Skip to main content

Optical Liquidborne Particle Counter Operation

  • Chapter
Contamination Control and Cleanrooms
  • 275 Accesses

Abstract

Optical liquidborne particle counters are used to characterize the concentration and size distribution of solid materials that may be suspended in liquids used in cleanroom operations. The instruments are capable of counting and sizing single particles ranging in size from approximately 0.05 μm in diameter to the millimeter size range. Particles in suspensions containing up to 50,000 particles per milliliter of liquid can be sized and counted at rates to thousands per second. As is the case with any optical particle counter, operation of the liquidborne particle counter is such that data can be accumulated with both counting and sizing errors and no indication that errors may have occurred. Errors can arise either from faulty design or construction of an OPC or from incorrect operational procedures. Operation of these devices is discussed here so that many errors can be avoided. A brief description is also given of some methods other than optical response that are commonly used for counting and sizing particles in liquid suspensions.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • American Society for Testing and Materials, 1987. Defining Size Calibration, Resolution and Counting Accuracy of Liquid-Borne Particle Counter Using Near-Monodisperse Spherical Particulate Material, ASTM F658–87, Philadelphia: American Society for Testing and Materials.

    Google Scholar 

  • Gerard, R., et al., 1988. Evaluation of the State-of-the-Art Particle Counting Methods for Ultrapure Water. Proceedings of the 9th International Committee of Contamination Control Societies Conference, September 1988, Los Angeles.

    Google Scholar 

  • Knollenberg, R. G., 1989. The Importance of Media Refractive Index in Evaluating Liquid and Surface Microcontamination Measurements. Journal of Environmental Science 30(2):50–58.

    Google Scholar 

  • Lieberman, A., 1984a. Fine Particle Characterization Methods in Liquid Suspensions. In Particle Characterization in Technology, ed. J. K. Beddow, pp. 187–232, New York: CRC Press.

    Google Scholar 

  • Lieberman, A., 1984b. Problems Associated with Submicrometre Contaminant Measurement. In Semiconductor Processing, ASTM STP 850, ed. D. C. Gupta, pp. 172–183, Philadelphia: American Society for Testing and Materials.

    Google Scholar 

  • Lieberman, A., 1986. Particle Counting in Pharmaceutical Liquids. Proceedings of the 32d Institute of Environmental Science Annual Technical Meeting, pp. 427–431, May 1986, Dallas, TX.

    Google Scholar 

  • Przybytek, J. T., & Calabrese, K. L., 1985. Measuring “Low Level” Particle Counts in Solvents. Microcontamination 3(6):51–54.

    Google Scholar 

  • Semiconductor Equipment and Materials International, 1988. Specifications for Reagents; 3.9; Calibration and Measurement Method for Particles in Liquids, SEMI Cl-88, Mountain View, CA: Semiconductor Equipment and Materials International.

    Google Scholar 

  • Verdegan, B. M., Thibodeau, L., & Stinson, J. A., 1990. Using Monodispersed Latex Spheres Dispersed in Nonpolar Liquids to Calibrate Particle Counters. Microcontamination 8(2):35–39, 64–65.

    Google Scholar 

  • Verdegan, B. M., Stinson, J. A., & Thibodeau, L., 1988. Accurate Methods for Particle Counting. Proceedings of the 43d National Conference on Fluid Power, October 11–13, 1988, Chicago.

    Google Scholar 

  • Yabe, K., et al., 1988. High Sensitivity On-Line Monitoring of Ultrapure Water for ULSI Manufacturing. Proceedings of the 9th International Committee of Contamination Control Societies Conference, pp. 509–515, September 26, 1988, Los Angeles.

    Google Scholar 

  • Yang, M., & Tolliver, D. L., 1989. Ultrapure Water Particle Monitoring for Advanced Semiconductor Manufacturing. Journal of Environmental Science 32(4):35–42.

    Google Scholar 

Download references

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 1992 Van Nostrand Reinhold

About this chapter

Cite this chapter

Lieberman, A. (1992). Optical Liquidborne Particle Counter Operation. In: Contamination Control and Cleanrooms. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-6512-9_25

Download citation

  • DOI: https://doi.org/10.1007/978-1-4684-6512-9_25

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4684-6514-3

  • Online ISBN: 978-1-4684-6512-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics