Part of the book series: The International Cryogenics Monograph Series ((INCMS))

  • 112 Accesses

Abstract

There are two distinct ways of designing a cryostat for work at very low temperatures, which we shall take as meaning liquid-helium temperature, leaving the reader to make the appropriate simplifications for himself if he is working at higher temperatures. For straightforward experiments there may be a case for enclosing a container for liquid helium in a radiation shield and an outer vessel within which a high vacuum can be maintained. (See Croft and Thomas1 for a small-scale cryostat built on this principle.) However, most experimental work at low temperatures is so complicated that it is usual to use a separate metal dewar vessel which can be raised up round the complete experimental assembly so that the latter is readily accessible when setting up experiments. The design requirements of such vessels are basically similar to those for the storage vessels described in Chapter 2, but low evaporation rate has to take second place to demands set by the experimental apparatus and its environment. For example, the neck tube has to be wide enough to pass over whatever is to be submerged in liquid helium and its length is usually determined by the distance between the floor and the ceiling of the laboratory — unless it happens that a pit can be made in the floor. (This point should be remembered in laboratory design; a 10-ft ceiling height can be a serious limitation.)

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Croft, A. J., and Thomas, J. O., Cryogenics 9, 57 (1969).

    Article  Google Scholar 

  2. Roberts, V., J. Sci. Instr. 31, 251 (1954).

    Article  Google Scholar 

  3. Vos, J. E., and Kingma, R., Cryogenics 7, 50 (1967).

    Article  Google Scholar 

  4. Thomas, J. O., Acta Crystallographica, in preparation.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 1970 Springer Science+Business Media New York

About this chapter

Cite this chapter

Croft, A.J. (1970). Cryostat Dewars. In: Cryogenic Laboratory Equipment. The International Cryogenics Monograph Series. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-4893-2_8

Download citation

  • DOI: https://doi.org/10.1007/978-1-4757-4893-2_8

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4757-4895-6

  • Online ISBN: 978-1-4757-4893-2

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics