Abstract
Receiver beam-forming in ultrasonic phased array systems typically demands very wide-band delay systems, having wide dynamic range and often complicated electronics. Sampled approaches to these delay lines generally employ sampling rates at least twice the highest frequency component in the returned RF signal. However, since the RF is bandlimited about some center frequency, by sampling in quadrature with respect to this center frequency the actual sampling rate may be substantially lowered. This produces two channels of information — the in-phase or “real” component, and the quadrature or “imaginary” component. This “complex video” from each array element may be delayed and added to that from the other elements to provide receiver focusing. In addition to lowering the sampling rate, this technique retains all phase information for Doppler processing as well.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
J. C. Somer: Electronic sector scanning for ultrasonic diagnosis. Ultrasonics 6:153–159, 1968.
F. L. Thurstone and O. T. Von Ramm: A new ultrasound imaging technique employing two dimensional electronic beam steering. Acoustical Holography. Vol. 5, 1973.
H. E. Melton, Jr.: Electronic Focal Scanning for Improved Resolution in Ultrasound Imaging. Ph.D. thesis, Department of Biomedical Engineering, Duke University, 1971.
P. Doornbos and J. C. Somer: An electrically variable analogue delay achieved by fast consecutively commutated capacitors. Progress Report 3, Inst. Med. Phys. TNO, Da Costakade 45, Utrecht, The Netherlands, 1972.
R. E. McKeighen and M. P. Buchin: Evaluation of novel dynamically variable electronic delay lines for ultrasonic imaging. Ultrasonics in Med., Vol. 4, 1977.
R. E. McKeighen and M. P. Buchin: New techniques for dynamically variable electronic delays for real time ultrasonic imaging. Proceedings IEEE Ultrasonics Symposium, 1977.
J. T. Walker and J. D. Meindl: A digitally controlled CCD dynamically focused phased array. Proceedings IEEE Ultrasonics Symposium, 1975.
C. B. Burckhardt, P. A. Grandchamp, H. Hoffman, and R. Fehr: A Simplified Ultrasound Phased Array Sector Scanner. Echocardiology, C. T. Lancee, ed., pp. 385–393, 1979.
D. W. Baker: Pulsed Doppler Blood Flow Sensing. IEEE Trans. Sonics and Ultrasonics, SU-17, pp. 170–185, 1970.
M. A. Brandestini: Topoflow — A Digital Full Range Doppler Velocity Meter. IEEE Trans. Sonics and Ultrasonics, SU-25, pp. 287–293, 1978.
E. A. Howard, M. A. Brandestini, J. E. Powers, M. K. Eyer, D. J. Phillips, E. B. Weiler: Combined Two-Dimensional Tissue/Flow Imaging. Acoustical Imaging, this volume.
J. E. Powers, D. J. Phillips, M. A. Brandestini, R. A. Sigelmann: Ultrasound Phased Array Delay Lines Based on Quadrature Sampling Techniques. Submitted to IEEE Trans. Sonics Ultrasonics, Nov. 1979.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1980 Plenum Press, New York
About this chapter
Cite this chapter
Powers, J.E., Phillips, D.J., Brandestini, M., Ferraro, R., Baker, D.W. (1980). Quadrature Sampling for Phased Array Application. In: Wang, K.Y. (eds) Acoustical Imaging. Acoustical Imaging, vol 9. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-3755-3_18
Download citation
DOI: https://doi.org/10.1007/978-1-4684-3755-3_18
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4684-3757-7
Online ISBN: 978-1-4684-3755-3
eBook Packages: Springer Book Archive