Abstract
A method for the recording of mass transport velocity in tissue, related to the relative local mass flow, has been developed. It is based on the heat clearance principle, applied in the continuous mode. Thermistors are used as temperature sensors; heating is performed by a high frequency square wave, thus avoiding an additional heating coil. The cooling of the heated thermistor, with as a reference a non-heated one, is related to the local mass transport velocity. A test equipment has been built for the calibration of the device and a set of results have been obtained in test fluids with a thermal conductivity approaching the one of brain tissue (glycerin and water). A mathematical model has been set up which gave results consistent with the recorded data. From this model significant parameters could be derived which, introduced in a compensation circuit, may be used in order to linearize the relation between the measuring value and the velocity variable. In vivo results in the brain cortex of the rabbit have been obtained.
Keywords
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Capon, A., 1971, Etude des variations rapides du débit sanguin cérébral local chez le lapin et chez le chat, mesurées par une méthode thermique, Les Publications “Acta Medica Belgica”, Bruxelles: 1–127
Coremans, J., Manil, J., Colin, F., Vermariën, H. and Bourgain, R., 1983, Relationship between spontaneous oscillations in cerebral cortical tissue oxygen pressure and microflow, Proc. Int. Symposium on cerebral ischemia, Toulouse 1983, France, to be published.
Fowlis, W. W., 1970, Techniques and apparatus for the fast and accurate measurement of fluid temperature and flow speed fields, Rev. Sci. Instrum., 41: 570–576
Junqueira, L. C., and Carneiro, J., 1981, Basic Histology, Lange Medical Publications, Los Altos
Müller-Schauenburg, W., Apfel, H., Benzing, H., and Betz, E., 1975, Quantitative measurement of local blood flow with heat clearance, Basic Res. Cardiol., 70: 547–567
Rasmussen, R., 1962, Application of thermistors to measurements in moving fluids, Rev. Sci. Instrum., 33: 38–42
Seylaz, J., 1965, Développement d’une méthode de mesure instantanee localisée et semi-quantitative du débit sanguin in vivo, Biophysik, 2: 330–339
Seylaz, J., Pinard, E., Dittmar, A., and Birer, A., 1979, Measurement of blood flow, tissue PO2, and tissue PCO2 continuously and simultaneously in the same structure of the brain, Med. & Biol. Eng. & Comp., 17: 19–24
Siesjö, B. K., 1978, Brain energy metabolism, J Wiley and Sons, New York
Weast, R. (ed.), 1971, Handbook of chemistry and physics, 51st edition 1970–1971, the Chemical Rubber Company
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1984 Plenum Press, New York
About this chapter
Cite this chapter
Vermariën, H., Coremans, J., Vereecke, F., Bourgain, R. (1984). A Thermistor Device for the Continuous Recording of Mass Transport Velocity in Tissue Based on the Heat Clearance Principle. In: Bruley, D., Bicher, H.I., Reneau, D. (eds) Oxygen Transport to Tissue—VI. Advances in Experimental Medicine and Biology, vol 180. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-4895-5_73
Download citation
DOI: https://doi.org/10.1007/978-1-4684-4895-5_73
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4684-4897-9
Online ISBN: 978-1-4684-4895-5
eBook Packages: Springer Book Archive