Radionuclide Generators

  • Gopal B. Saha

Abstract

The use of short-lived radionuclides has grown considerably, because larger dosages of these radionuclides can be administered to the patient with only minimal radiation dose and produce excellent image quality. This increasing appreciation of short-lived radionuclides has led to the development of radionuclide generators that serve as convenient sources of their production. A generator is constructed on the principle of the decay-growth relationship between a long-lived parent radionuclide and its short-lived daughter radionuclide. The chemical property of the daughter nuclide must be distinctly different from that of the parent nuclide so that the former can be readily separated. In a generator, basically a long-lived parent nuclide is allowed to decay to its short-lived daughter nuclide and the latter is then chemically separated. The importance of radionuclide generators lies in the fact that they are easily transportable and serve as sources of short-lived radionuclides in institutions far from the site of a cyclotron or reactor facility.

Keywords

Column Generator Methyl Ethyl Ketone Isomeric Transition Daughter Nuclide Sodium Thiosulfate Solution 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References and Suggested Reading

  1. Baker RJ. A system for routine production of concentrated technetium-99m by solvent extraction of molybdenum. Int J Appl Radiat hot. 1971; 22:483.CrossRefGoogle Scholar
  2. Colombetti LG. Radionuclide generators. In: Rayudu GVS, ed. Radiotracers for Medical Applications. Boca Raton, Fla: CRC Press; 1983:133.Google Scholar
  3. Eckelman WC, Coursey BM, eds. Technetium-99m: generators, chemistry and preparation of radiopharmaceuticals. Int J Appl Radiat hot. 1982; 33:793.Google Scholar
  4. Guillaume M, Brihaye C. Generators for short-lived gamma and positron emitting radionuclides: Current status and prospects. Nucl Med Biol. 1986; 13:89.Google Scholar
  5. Holland ME, Deutsch E, Heineman HR. Studies on commercially available 99Mo/ 99mTc radionuclide generators: I. Comparison of five analytical procedures for determination of total technetium in generator eluants. Appl Radiat hot. 1986; 37:165.CrossRefGoogle Scholar
  6. Holland ME, Deutsch E, Heineman HR. Studies on commercially available 99Mo/ 99mTc radionuclide generators: II. Operating characteristics and behavior of 99Mo/99mTc generators. Appl Radiat hot. 1986; 37:173.CrossRefGoogle Scholar
  7. Knapp FF, Jr, Butler TA, eds. Radionuclide Generators: New Systems for Nuclear Medicine Applications. American Chemical Society. Advances in chemistry series, No. 241. Washington, DC: Am Chem Soc, 1984.Google Scholar
  8. Lambrecht RM, Sajjad M. Accelerator-derived radionuclide generators. Radiochim Acta. 1988; 43:171.Google Scholar
  9. Lamson ML III, Kirschner AS, Hotte CE, et al. Generator-produced 99mTcO4-: carrier free? J Nucl Med. 1975; 16:639.PubMedGoogle Scholar
  10. Noronha OPD, Sewatkar AB, Ganatra RD, et al. Fission-produced 99Mo-99mTc generator system for medical use. J Nucl Biol Med. 1976; 20:32.PubMedGoogle Scholar
  11. Richards P, O’ Brien MJ. Rapid determination of 99Mo in separated 99mTc. J Nucl Med. 1964; 10:871.Google Scholar
  12. Saha GB, Go RT, Maclntyre WJ, et al. Use of the 82Sr/82Rb generator in clinical PET studies. Nucl Med Biol. 1990; 17:763.Google Scholar
  13. U.S. Pharmacopeia XXVIII. Rockville, MD: United States Pharmacopeial Convention; 1996.Google Scholar
  14. Yano Y, Anger HO. A gallium-68 positron cow for medical use. J Nucl Med. 1964; 5:485.Google Scholar