Skip to main content

A Dual Counter X-Ray Analyzer for the Rapid Quantitative Analysis of Two-Phase Systems

  • Conference paper
Advances in X-Ray Analysis

Abstract

The normal procedure for a quantitative measurement of two phases with an X-ray diffractometer is to scan or count the intensities of two diffraction peaks and then to calculate the ratio of the two phases using an appropriate equation. This paper will describe an improved method of quantitatively measuring two phases in a sample. The diffractometer, which was constructed by Philips Electronics Instruments, consists of two fixed scintillation counters mounted at the Seeman-Bohlin focusing positions for the two desired diffraction lines. Each counter is preceded by a lithium fluoride curved crystal monochromator. The output from each counter feeds to a separate scaler which can be arranged to gate both scalers at a preselected number of counts. At this point a tape printer prints out the counts for both scalers. These counts are then related to the proportions of each phase present by an appropriate equation. Most of the electronics are solid-state designs. This paper will describe the instrumentation and show how it can be used to measure rapidly and precisely the ratio of anatase to rutile in a titanium dioxide system. The savings in time over the conventional method can be as much as 100 to 1.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. D. M. Koffman and S. H. Moll, “A Curved Crystal Monochromator for the X-Ray Diffractometer,” Norelco Reporter 11: 95, 1964.

    CAS  Google Scholar 

  2. H. H. Johann, “More Intense X-Ray Spectra Obtained with Concave Crystals,” Z. Physik 69: 185, 1931.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Gavin R. Mallett Marie J. Fay William M. Mueller

Rights and permissions

Reprints and permissions

Copyright information

© 1966 Springer Science+Business Media New York

About this paper

Cite this paper

Sanderson, B.S., MacCardle, L.E. (1966). A Dual Counter X-Ray Analyzer for the Rapid Quantitative Analysis of Two-Phase Systems. In: Mallett, G.R., Fay, M.J., Mueller, W.M. (eds) Advances in X-Ray Analysis. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-7633-0_18

Download citation

  • DOI: https://doi.org/10.1007/978-1-4684-7633-0_18

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4684-7635-4

  • Online ISBN: 978-1-4684-7633-0

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics