Operation Characteristics of the Helium Refrigerator for the Large Helical Device with a Dummy Load Apparatus

  • Chapter
Advances in Cryogenic Engineering

Abstract

The helium refrigerator/liquefier operation for the Large Helical Device (LHD) with a dummy load apparatus (DLA) has been conducted under four different refrigeration conditions: no heat load mode; precooling mode; steady state mode and extra heat input mode. The stable operation of each mode, which simulates the refrigeration requirements for the LHD, was successfully demonstrated under semi-automatic control of the refrigerator. To establish the sequential control of the system, historical and real time trends of PID controlled electro-pneumatic actuators for valves and its corresponding thermal-hydraulic behavior of helium gas in the refrigeration system were collected as a data base. According to the operating experiences, the instabilities in the refrigeration system were observed. These instability mechanisms are considered to be quite complex: they are assumed to be coupled and/or combinations of heat exchangers in the refrigerator with approximately 90 to 100 m long supercritical helium hydraulic paths. To suppress these instabilities, adjustments of PID controlled valves and modifications of pressure control for the compressors were conducted. The paper describes operation characteristics of the helium refrigerator/liquefier with a DLA. The instabilities in the refrigeration system are also discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. S Satoh, et al., “Construction and Commissioning Tests of a 10 kW Class Helium Refrigerator for the Large Helical Device,” Adv. Cryo. Engr., 41A: 727(1996).

    Article  CAS  Google Scholar 

  2. R. Maekawa et al., “Study of Optimum Operating Condition for the Helium Refrigeration System of the LHD with a Dummy Load Apparatus,” Proc. ICEC16, 1:87(1997).

    CAS  Google Scholar 

  3. T. Mito et al., “Cryogenic Control System for the Large Helical Device,” Proc. ICEC16, 1:79(1997).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1998 Springer Science+Business Media New York

About this chapter

Cite this chapter

Maekawa, R. et al. (1998). Operation Characteristics of the Helium Refrigerator for the Large Helical Device with a Dummy Load Apparatus. In: Kittel, P. (eds) Advances in Cryogenic Engineering. Advances in Cryogenic Engineering, vol 43. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-9047-4_70

Download citation

  • DOI: https://doi.org/10.1007/978-1-4757-9047-4_70

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4757-9049-8

  • Online ISBN: 978-1-4757-9047-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics