Abstract
Structural replacement of amputated limbs has been common for hundreds, even thousands, of years (1). However, the concept of restoring more than the lost structure and supporting musculature, for example, the lost sensory information, is relatively new. Even newer is the idea of using a fluid to transmit tactile information, rather than the more traditional transducers (e.g., strain gauges mounted on cables or various other parts of the terminal device). To use a fluid for this purpose increases the scope and potential for accessing sensory information. That is, the acquisition and transmission of such quantities as heat, prehensile slippage and/or prehensile forces (pressure and shear) is greatly simplified. On this basis, a new type of terminal device for an upper-extremity amputee has been designed and is described below. The device will allow fluids to act as the medium for the transmission of sensory feedback information to the prosthetic wearer. It also introduces a push/pull mode of operation which incorporates a versatile, previously unavailable, wrist mechanism.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Friedman, L.W., “Amputations and Prostheses in Primitive Cultures,” Bulletin of Prosthetics Research, Vol. 10–17, 1972, pp. 105–138.
Alpenfels, E.J., “The Anthropology and Social Significance of the Human Hand,” Artificial Limbs, Vol. 2, 1955, pp. 4–21.
Siehlow, K., “Phantom Controlled Electre Prothesis for BE and AE Amputees,” Translated from Orthopedic Technic, Number 3, 1951.
Beeker, T.W., During, J., and DenHertob, A., “Artificial Touch in a Hand Prosthesis,” Medical and Biological Engineering, Vol. 5, 1967, pp. 47–49.
Pfeiffer, E.A., Rhode, C.M., and Fabric, S.J., “An Experimental Device to Provide Substitute Tactile Sensation From the Anaesthetic Hand,” Medical and Biological Engineering, Vol. 7, 1969, pp. 191–199.
Alles, D.S., “Kinesthetic Feedback System For Amputees Via the Tactile Sense,” presented at the Second Canadian Medical and Biological Engineering Conferences, Toronto, 1968.
Alles, D.S., “Information Transmission by Phantom Sensations,” IEEE Transactions on Man-Machine Systems, Vol. MMS-11, 1970.
Mann, R.W. and Reimer, S.D., “Kinesthetic Sensation for the EMG Controlled ‘Boston Arm,’” IEEE Transactions on Man-Machine Systems, Vol. MMS-11, 1970, pp. 110–115.
Kawamura, Z. and Sueda, 0., “Sensory Feedback Device for the Artificial Arm,” monograph presented at the Fourth Pan-Pacific Rehabilitation Conference, 1969.
Davis, R.B., and Schneck, D.J., “Design of a Center Push/Pull Terminal Device and Quantitative Evaluation Technique For An Upper Extremity Prosthetic Limb,” Virginia Polytechnic Institute and State University Technical Report, #VPI-E-79–8, January, 1979, Available NTIS, Accession # PB 290 783/AS.
Mason, C.P., “Design of a Powered Arm System for the Above-Elbow Amputee,” Bulletin of Prosthetics Research, Vol. 10–18, 1972, pp. 10–24
Napier, J.R., “The Prehensile Movements of the Human Hand,” Journal of Bone and Joint Surgery, Vol. 38B, 1956, pp. 902–913.
Taylor, C.L. and Schwartz, R.J., “The Anatomy and Mechanics of the Human Hand,” Artificial Limbs, Vol. 2, 1955, pp. 22–35.
Taylor, C.L., “The Biomechanics of the Normal and of the Amputated Upper Extremity,” Human Limbs and Their Substitutes eds. Klopsteg, P.E. and Wilson, P.D., Hafner Publishing Company, New York, 1968, pp. 169–221.
Davis, R.B., notes from research at Duke University, 1976, unpublished.
Sanschi, W.R., ed., Manual of Upper-Extremity Prosthetics Department of Engineering, University of California at Los Angeles, 1958, pp. 42–44.
Fletcher, M.J., “New Developments in Hands and Hooks,” Human Limbs and Their Substitutes eds. Klopsteg, P. E. and Wilson, P.D., Hafner Publishing Company, New York, 1968, pp. 222–238.
Childress, D.S., “Neural Organization and Myoelectric Control,” Neural. Organization and Its Relevance to Prosthetics ed. Fields, W.S., Symposia Specialists, Miami, 1973, pp. 117–126.
Childress, D.S., Holmes, D.W., and Billock, J.N., “Ideas on Myoelectric Prosthetic Systems for Upper Exremity Amputees,” The Control of Upper Extremity Prostheses and Orthoses, eds. Herberts, P., Kadefors, R., Magnusson, R., and Peterson, I., Thomas Books, Springfield, Illinois, 1974, pp. 86–106.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1980 Springer Science+Business Media New York
About this chapter
Cite this chapter
Davis, R.B., Schneck, D.J. (1980). A Fluid Mechanics Approach to the Problem of Sensory Feedback in Prosthetic Devices. In: Schneck, D.J. (eds) Biofluid Mechanics · 2. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-4610-5_8
Download citation
DOI: https://doi.org/10.1007/978-1-4757-4610-5_8
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4757-4612-9
Online ISBN: 978-1-4757-4610-5
eBook Packages: Springer Book Archive