Abstract
There are two ways to identify proteins from peptide MS-MS spectra. The first is de novo interpretation of the spectrum to obtain a peptide sequence followed by BLAST searching of the sequence against a sequence database to identify the protein. This is a perfectly reasonable approach—as long as there are only a few spectra to deal with. Manual de novo interpretation of an individual MS-MS spectrum takes between half an hour and a couple of days, depending on the complexity of the spectrum and the experience of the analyst. As noted earlier, some spectra do not contain complete b- or y-ion series and thus it may not be possible to unambiguously interpret a peptide sequence from these spectra. The analyst then must guess at sequence where the spectral clues fall short. Of course, accurate de novo interpretation of MS-MS spectra requires skill and experience. Nevertheless, we could easily use this approach to assign the sequences of several peptides in a sample and identify the precursor protein by BLAST searching within a day or two. This could be perfectly acceptable, for example, to identify one or two proteins from bands on an SDS gel.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
Suggested Reading
Clauser, K. R., Baker, P., and Burlingame, A. L. (1999) Role of accurate mass measurement (+/- 10 ppm) in protein identification strategies employing MS or MS/MS and database searching. Anal. Chem. 71, 2871–2882.
Yates, J. R., Eng, J. K., and McCormack, A. L. (1995) Mining genomes: correlating tandem mass spectra of modified and unmodified peptides to sequences in nucleotide databases. Anal. Chem. 67, 3202–3210.
Yates, J. R., Eng, J. K., McCormack, A. L., and Schieltz, D. (1995) Method to correlate tandem mass spectra of modified peptides to amino acid sequences in the protein database. Anal. Chem. 67, 1426–1436.
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer Science+Business Media New York
About this chapter
Cite this chapter
Liebler, D.C. (2002). Protein Identification with Tandem Mass Spectrometry Data. In: Introduction to Proteomics. Humana Press, Totowa, NJ. https://doi.org/10.1007/978-1-59259-130-5_9
Download citation
DOI: https://doi.org/10.1007/978-1-59259-130-5_9
Publisher Name: Humana Press, Totowa, NJ
Print ISBN: 978-0-89603-992-6
Online ISBN: 978-1-59259-130-5
eBook Packages: Springer Book Archive