Skip to main content

Constrained Deconvolution to Remove Resolution Degradation Caused by Scatter in Spect

  • Chapter
Information Processing in Medical Imaging

Abstract

Although one of the ultimate aims of SPECT is to provide quantitative information concerning the radionuclide distribution in the object being scanned, it is essential to realize that much of the diagnostic information in Nuclear Medicine imaging is gained from visual examination of the image (Muehllehner, 1985). An important goal in image enhancement or restoration is therefore to improve the accuracy and confidence of visual detection of small structures.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Andrews, H.C., and Hunt, B.R.,(1977). Digital Image Restoration, Prentice-Hall, Englewood Cliffs, NJ.

    Google Scholar 

  • Axelsson, B., Maki, P., and Israelsson, A.,(1984). Subtraction of Compton-scattered photons in single photon emission computerized tomography, J Nucl Med., 25, 490–494.

    Google Scholar 

  • Beck, R.N., Schuh M.W., Cohen, T.D., and Lernbares, N.,(1969). Effects of scattered radiation on scintillation detector response, in: Medical Radioisotope Scintigraphy, IAEA, Vienna, (1969).

    Google Scholar 

  • Beck, R.N., Jaszczak, R.J., Coleman, R.E., Starmer, C.F. and Loren, W.N.,(1982). Analysis of SPECT including scatter and attenuation using sophisticated Monte Carlo modelling methods, IEEE Trans Nucl. Sci, NS-29, 506–511.

    Google Scholar 

  • Egbert, S.D., and May, R.S. (1980). An integral-transport method for Compton-scatter correction in emission computed tomography, IEEE Trans Nucl Sci., NS-27, 543–549.

    Google Scholar 

  • Ehrhardt, J.C., Oberley, L.W., and Lensink, S.C.,(1974). Effect of a scattering medium on X-ray imaging, J Nucl Med., 15, 943–948.

    Google Scholar 

  • Gonzalez, R.C., and Wintz, P.,(1977). Digital Image Processing, Addison-Wesley Publishing Company, Reading, Massachusetts.

    Google Scholar 

  • Jaszczak, R.J., Coleman, R.E., and Whitehead, F.R.,(1981). Physical Factors affecting quantitative measurements using camera-based single-photon computed tomography (SPECT), IEEE Trans Nucl Sci., NS-28, 69–80.

    Google Scholar 

  • Jaszczak, R.J., Greer, K.L., Floyd, C.E., Harris, C.C., and Coleman, R.E.,(1984). Improved SPECT quantification using compensation for scattered photons, J Nucl Med., 25, 893–900.

    Google Scholar 

  • King, M.A., Doherty, P.W., and Schwinger, R.B.,(1983). A Wiener filter for nuclear medicine images, Med Phys., 10, 876–880.

    Article  Google Scholar 

  • King, M.A., Schwinger, R.B., and Penny, B.C.,(1986). Variation of the count-dependent Metz filter with imaging system modulation transfer function, Med Phys., 13, 139–149.

    Article  Google Scholar 

  • Lowry, C.A., and Taylor, D.N.,(1986). Improvements in image contrast and quantification using scatter subtraction in SPECT, Br J Radiol., 59, 728.

    Google Scholar 

  • Metz, C.E., Atkins, F.B., and Beck, R.N.,(1980). The geometric transfer function component for scintillation camera collimators with straight parallel holes, Phys Med Biol., 25, 1059–1070.

    Article  Google Scholar 

  • Miller, T.R., and Sampathkumaran, K.S.,(1982). Design and application of finite impulse response digital filters, Eur J Nucl Med., 7, 22–27.

    Article  Google Scholar 

  • Miracle, S., Yzuel, M.J., and Milan, S.,(1979). A study of the point spread function in scintillation camera collimators based on Fourier analysis, Phys Med Biol., 24, 372–384.

    Article  Google Scholar 

  • Muehllehner, G,(1985). Effect of resolution improvement on required count density in ECT imaging: a computer simulation, Phys Med Biol., 30, 163–173.

    Article  Google Scholar 

  • Pang, S.C., and Genna, S.,(1979). The effect of Compton scattered photons on emission computerized transaxial tomography, IEEE Trans Nucl Sci NS-26, 2772–2774.

    Google Scholar 

  • Todd-Pokropek, A.,(1980). Image Processing in Nuclear Medicine, IEEE Trans Nucl Sci., NS-27, 1080–1094.

    Google Scholar 

  • Tsui, B.M.W., Gunter, D.L., and Beck, R.N.,(1982). Study of spatial resolution in single photon ECT, J Nucl Med., 23, p45.

    Google Scholar 

  • Waggett, D.J., and Wilson, B.C.,(1977). Improvement of scanner performance by subtraction of Compton scattering using multiple energy windows, Br J Radiol., 51, 1004–1010.

    Article  Google Scholar 

  • Webb, S., Long, A.P., Ott, R.J., Leach, M.O., and Flower, M.A.,(1985). Constrained deconvolution of SPECT liver tomograms by direct digital image restoration, Med Phys., 12, 53–58.

    Article  Google Scholar 

  • Ying-Lee, O.,(1983). An ECAT reconstruction method which corrects for attenuation and detector response, IEEE Trans Nucl Sci., NS-30, 632–635.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1988 Springer Science+Business Media New York

About this chapter

Cite this chapter

Yanch, J.C., Webb, S., Flower, M.A., Irvine, A.T. (1988). Constrained Deconvolution to Remove Resolution Degradation Caused by Scatter in Spect. In: de Graaf, C.N., Viergever, M.A. (eds) Information Processing in Medical Imaging. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-7263-3_17

Download citation

  • DOI: https://doi.org/10.1007/978-1-4615-7263-3_17

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4615-7265-7

  • Online ISBN: 978-1-4615-7263-3

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics