Skip to main content

Measurement of Heat Conduction through Stacked Screens

  • Chapter
Advances in Cryogenic Engineering

Part of the book series: Advances in Cryogenic Engineering ((ACRE,volume 43))

Abstract

This paper describes the experimental apChapautus for the measurement of heat conduction through stacked screens as well as some experimental results taken with the apChapautus. Screens are stacked in a fiberglass-epoxy cylinder, which is 24.4 mm in diameter and 55 mm in length. The cold end of the stacked screens is cooled by a Gifford-McMahon (GM) cryocooler at cryogenic temperature, and the hot end is maintained at room temperature. Heat conduction through the screens is determined from the temperature gradient in a calibrated heat flow sensor mounted between the cold end of the stacked screens and the GM cryocooler. The samples used for these experiments consisted of 400-mesh stainless steel screens, 400-mesh phosphor bronze screens, and two different porosities of 325-mesh stainless steel screens. The wire diameter of the 400-mesh stainless steel and phosphor bronze screens was 25.4 μm and the 325-mesh stainless steel screen wire diameters were 22.9 urn and 27.9 μm. Standard porosity values were used for the experimental data with additional porosity values used on selected experiments. The experimental results showed that the helium gas between each screen enhanced the heat conduction through the stacked screens by several orders of magnitude compared to that in vacuum. The conduction degradation factor is the ratio of actual heat conduction to the heat conduction where the regenerator material is assumed to be a solid rod of the same cross-sectional area as the metal fraction of the screen. This factor was about 0.1 for the stainless steel and 0.022 for the phosphor bronze, and almost constant for the temperature range of 40 to 80 K at the cold end.

Contribution of the National Institute of Standards and Technology, not subject to copyright in the U.S.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Walker, G., Cry coolers, Plenum Press, New York (1983)

    Google Scholar 

  2. Organ, A. J., “Conductivity for quantifying regenerator thermal shorting,” to be published.

    Google Scholar 

  3. Lee, A.C., “Contact resistance of 500 mesh regenerator screens,” Cryogenics, Vol 34, No. 5 (1994), pp. 451–456.

    Article  Google Scholar 

  4. Schumann, T.E.W., and Voss, V., “Heat Flow Through Granulated Material,” Fuel, Vol. 13 (1934), pp. 249–256.

    CAS  Google Scholar 

  5. Takeno., “Thermal and Mechanical Properties of Advanced Cryogenic Materials at Low Temperatures,” Cryogenic Engineering, Journal of the Cryogenic Society of Japan, Vol. 12, No. 3 (1986), pp. 182–187.

    Article  Google Scholar 

  6. Gary, J., Daney, D.E., and Radebaugh, R., “A Computational Model for a Regenerator,” Proc. Third Cryocooler Conference, NBS Special Publication 698, (1985), p. 199.

    CAS  Google Scholar 

  7. Gary, J. and Radebaugh, R., “An Improved Numerical Model for Calculation of Regenerator Performance (REGEN3.1),” Proc. Fourth Interagency Meeting on Cryocoolers, David Taylor Research Center, Report DTRC-91/003, (1991), p. 165.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1998 Springer Science+Business Media New York

About this chapter

Cite this chapter

Lewis, M.A., Kuriyama, T., Kuriyama, F., Radebaugh, R. (1998). Measurement of Heat Conduction through Stacked Screens. In: Kittel, P. (eds) Advances in Cryogenic Engineering. Advances in Cryogenic Engineering, vol 43. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-9047-4_202

Download citation

  • DOI: https://doi.org/10.1007/978-1-4757-9047-4_202

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4757-9049-8

  • Online ISBN: 978-1-4757-9047-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics