Abstract
Enzyme imnunoassays (EIAs) are now known to be a viable alter-native to the more established radioimmunoassay techniques. The inproved sensitivity along with the inherently better speed, stability, and cost have resulted in the commercial production of several EIA systems (Monroe, 1984). Most systems have colorimet-rically monitored the indicating enzyme reaction. With the appropriate considerations, a fluorescence monitor can further enhance the sensitivity and selectivity of such methods without introducing significant sacrifices in the ease, speed, or cost of analysis (Kelly and Christian, 1982).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Brandt, R. and Keston, A.S. (1965). Synthesis of Diacetyldichloro-fluorescin: A Stable Reagent for Fluorimetric Analysis. Anal. Biochem. 11: 6–9.
Brown, S.S., Mitchell, F.L. and Young, D.S., Eds. (1979). Chemical Diagnosis of Disease. Elsevier/North-Holland Biomedical Press, Amsterdam.
Buffone, G.F., Savory, J. and Hermans, J. (1975). Evaluation of Kinetic Light Scattering as an Approach to the Measurement of Specific Proteins with the Centrifugal Analyzer. II. Theoretical Considerations. Clin. Chem. 21: 1735–1746.
Burd, J.F., Carrico, R.J., Fetter, M.C., Buckler, R.T., Johnson, R.D., Boguslaski, R.C. and Christner, J.E. (1977). Specific Protein-Binding Reactions Monitored by Enzymatic Hydrolysis of Ligand-Fluorescent Dye Conjugates. Anal. Biochem. 77: 56–67.
Burd, J.F., Carrico, R.J., Kramer, H.M. and Denning, C.E. (1978). Homogeneous Substrate-Labeled Fluorescence Immunoassay for Determining Tobramycin Concentrations in Human Serum. In Enzyme Labeled Immunoassay of Hormone and Drugs. Walter de Gruyter & Co., Berlin, 387–403.
Burd, J.F., Wong, R.C., Feeney, J.E., Carrico, R.J. and Boguslaski R.C. (1977). Homogeneous Reactant-Labeled Fluorescence Immunoassay for Therapeutic Drugs Exemplified by Gentamicin Determination in Human Serum. Clin, Chem. 23: 1402–1408.
Kelly, T.A. (1981). Fluorimetric, Electrochemical, and Flow In jection Analysis of Enzyme and Immunochemical Systems. Doctoral Dissertation.
Kelly, T.A. and Christian, G.D. (1981). Fluorimeter for Flow Injection Analysis with Aplication to Oxidase Enzyme-Dependent Reactions. Anal. Chem. 53: 2110–2114.
Kelly, T.A. and Christian, G.D. (1982). Capillary Flow Injection Analysis for Enzyme Assay with Fluorimetric Detection. Anal. Chem. 54: 1444–1445.
Kelly, T.A. and Christian, G.D. (1982). Homogeneous Enzymatic Fluorescence Immunoassay of Serum IgG by Continuous Flow Injection Analysis. Talanta 29: 1109–1112.
Litman, D.J., Hanlon, T.M. and Ullman, E.F. (1980). Enzyme Channeling Immunoassay: A New Homogeneous Enzyme Immunoassay Technique. Anal. Biochem. 106: 223–229.
Monroe, D. (1984). Enzyme Immunoassay. Anal. Chem. 56: 921A–931A.
Ngo, T.T., Carrico, R.J. and Boguslaski, R.C. (1979). Homogeneous Fluorescence Immunoassay for Protein using β-Galactosyl-Umbelliferone Label, paper presented at 2nd International Conference on Diagnostic Immunology, New England College, Henniker, New Hampshire.
Ngo, T.T., Carrico, R.J., Boguslaski, R.C., and Burd, J.P. (1981). Homogeneous Substrate-Labeled Fluorescence Immunoassay for IgG in Human Serum. J. Immunol. Methods 42: 93–103.
Ngo, T.T. and Lenhoff, H.M. (1981). Recent Advances in Homogeneous and Separation-Free Enzyme Immunoassays. Applied Biochem. & Biotechnol. 6: 53–64.
Ruzicka, J. and Hansen, E.H. (1981). Flow Injection Analysis. Wiley-Interscience, New York.
Soini, E. and Hemmila, I. (1979). Fluoroimmunoassay: Present Status and Key Problems. Clin. Chem. 25: 353–361.
Terumo Corp. Jpn. Kokai Tokkyo Koho. (September 7, 1983). Japan Patent No. 58,150,861. Immunoassay for the Determination of Drugs.
Wong, R.C., Burd, J.F., Carrico, R.J., Buckler, R.T., Thoma, J. and Boguslaski, R.C. (1979). Substrate-Labeled Fluorescence Immunoassay for Phenytoin in Human Serum. Clin. Chem. 25: 686–691.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1985 Plenum Press, New York
About this chapter
Cite this chapter
Kelly, T.A. (1985). Separation-Free Enzyme Fluorescence Immunoassay by Continuous Flow Injection Analysis. In: Ngo, T.T., Lenhoff, H.M. (eds) Enzyme-Mediated Immunoassay. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-5012-5_11
Download citation
DOI: https://doi.org/10.1007/978-1-4684-5012-5_11
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4684-5014-9
Online ISBN: 978-1-4684-5012-5
eBook Packages: Springer Book Archive