On-Line Beam Monitoring for Boron Neutron Capture Therapy at the MIT Research Reactor

  • O. K. Harling
  • D. J. Moulin
  • J.-M. Chabeuf
  • G. R. Solares

Abstract

A computer-based beam monitoring system for boron neutron capture therapy is described. This system provides accurate, sensitive, and rapid on-line readout and recording of the beam components, epithermal and thermal neutron flux, and gamma ray dose rate. Readout of fluxes, fluentes, and corresponding doses in the target are provided in color coded graphic as well as numerical form on the computer monitors. Redundancy of fluence measurement is provided by an independent system using scalers and timers and by utilizing reactor power measuring instruments. Variations in neutron spectrum or spatial distribution of the beam can be rapidly diagnosed with the aid of the monitor readout.

Keywords

Thermal Neutron Neutron Detector Boron Neutron Capture Therapy Epithermal Neutron Prompt Gamma Activation Analysis 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    O. K. Harting, R. D. Rogus, J.-M. Chabeuf, S. C. Yarn, F. Lambert, J. C. Yanch, R. G. Zamenhof, G. Solares, D. E. Wazer, and H. Madoc-Jones, Preparations for clinical trials at the MIT Reactor and the New England Medical Center,“ in: ”Advances in Neutron Capture Therapy,“ A. H. Soloway, R. F. Barth and D. E. Carpenter, eds., Plenum Press, New York, 1993, pp. 753–756.CrossRefGoogle Scholar
  2. 2.
    D. J. Moulin, “On-line dosimetry for clinical trials of neutron capture therapy,” S.M. Thesis, Department of Nuclear Engineering, Massachusetts Institute of Technology, September 1991.Google Scholar
  3. 3.
    J.-M. N. Chabeuf, “Design and construction of a prompt gamma activation analysis facility and improvement of the on-line beam monitor system for the medical beam at the MITR-I1,” M.S. Thesis, Department of Nuclear Engineering, Massachusetts Institute of Technology, January, 1993.Google Scholar
  4. 4.
    LabView 2 user manual, National Instruments Corporation, Austin, Texas.Google Scholar
  5. 5.
    R. Zamenhof, J. Brenner. J. Yanch, D. Wazer, H. Madoc-Jones, S. Saris, and O. Harting, Treatment planning for neutron capture therapy of glioblastoma multiforme using an epithermal neutron beam from the MITR-II Research Reactor and Monte Carlo simulation,“ in: ”Progress in Neutron Capture Therapy for Cancer,“ B. J. Allen, S. W. Moore and B. V. Harrington, eds., Plenum Press, New York, 1992, pp. 173–177.CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media New York 1996

Authors and Affiliations

  • O. K. Harling
    • 1
  • D. J. Moulin
    • 1
  • J.-M. Chabeuf
    • 1
  • G. R. Solares
    • 1
  1. 1.Nuclear Reactor LaboratoryMassachusetts Institute of TechnologyCambridgeUSA

Personalised recommendations