR. Improvement of arterial oxygen saturation with selective lobar bronchial block during hemorrhage in a patient with previous contralateral lobectomy. Anesth Analg. 1995;81:1095–6.
Amar D, Desiderio DP, Bains MS, Wilson RS. A novel method of one-lung isolation using a double endobronchial blocker technique. Anesthesiology. 2001;95:1528–30.
Espà C, GarcÃa-Guasch R, Ibáñez C, Fernández E, Astudillo J. Selective lobar blockade using an Arndt endobronchial blocker in 2 patients with respiratory compromise who underwent lung resection. Arch Bronconeumol. 2007;43:346–8.
Ng JM, Hartigan PM. Selective lobar bronchial blockade following contralateral pneumonectomy. Anesthesiology. 2003;98:268–70.
Hagihira S, Maki N, Kawaguchi M, Slinger P. Selective bronchial blockade in patients with previous contralateral lung surgery. J Cardiothorac Vasc Anesth. 2002;16:638–42.
Campos JH. Update on selective lobar blockade during pulmonary resections. Curr Opin Anaesthesiol. 2009;22:18–22.
Campos JH. Which device should be considered the best for lung isolation: double-lumen endotracheal tube versus bronchial blockers. Curr Opin Anaesthesiol. 2007;20:27–31.
Mourisse J, Liesveld J, Verhagen A, et al. Efficiency, efficacy, and safety of EZ-blocker compared with left-sided double-lumen tube for one-lung ventilation. Anesthesiology. 2013;118:550–61.
Kus A, Hosten T, Gurkan Y, et al. A comparison of the EZ-blocker with a Cohen flex-tip blocker for one-lung ventilation. J Cardiothorac Vasc Anesth. 2014;28:896–9.
Hagihira S, Takashina M, Mori T, Yoshiya I. One-lung ventilation in patients with difficult airways. J Cardiothorac Vasc Anesth. 1998;12:186–8.
Baraka A. The univent tube can facilitate difficult intubation in a patient undergoing thoracoscopy. J Cardiothorac Vasc Anesth. 1996;10:693–4.
Ransom ES, Carter SL, Mund GD. Univent tube: a useful device in patients with difficult airways. J Cardiothorac Vasc Anesth. 1995;9:725–7.
Campos JH. Difficult airway and one-lung ventilation. Curr Rev Clin Anesth. 2002;22:197–208.
GarcÃa-Aguado R, Mateo EM, Tommasi-Rosso M, et al. Thoracic surgery and difficult intubation: another application of univent tube for one-lung ventilation. J Cardiothorac Vasc Anesth. 1997;11:925–6.
GarcÃa-Aguado R, Mateo EM, Onrubia VJ, Bolinches R. Use of the Univent System tube for difficult intubation and for achieving one-lung anaesthesia. Acta Anaesthesiol Scand. 1996;40:765–7.
Takenaka I, Aoyama K, Kadoya T. Use of the univent bronchial-blocker tube for unanticipated difficult endotracheal intubation. Anesthesiology. 2000;93:590–1.
Arndt GA, DeLessio ST, Kranner PW, et al. One-lung ventilation when intubation is difficult-presentation of a new endobronchial blocker. Acta Anaesthesiol Scand. 1999;43:356–8.
Arndt GA, Buchika S, Kranner PW, DeLessio ST. Wire-guided endobronchial blockade in a patient with a limited mouth opening. Can J Anaesth. 1999;46:87–9.
Grocott HP, Scales G, Schinderle D, King K. A new technique for lung isolation in acute thoracic trauma. J Trauma. 2000;49:940–2.
Byhahn C, Habler OP, Bingold TM, et al. The wire-guided endobronchial blocker: applications in trauma patients beyond mere single-lung ventilation. J Trauma. 2006;61:755–9.
Campos JH, Kernstine KH. Use of the wire-guided endobronchial blocker for one-lung anesthesia in patients with airway abnormalities. J Cardiothorac Vasc Anesth. 2003;17:352–4.
Kabon B, Waltl B, Leitgeb J, Kapral S, Zimpfer M. First experience with fiberoptically directed wire-guided endobronchial blockade in severe pulmonary bleeding in an emergency setting. Chest. 2001;120:1399–402.
Kazari W. Alternative method to deflate the operated lung when using wire-guided endobronchial blockade. Anesthesiology. 2003;99:239–40.
Campos JH. In response: an alternative method to deflate the operated lung when using wire guided endobronchial blockade. Anesthesiology. 2003;99:241.
Soto RG, Oleszak SP. Resection of the Arndt bronchial blocker during stapler resection of the left lower lobe. J Cardiothorac Vasc Anesth. 2006;20:131–2.
Campos J. Lung isolation. In: Slinger P, editor. Principles and practice of anesthesia for thoracic surgery. 1st ed. New York; London: Springer; 2011.
Roscoe A, Kanellakos GW, McRae K, Slinger P. Pressures exerted by endobronchial devices. Anesth Analg. 2007;104:655–8.
Lizuka T, Tanno M, Hamada Y, Shga T, Ohe Y. Uniblocker® bronchial blocker tube to facilitate one-lung ventilation during thoracoscopic surgery. Anesthesiology. 2007;108:A1815.
Campos JH, Kernstine KH. A structural complication in the torque control blocker Univent: fracture of the blocker cap connector. Anesth Analg. 2003;96:630–1.
Peragallo RA, Swenson JD. Congenital tracheal bronchus: the inability to isolate the right lung with a univent bronchial blocker tube. Anesth Analg. 2000;91:300–1.
Asai T. Failure of the Univent bronchial blocker in sealing the bronchus. Anaesthesia. 1999;54:97.
Thielmeier KA, Anwar M. Complication of the Univent tube. Anesthesiology. 1996;84:491.
Dougherty P, Hannallah M. A potentially serious complication that resulted from improper use of the Univent tube. Anesthesiology. 1992;77:835.
Prabhu MR, Smith JH. Use of the Arndt wire-guided endobronchial blocker. Anesthesiology. 2002;97:1325.
Sandberg WS. Endobronchial blocker dislodgement leading to pulseless electrical activity. Anesth Analg. 2005;100:1728–30.
Ueda K, Goetzinger C, Gauger EH, et al. Use of bronchial blockers: a retrospective review of 302 cases. J Anesth. 2012;26:115–7.
Honikman R, Rodriguez-Diaz CA, Cohen E. A ballooning crisis: three cases of bronchial blocker malfunction and a review. J Cardiothorac Vasc Anesth. 2017;31:1799–804.
Brodsky JB, Tobler HG, Mark JB. A double-lumen endobronchial tube for tracheostomies. Anesthesiology. 1991;74:387–8.
Saito T, Naruke T, Carney E, et al. New double intrabronchial tube (Naruke tube) for tracheostomized patients. Anesthesiology. 1998;89:1038–9.
Bellver J, GarcÃa-Aguado R, De Andrés J, ValÃa JC, Bolinches R. Selective bronchial intubation with the univent system in patients with a tracheostomy. Anesthesiology. 1993;79:1453–4.
Dhamee MS. One-lung ventilation in a patient with a fresh tracheostomy using the tracheostomy tube and a Univent endobronchial blocker. J Cardiothorac Vasc Anesth. 1997;11:124–5.
Tobias JD. Variations on one-lung ventilation. J Clin Anesth. 2001;13:35–9.
Ko R, McRae K, Darling G, et al. The use of air in the inspired gas mixture during two-lung ventilation delays lung collapse during one-lung ventilation. Anesth Analg. 2009;108:1092–6.
Yoshimura T, Ueda K, Kakinuma A, et al. Bronchial blocker lung collapse technique: nitrous oxide for facilitating lung collapse during one-lung ventilation with a bronchial blocker. Anesth Analg. 2014;118:666–70.
Campos JH, Ueda K, Hallam EA. Lung isolation in the morbidly obese patient: a comparison of a left-sided double-lumen endotracheal tube with the Arndt® wire-guided blocker. Br J Anaesth. 2012;109:630–5.
Bussières JS, Somma J, Del Castillo JL, et al. Bronchial blocker versus left double-lumen endotracheal tube in video-assisted thoracoscopic surgery: a randomized-controlled trial examining time and quality of lung deflation. Can J Anaesth. 2016;63:818–27.
Neustein SM. Pro: bronchial blockers should be used routinely for providing one-lung ventilation. J Cardiothorac Vasc Anesth. 2015;29:234–6.
Cohen E. Strategies for lung isolation: to block or not to block? Can J Anaesth. 2016;63:797–801.
Hesselfeldt R, Kristensen MS, Rasmussen LS, et al. Evaluation of the airway of the SimMan® full-scale patient simulator. Acta Anaesthesiol Scand. 2005;49:1339–45.
Wong AK. Full scale computer simulators in anesthesia training and evaluation. Can J Anaesth. 2004;51:455–64.
Nyssen AS, Larbuisson R, Janssens M, et al. A comparison of the training value of two types of anesthesia simulators: computer screen-based and mannequin-based simulators. Anesth Analg. 2002;94:1560–5.
Duffy CH, Myles PS. Review: thoracic-anesthesia.com. J Cardiothorac Vasc Anesth. 2008;22:644.
Campos JH, Hallam EA, Ueda K. Training in placement of the left-sided double lumen tube among non-thoracic anesthesiologists: intubation model simulator versus computer-based DVD, a randomized control trial. Eur J Anaesthesiol. 2011;28:169–74.
Failor E, Bowdle A, Jelacic S, et al. High-fidelity simulation of lung isolation with double-lumen endotracheal tubes and bronchial blockers in anesthesiology resident training. J Cardiothorac Vasc Anesth. 2014;28:865–9.
Latif RK, VanHorne EM, Kandadai SK, et al. Teaching basic lung isolation skills on human anatomy simulator: attainment and retention of lung isolation skills. BMC Anesthesiol. 2016;20:16:1–7.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Clinical Case Discussion
Clinical Case Discussion
Case: A 60-year-old female, weight 61 kg and is 161 cm tall, has a left lower lobe mass and is scheduled for a left lower lobectomy (Fig. 16.17a, b). She is a former smoker and the predicted value of forced expiratory volume in 1Â s (FEV1) is 75% of the predicted value. She has no significant known comorbidities and past history otherwise unremarkable (see Fig. 16.20).
Questions
-
What lung isolation device will be indicated?
-
What side and size of lung isolation device will be indicated?
-
What anatomical structures in the chest radiograph are relevant while planning the use of lung isolation devices?
-
What are the different alternatives for lung isolation devices?
-
What technique should be used to achieve optimal position of lung isolation devices?
-
What are the common problems in the intraoperative period with lung isolation devices?
-
What are the complications associated with lung isolation devices?
Focus on the Patient’s Gender, Size, Height, and Preoperative Chest Radiograph
-
To determine the lung isolation device.
-
Focus on the use of left-sided DLT for routine, uncomplicated cases or a right-sided DLT for selective cases.
-
Focus on the indication of lung isolation.
-
Knowledge of tracheobronchial anatomy and the use of flexible fiberoptic bronchoscopy to confirm device placement are essential for success on lung isolation.
-
Alternative devices for lung isolation such as bronchial blockers should be considered in specific cases.
Choice of Lung Isolation Device
-
If there is nothing in the patient’s history or physical examination to suggest the possibility of difficult airway in a left- or right-sided DLT, depending on the clinician’s preference, would be equivalent first choices to manage this case.
-
The patient’s sex and height suggest that either a 35 or 37 F DLT would be appropriate and the choice can be further refined by measuring the tracheal width on the PA chest X-ray (see Fig. 16.1).
-
In the absence of a difficult airway, the problem of intraoperative displacement with bronchial blockers makes them a second choice for lung isolation in this patient.
-
Correct positioning of the device for lung isolation should be confirmed with fiberoptic bronchoscopy.
Expected Intraoperative Problems During Lung Isolation
-
Malpositions and the potential for tracheobronchial injuries
Rights and permissions
Copyright information
© 2019 Springer Nature Switzerland AG
About this chapter
Cite this chapter
Campos, J. (2019). Lung Isolation. In: Slinger, P. (eds) Principles and Practice of Anesthesia for Thoracic Surgery. Springer, Cham. https://doi.org/10.1007/978-3-030-00859-8_16
Download citation
DOI: https://doi.org/10.1007/978-3-030-00859-8_16
Published:
Publisher Name: Springer, Cham
Print ISBN: 978-3-030-00858-1
Online ISBN: 978-3-030-00859-8
eBook Packages: MedicineMedicine (R0)