Skip to main content

Problems Involved in the Measurement of Microcirculation by Means of Microelectrodes

  • Chapter
Oxygen Transport to Tissue

Part of the book series: Advances in Experimental Medicine and Biology ((AEMB,volume 37 A))

  • 120 Accesses

Abstract

Until now, the interpretation of local wash-out curves, measured by means of microelectrodes and using hydrogen as diffusible indicator, is an unsettled problem. It has been shown, that even the simultaneous measurement by means of a surface-multiwire-Pt-microelectrode at the isolated and hemoglobin-free perfused rat liver yields different wash-out curves (4). These differences occur with regard to the height of the curves as well as to the moment, when the maximum of the indicator’s concentration is seen by the microelectrode. Fig.1 represents four simultaneously recorded curves. The difference in sensitivity of each micro-electrode has been compensated by a computer. The fast curve corresponds the real input function to the liver and is directly measured in the inflow by means of a non-compensated electrode. Usually the evaluation of local hydrogen wash-out curves is performed in the same way as the evaluation of those clearance curves, which are measured by a large-scale detector, using 85-Krypton or 133-Xenon as indicator. The most commonly used methods are the slope-method (2) and the heightover-area-method (5). Application of these methods to local hydrogen wash-out curves yields different values for the local perfusion rate. Fig.2 shows the comparison between the mean perfusion rates, determined by means of the total inflow, and the local perfusion rates. In fig.2A the local perfusion rates were calculated using the height-over-area-method, whereas in fig.2B the slope-method was applied to the same curves.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 39.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Hutten,H.: Abh. Akad. Wiss. Lit. Mainz, Nr. 4 (1970).

    Google Scholar 

  2. Ingvar,D.H. and N.A.Lassen: Acta physiol. scand. 54, 325 (1962).

    Article  Google Scholar 

  3. Krogh,A.: Anatomie und Physiologie der Kapillaren. Springer-Verlag, Berlin (1924).

    Google Scholar 

  4. Thermann,M. and M.Kessler: In: Oxygen supply. Urban und Schwarzenberg, München und Berlin, University Park Press, Baltimore, 117 (1972).

    Google Scholar 

  5. Zierler,K.: Circulat. Res. XVI, 309 (1965).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1973 Springer Science+Business Media New York

About this chapter

Cite this chapter

Hutten, H., Kessler, M., Thermann, M. (1973). Problems Involved in the Measurement of Microcirculation by Means of Microelectrodes. In: Bicher, H.I., Bruley, D.F. (eds) Oxygen Transport to Tissue. Advances in Experimental Medicine and Biology, vol 37 A. Springer, Boston, MA. https://doi.org/10.1007/978-1-4684-3288-6_19

Download citation

  • DOI: https://doi.org/10.1007/978-1-4684-3288-6_19

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4684-3290-9

  • Online ISBN: 978-1-4684-3288-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics