Skip to main content

Abstract

The importance of understanding mechanisms of blood-material interactions is emphasized by the increasingly widespread use of cardiovascular devices; hence, this field has been the subject of intense inquiry as described in several excellent reviews [1–4]. Unfortunately, it is still not possible to simply rank or classify materials with respect to their suitability for particular blood-contacting applications. Nor is it possible to predict in any general way, based on the properties of devices and of their blood-contacting surfaces, the behavior of blood in contact with materials or the propensity of devices to produce clinically adverse events. Despite many attempts to correlate biologic responses to physicochemical property measurements, our success in understanding blood-material interactions, and the clinical application of many blood-contacting devices, has been largely empirical. It is not appropriate to discuss in detail this large and controversial literature, which has been reviewed elsewhere [1, 2]. Rather, this section will focus on the available experimental data in humans, or results which may likely be extrapolated to humans from relevant animal studies, that may guide in the development of new designs for blood-contacting devices. Cardiovascular device applications in humans have also been the subject of an excellent review [5].

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Salzman, E.W., Merrill, E.W. and Kent K.C. (1994) Interaction of blood with artificial surfaces, in Hemostasis and Thrombosis: Basic Principles and Clinical Practice, 3rd edn, R.W. Colman, J. Hirsch, V.J. Marder, and Salzman, E.W. (eds), J.B. Lippincott, Philadelphia, pp. 1469–85.

    Google Scholar 

  2. Harker, L.A., Ratner, B.D. and Didisheim, P. (eds) (1993) Cardiovascular Biomaterials and Biocompatibility, Cardiovascular Pathology 2(3)(supplement), 1S-224S.

    Google Scholar 

  3. Szycher, M. (ed.) (1983) Biocompatible Polymers, Metals, and Composites, Technomic Publishing Co., Lancaster, Pennsylvania.

    Google Scholar 

  4. Williams, D.F. (ed) (1981) Biocompatibility of Clinical Implant Materials, CRC Press, Boca Raton, Florida.

    Google Scholar 

  5. Clagett, G.P. and Eberhart, R.C. (1994) Artificial Devices in Clinical Practice, in Hemostasis and Thrombosis: Basic Principles and Clinical Practice, 3rd edn R.W. Colman, J. Hirsch, V.J. Marder, and Salzman, E.W. (eds), J.B. Lippincott, Philadelphia, pp. 1486–1505.

    Google Scholar 

  6. Grabowski, E.F., Didisheim, P., Lewis, J.C. et al. (1977) Platelet adhesion to foreign surfaces under controlled conditions of whole blood flow: human vs. rabbit, dog, calf, sheep, pig, macaque, and baboon. Transactions — American Society for Artificial Internal Organs, 23, 141–51.

    Article  PubMed  CAS  Google Scholar 

  7. Lentner, C. (ed.) (1984) Geigy Scientific Tables (vol. 3): Physical Chemistry, Composition of Blood, Hematology, Somatometric Data, Ciby-Geigy, Basle.

    Google Scholar 

  8. Brash, J.L. and Horbett, T.A. (eds) (1987) Proteins at Interfaces. Physicochemical and Biochemical Studies, American Chemical Society, Washington, DC.

    Google Scholar 

  9. Harker, L.A. and Slichter, S.J. (1972) Platelet and fibrinogen consumption in man. New England J Med. 287(20), 999–1005.

    Article  CAS  Google Scholar 

  10. Bennett, B., Booth, N.A., Ogston D. (1987) Potential interactions between complement, coagulation, fibrinolysis, kinin-forming, and other enzyme systems, in: Haemostasis and Thrombosis (2nd edn), A.L. Bloom and D.P. Thomas (eds), Churchill Livingstone, New York, pp. 267–82.

    Google Scholar 

  11. Andrew, M. (1995) Developmental hemostasis: relevance to thromboembolic complications in pediatric patients. Thrombosis and Hemostasis, 74(1), 415–25.

    CAS  Google Scholar 

  12. Hanson, S.R., Harker, L.S., Ratner, B.D. et al. (1980) In vivo evaluation of artificial surfaces using a nonhuman primate model of arterial thrombosis. J Laboratory Clinical Med. 95, 289–304.

    CAS  Google Scholar 

  13. Silver, J.H., Myers, C.W., Lim, F. et al. (1994) Effect of polyol molecular weight on the physical properties and haemocompatibility of polyurethanes containing polyethylene oxide macroglycols. Biomaterials 15(9), 695–704.

    Article  PubMed  CAS  Google Scholar 

  14. Hoffman, A.S. (1974) Principles governing biomolecular interactions at foreign surfaces. J. Biomedical Materials Res. (Symp.) 5(1), 77–83.

    Article  Google Scholar 

  15. Andrade, J.D., Lee, H.B., Jhon, M.S. et al. (1973) Water as a biomaterial. Transactions — American Society for Artificial Internal Organs 19, 1–7.

