Conceptual Design for an Epithermal-Neutron Beam for Boron Neutron Capture Therapy at the Georgia Institute of Technology Research Reactor

  • Kathleen A. Klee
  • Ratib A. Karam

Abstract

Exceptional beam quality is very important to the success of Boron Neutron Capture Therapy (BNCT). In this work we completed a conceptual filter design which provides an epi-thermal neutron beam at the Georgia Tech Research Reactor (GTRR) suitable for BNCT application. Both Monte Carlo (MCNP) and discrete ordinate (ANISN, DORT) based computer codes were used in the filter design and parameter optimization process. The in-vessel portion of this filter, located between the core and the bio-medical facility port, is composed of a series of circular aluminum plates in D2O surrounded by air-filled toroidal aluminum tubing. The tubing increases the buoyancy of the filter structure, reducing the stress placed on the reactor vessel. The ex-vessel filter, located in the existing bio-medical facility port, consists of a series of dry aluminum plates, lithiated aluminum plates, a plate of titanium and a bismuth lead gamma shield in a cadmium housing. The remainder of the cone is void, increasing beam collimation. The integrated epi-thermal neutron flux of 2.5×109 n/cm2/s will keep treatment fractions less than 30 minutes. Both the fast neutron and gamma KERMAs are less than 2×10−11 cGy/n/cm2, allowing the therapeutic dose to be reached before the healthy tissue tolerance is exceeded from background radiations. The current to flux ratio of 0.86 is also excellent for BNCT application. The results show that the GTRR is capable of producing one of the best neutron sources for BNCT application in the United States. Plans to install the filter in the GTRR continue to move forward.

Keywords

Boron Neutron Capture Therapy Thermal Neutron Flux Epithermal Neutron Exit Port Beam Port 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    H. Hatanaka, et. al., “New Dimensions of Boron-Thermal Neutron Capture Therapy (BNCT) in Neurosurgery”, Advances in Neutron Capture Therapy,R. Barth, and A. Soloway (Editors), Plenum Press, New York, NY, (665–670)1993.Google Scholar
  2. 2.
    Y. Mishima, et. al., “Recent Advances in the Application of Selective Melanoma Neutron Capture Therapy for Treatment of Facial Lentigo Maligna and of Lymph Node Metastases from Aeral Lentiginous Melanoma”, Advances in Neutron Capture Therapy,R. Barth, and A. Soloway (Editors), Plenum Press, New York, NY, (705–710)1993.Google Scholar
  3. 3.
    F.J. Wheeler, et. al., “Epithermal-Neutron Beam Design for Neutron Capture Therapy at the PBF and BMRR Reactor Facilities”, Nue!. Technol., 92: 106–117 (1990).Google Scholar
  4. 4.
    D. W. Nigg and F.J. Wheeler, “Conceptual Physics Design for an Epithermal-Neutron Beam at the Georgia Institute of Technology Research Reactor”, Trans. ANS, 65: 146 (1992).Google Scholar
  5. 5.
    W. A. Rhoades and R. L. Childs, “An Updated Version of the DOT-4 One-and ”I’wo-Dimensional Neutron/Photon Transport Code“, ORNL-5851, Oak Ridge National Laboratory (1982).Google Scholar
  6. 6.
    W. A. Rhoades and R.L. Childs, “The TORT Three-Dimensional Discrete-Ordinates Neutron/Photon Transport Code”, ORNL-6268, Oak Ridge National Laboratory (1987).Google Scholar
  7. 7.
    R. W. Roussin, “BUGLE-80 Coupled 47-Neutron, 20 Gamma-Ray, P3 Cross Section Library for LWR Shielding Calculations”, DLC-75, Radiation Shielding Information Center, Oak Ridge National Laboratory (1980).Google Scholar
  8. 8.
    D. W. Nigg, et. al., “Demonstration of Three-Dimensional Deterministic Radiation Transport Theory Dose Distribution Analysis for Boron Neutron Capture Therapy”, Medical Physics, 18: 43–53 (1991).PubMedCrossRefGoogle Scholar
  9. 9.
    J. F. Briesmeister (Editor), “MCNP - A General Monte Carlo Code for Neutron and Photon Transport, Version 3A”, LA-7396-M, Revision 2, Los Alamos National Laboratory (1986).Google Scholar
  10. 10.
    R. M. Brugger, Brookhaven National Laboratory, Private Communication, June, 1993.Google Scholar
  11. 11.
    R. Huiskamp, et. al., “Dose Effect Comparisons Between HFR and BMRR Irradiated Dogs with Respect to Healthy Tissue Tolerance”, Advances in Neutron Capture Therapy, R. Barth, and A. Soloway (Editors), Plenum Press, New York, NY, (565–570) 1993.Google Scholar
  12. 12.
    P. R. Gavin, et. al., “Canine Spontaneous Brain Tumors - A Large Animal Model for BNCT”, Strahlentherapie und Onkologie, 165: 225 (1989).PubMedGoogle Scholar

Copyright information

© Springer Science+Business Media New York 1996

Authors and Affiliations

  • Kathleen A. Klee
    • 1
  • Ratib A. Karam
    • 1
  1. 1.Georgia Institute of TechnologyAtlantaGeorgia

Personalised recommendations