Skip to main content

Gas Filter Testing Methods

  • Chapter
Contamination Control and Cleanrooms

Abstract

Gas filtration of air in the cleanroom is carried out with HEPA (high- efficiency particulate air) or ULPA (ultralow penetration air) filters for ambient pressure air cleaning or with high-efficiency cartridge filters for compressed gas cleaning. Filter testing is required for both types not only to verify the performance of the filter element or filter medium proper but also to ensure the integrity of the installed filter. The ambient air filters for the cleanroom are relatively fragile and require great care in handling to avoid damage to the filter medium and the resultant leaks. The cartridge filters are not so delicate but still require care in installation to ensure that seals and O-rings are correctly installed when the cartridge is changed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Bishop, D. E., 1988. Dri-Testâ„¢: The New Way to Challenge HEPA Filters. Proceedings of the 9th International Committee of Contamination Control Societies Conference, pp. 179–182, September 26, 1988, Los Angeles.

    Google Scholar 

  • Gilmore, R. D., Mclntyre, J. A., & Petersen, G. R., 1982. Operational Experience Using Diethylhexylsebacate (DEHS) as a Challenge Test Material in Filter Testing. Proceedings of the 17th DOE/NRC Nuclear Air Cleaning Conference, pp. 821–835, July 1982, Boston.

    Google Scholar 

  • Gogins, M., et al., 1987. Design and Operation of Optimized High Efficiency Filter Element Test Systems. Proceedings of the 33d Institute of Environmental Science Annual Technical Meeting, May 1987, San Jose, CA.

    Google Scholar 

  • Gotlinsky, B., et al., 1989. Outgassing of All Metal Filters for Use in the Semiconductor Industry. Proceedings of the 35th Institute of Environmental Science Annual Technical Meeting, pp. 401–405, April 1989, Anaheim, CA.

    Google Scholar 

  • Greiner, J., 1990. HEPA Filter Leak Testing Using the Particle Counter Scan Method. CleanRooms 4(9):36–39.

    Google Scholar 

  • Gutacker, A. R., 1985. Permanent Atmospheric Background Testing for High Efficiency (HEPA) Filters and Filter Systems, Document LCCD-155. Webster, NY: ARGOT, Inc.

    Google Scholar 

  • Gutacker, A. R., 1991. Ambient Air Filtration. In Contamination Control Technologist Handbook, ed. A. Gutacker, Chapter 28. Webster, NY: ARGOT, Inc.

    Google Scholar 

  • Hinds, W. C., Macher, J. M., & First, M. W., 1983. Size Distribution of Aerosols Produced by the Laskin Aerosol Generator Using Substitute Materials for DOP. American Industrial Hygiene Association Journal 44(7):495–500.

    Article  Google Scholar 

  • Johnson, E. M., et al., 1990. A New CNC Based Automated Filter Tester for Fast Penetration Testing of HEPA and ULPA Filters and Filter Media. Proceedings of the 36th Institute of Environmental Science Annual Technical Meeting, pp. 250–256, April 1990, New Orleans.

    Google Scholar 

  • La Rocca, P. T., 1985. Testing Requirements for HEPA Filters and Clean Work Stations. Pharmaceutical Manufacturing 2(3):47–51.

    Google Scholar 

  • Laskin, S., 1948. Submerged Aerosol Unit, AEC Project Quarterly Report UR-38. Rochester, NY: University of Rochester.

    Google Scholar 

  • Rivers, R. D., & Engleman, D. S., 1984. Evaluation of a Laser Spectrometer ULPA Filter Test System. Journal of Environmental Science 27(5):31–36.

    Google Scholar 

  • Schmitz, W., & Fissan, H., 1988. Error Analysis of Penetration Ratio Measurements of ULPA Filters. Journal of Aerosol Science 19(7): 1421–1424.

    Article  Google Scholar 

  • Sinclair, C. S., & Tallentire, A., 1982. Microbiological Evaluation of Papers: The Influence of Dispersion Flow Rate on Penetration. P & MC Industry September/October:52–57.

    Google Scholar 

  • Ziemer, W., 1988. In-Situ Test of ULPA Filters. Proceedings of the 9th International Committee of Contamination Control Societies Conference, pp. 115–122, September 26, 1988, Los Angeles.

    Google Scholar 

Download references

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 1992 Van Nostrand Reinhold

About this chapter

Cite this chapter

Lieberman, A. (1992). Gas Filter Testing Methods. In: Contamination Control and Cleanrooms. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-6512-9_28

Download citation

  • DOI: https://doi.org/10.1007/978-1-4684-6512-9_28

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4684-6514-3

  • Online ISBN: 978-1-4684-6512-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics