The accuracy and reproducibility of radio-thin layer chromatography (RTLC) of radiochemicals in biological fluids was investigated using a RITA 6800 analyzer. When applications were made in a simple matrix (water) with no elution of the plate the accuracy of RTLC was comparable with liquid scintillation counting (LSC). However at low loadings (92 dpm) the standard deviations were more than ten times greater with RTLC than LSC. With spots of approximately 2mm in diameter the position of the detector wire was not critical (± 3mm). Increasing concentrations of biological fluids decreased the number of counts obtained. This was probably caused by a change in the spatial distribution of the radiochemical in the silica. Absorption of the radioactivity by constituents of the biological fluid was not an important factor.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. S. D. Shulman, J.Liq.Chromatogr., 6:35 (1983).

    Article  CAS  Google Scholar 

  2. R. Stevenson, Amer.Lab., 49 May (1970).

    Google Scholar 

  3. H. Filthuth, Ind.Res.Dev., 23:140 (1981).

    CAS  Google Scholar 

  4. H. Filthuth, Git.Fachz.Lab., 28:870 (1984).

    CAS  Google Scholar 

  5. S. Ebel, E. Glaser and D. Rost, High Resolut.Chromatogr.Chromatogr Commun., 1:250 (1978).

    Article  CAS  Google Scholar 

  6. S. J. Constanzo and M. J. Cardone, J.Liq.Chromatogr., 7:2711 (1984).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1988 Springer Science+Business Media New York

About this chapter

Cite this chapter

Dallas, F.A.A., Halliday, T.J., Saynor, D.A. (1988). The Accuracy and Reproducibility of Radio-Thin Layer Chromatography Measurements of Drugs in Biological Fluids. In: Dallas, F.A.A., Read, H., Ruane, R.J., Wilson, I.D. (eds) Recent Advances in Thin-Layer Chromatography. Springer, Boston, MA. https://doi.org/10.1007/978-1-4899-2221-2_9

Download citation

  • DOI: https://doi.org/10.1007/978-1-4899-2221-2_9

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4899-2223-6

  • Online ISBN: 978-1-4899-2221-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics