We have built a Bragg imaging system using carefully designed cylindrical and spherical lenses essentially free of spherical aberrations. We are particularly interested in applying the system to medical applications and have therefore restricted ourselves to low frequencies of ultrasound (1–5 MHz). The system has been used to obtain transmitted and reflected images. In addition to images, quantitative data on the light intensity in the image as a function of sound intensity have been obtained, Engineering data on the optical mounting and transducer are also discussed.
The experience gained so far leads us ti believe that a well designed system will yield useful medical images.
Keywords
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
A. Korpel, “Visualization of the cross section of a sound beam by Bragg diffraction of laser light,” Appl. Phys. Letters 9(12): 425–427 (1966)
A.’Korpel, “Optical image of ultrasonic fields by acoustic Bragg diffraction,” Ph.D> dissertation, Ùniversity of Delft, Netherlands (1969).
R.A. Smith, G. Wade, J. Powers, 3. Landry, “Studies of resolution in a Bragg imaging system,” J. Acoust. Soc. Amer. 49: 1062–1068 (1971)
J. Landry, H. Keyani, G. Wade, “Bragg-diffraction imaging: a potential technique for medical diagnosis and material inspection,” Acoustical Holography,;Vol. ÌV, Glen Wade ( Ed.) New York: Plenum Press (1972).
H. Keyani, J. Landr,y5 G. Wade, “Bragg-diffraction imaging. ‘a potential technique for medical diagnosis and material inspection, part II,” Acoustical Holography, Vol. V, Phiaip S. Green (Ed.), New York: Plenum Press (1974).
A. Korpel, “Astigmatic imaging properties of Bragg diffraction,” J. Acoust. Soc. of Amer. 49: 1059–1061 (1971).
G. Flesher and G. Wade, Personal communication, University of California, Santa Barbara, November, 1975.
American Standard Procedures for Calibration of Electra-acoustic Transducers, American Standards Association Inc., New York (1958).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1977 Springer Science+Business Media New York
About this chapter
Cite this chapter
Frieda, D., Spiegler, P., Kearly, F., Greenfield, M., Stern, R. (1977). Design Criteria for Medical Bragg Imaging. In: Kessler, L.W. (eds) Acoustical Holography. Springer, Boston, MA. https://doi.org/10.1007/978-1-4757-0653-6_26
Download citation
DOI: https://doi.org/10.1007/978-1-4757-0653-6_26
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4757-0655-0
Online ISBN: 978-1-4757-0653-6
eBook Packages: Springer Book Archive