    Article  PubMed  CAS  Google Scholar 

  16. Strzinar, I. and Sefton, M.V. (1992) Preparation and thrombogenicity of alkylated polyvinyl alcohol coated tubing. J. Biomedical Materials Research 26, 577–92.

    Article  CAS  Google Scholar 

  17. Merrill, E.W. (1993) Poly(ethylene oxide) star molecules: synthesis, characterization, and applications in medicine and biology. J. Biomaterials Science, Polymer Edition 5(1-2), 1–11.

    Article  CAS  Google Scholar 

  18. Llanos, G.R. and Sefton, M.V. (1993) Does polyethylene oxide possess a low thrombogenicity? J. Biomaterials Science, Polymer Edition, 4(4), 381–400.

    Article  CAS  Google Scholar 

  19. Sigwart, U., Puel, J., Mirkovitch, V. et al. (1987) Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty. New England J. Med, 316(12), 701–6.

    Article  CAS  Google Scholar 

  20. Scott, N.A., Nunes, G.L., King, S.B. et al. (1995) A comparison of the thrombogenicity of stainless steel and tantalum coronary stents. American Heart J., 129, 866–72.

    Article  CAS  Google Scholar 

  21. Saywer, P.N., Stanczewski, B., Lucas, T.R., et al. (1978) Physical chemistry of the vascular interface, in Vascular Grafts, P.N. Sawyer and M.J. Kaplitt (eds), Appleton-Century-Crofts, New York, pp. 53–75.

    Google Scholar 

  22. Rapold, HJ., Stassen, T., Van de Werf, F., et al. (1992) Comparative copper coil-induced thrombogenicity of the internal mammary, left anterior descending coronary, and popliteal arteries in dogs. Arteriosclerosis and Thrombosis, 12(5), 634–44.

    Article  Google Scholar 

  23. Schoen, F.J. (1983) Carbons in heart valve prostheses: Foundations and clinical performance, in M. Szycher (ed.), Biocompatible Polymers, Metals, and Composites, Technomic Publishing Co., Lancaster, Pennsylvania, pp. 239–61.

    Google Scholar 

  24. Yasuda, H.K. (1985) Plasma Polymerization, Academic Press, Orlando.

    Google Scholar 

  25. Yeh, Y.S., Iriyama, T., Matsuzawa, Y., et al. (1988) Blood compatibility of surfaces modified by plasma polymerization. J. Biomedical Materials Research, 22, 795–818.

    Article  CAS  Google Scholar 

  26. Harker, L.A., Malpass, T.W., Branson H.E., et al. (1980) Mechanism of abnormal bleeding in patients undergoing cardiopulmonary bypass: acquired transient platelet dysfunction associated with selective alpha-granule release. Blood, 56(5), 824–34.

    PubMed  CAS  Google Scholar 

  27. Hakim, R. (1993) Complement activation by biomaterials. Cardiovascular Pathology, 2(3)(suppl), 187–198.

    Article  Google Scholar 

  28. Yu, J., Lamba, N.M., Courtney J.M., et al. (1994) Polymeric biomaterials: Influence of phosphorylcholine polar groups on protein adsorption and complement activation. International Journal of Artificial Organs, 17(9), 499–504.

    PubMed  CAS  Google Scholar 

  29. Hardhammer, P.A., van Beusekom H.M., Emanuelsson, H.U., et al. (1996) Reduction in thrombotic events with heparin-coated Palmaz-Schatz stents in normal porcine coronary arteries. Circulation, 93(3), 423–30.

    Article  Google Scholar 

  30. Schneider, P.A., Kotze, H.F., Heyns, A. duP., et al. (1989) Thromboembolic potential of synthetic vascular grafts in baboons. J. Vascular Surgery, 10, 75–82.

    CAS  Google Scholar 

  31. Dasse, K.A., Poirier, V.L., Menconi, M.J., et al. (1990) Characterization of TCPS textured blood-contacting materials following long-term clinical LVAD support. In: Cardiovascular Science and Technology: Basic and Applied: II, JC Norman (ed.), Oxymoron Press, Boston, MA, pp. 218–220.

    Google Scholar 

  32. Kormos, R.L., Armitage, J.M., Borovetz, H.S., et al. (1990) Univentricular support with the Novocor left ventricular assist system as a bridge to cardiac transplantation: An update in Cardiovascular Science and Technology: Basic and Applied: II, JC Norman (Ed), Oxymoron Press, Boston, MA, pp. 322–324.

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1998 Springer Science+Business Media Dordrecht

About this chapter

Cite this chapter

Hanson, S.R. (1998). Blood-material interactions. In: Black, J., Hastings, G. (eds) Handbook of Biomaterial Properties. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-5801-9_32

Download citation

  • DOI: https://doi.org/10.1007/978-1-4615-5801-9_32

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-0-412-60330-3

  • Online ISBN: 978-1-4615-5801-9

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics