Abstract

In Chapters 7–10 various schemes which are used to protect overload lines and cables have been considered. All of these schemes are of the unit type in that they should operate whenever faults above certain levels of current occur on the protected units, i.e. between the current transformers mounted at each of the ends of the units, and they should not operate when external faults are present or during any healthy conditions. In each case this desired performance is obtained by making use of information about the conditions at both ends of a protected unit at any time. As examples, the instantaneous input and output currents of lines are compared in current-comparison (Merz-Price) schemes, the phases of currents are compared in ‘phase-comparison’ schemes and the directions of currents are taken into account in interlock schemes. To effect the necessary comparisons, signals must be sent between the ends of protected units which may, of course, be quite long distances apart, and either pilot wires or optical fibres or other high frequency electronic communication equipment may be required for this purpose.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Ackerman, P. (1922) Journal of the Engineering Institute of Canada, Dec. 1922 (also New radial relay protection, Electrical World, 81, March 17, 1923, pp. 619–623 ).

    Google Scholar 

  2. Crichton, L. N. (1923) The distance relay for automatically sectionalising electrical networks, Trans. IEE, XLII, 527–537.

    Google Scholar 

  3. McLaughlin, H. A. and Erickson, E. O. (1928) The impedance relay development and application, Trans. IEE, July 1928, 47, 776–784.

    Google Scholar 

  4. George, E. E. (1931) Operating experience with reactance type distance relays, Trans. IEE, 50, 288–293.

    Google Scholar 

  5. Ellis, N. S. (1982): Distance protection of feeders. In Power System Protection Manual, Reyrolle Protection, (ed D. Robertson ), Oriel Press, pp. 149–179.

    Google Scholar 

  6. Wright, A. (1961) Limitations of distance-type protective equipment when applied to long extremely high voltage power lines, Proc IEE, (C), 108, 271–280.

    Google Scholar 

  7. Davison, E. B. and Wright, A. (1963) Some factors affecting the accuracy of distance-type protective equipment under earth fault conditions, Proc IEE, 110, 1678–1688.

    Google Scholar 

  8. Micromho-Static distance protection relay, GEC Measurements, Publication R5406.

    Google Scholar 

  9. Power Swing Blocking Relay, Type LU91, Asea Brown Boveri, (1987), Publication CH-ES-66.51.11.

    Google Scholar 

  10. Reyrolle Ratio Balance Distance Protection Type XZA Pamphlet 1044 (1951).

    Google Scholar 

  11. Type LFZP Optimho Static distance protection relay, GEC Measurements, Publication R-4056 C,18 pages.

    Google Scholar 

  12. High-speed distance protection relay 7SL32, Siemens Protective Relays, Catalog R-1989,pp 5/21–5/26.

    Google Scholar 

  13. Distance protection schemes, In Protective Relays Application Guide, GEC Measurements (3rd edn), 1987, Chapter 12.

    Google Scholar 

  14. Mathews, C. A. and Wilkinson, S. B. (1980) Series compensated line protection with a directional comparison relay scheme, 2nd IEE Int Conf. on Developments in Power System Protection, IEE Conf. Publ. No. 185, pp. 215–220.

    Google Scholar 

  15. El-Kaleb, M. M. and Cheetham, W. J. (1980) Problems in the protection of series compensated lines, 2nd IEE Int. Conf. on Development in Power System Protection, IEE Conf. Publ. No. 185.

    Google Scholar 

  16. Newbold, A. and Taylor, I. A. (1989) Series compensated line protection: system modelling and relay testing, 4th IEE Inn. Conf. on Developments in Power System Protection, IEE Conf. Publ. No. 302, pp. 182–186.

    Google Scholar 

  17. Mann, B. J. and Morrison, I. F. (1971) Digital calculation of impedance for transmission line protection, Trans. IEE, PAS-90, 270–279.

    Google Scholar 

  18. Girgis, A. A. and Brown, R. G. (1981) Application of Kalman filtering in computer relaying, Trans. IEE, PAS-100, 3387–3397.

    Google Scholar 

  19. McInnes, A.D.and Morrison, L.F.(1970) Real time calculation of resistance and reactance for transmission line protection by digital computer, Elec.Eng.Trans.,IE, Australia, EE7,(1),16–23.

    Google Scholar 

  20. Ranjibar, A. M. and Cory, B. J. (1975): Algorithms for distance protection, Developments in Power System Protection, IEE Conf. Publ. 125, London, March 1975, pp 276–283.

    Google Scholar 

  21. Sanderson, J. V. H. and Wright, A. (1974) Protection scheme for series-compensated transmission lines, Proc IEEE, 121, 1377–1384.

    Google Scholar 

  22. Microprocessor relays and protection systems, IEE Tutorial Course,(Course coordinator Ms Sachdev), 88EH0269–1-PWR.

    Google Scholar 

  23. Phadke, A. G. and Thorpe, J. S. (1988) Computer Relaying for Power Systems,RSP.

    Google Scholar 

  24. Holweck, C. (1990) Design and performance of PXLN digital protection devices for EHV/UHV power systems, GEC Alsthom Technical Review, No. 2, pp. 23–24.

    Google Scholar 

Further Reading

  • Analysis of distance protection, V. Cook, RSP 1986, 188 pages.

    Google Scholar 

  • Protection aspects of multi-terminal lines, IEE Power Eng. Soc. Publ,IEEE Report No 79, TH 0056–2-PWR, 1979, pp. 1–17.

    Google Scholar 

  • Determination of time settings in a distance protection scheme based on statistical methods, J. De Haas, CIGRE-report 31–05.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

Copyright information

© 1993 A. Wright and C. Christopoulos

About this chapter

Cite this chapter

Wright, A., Christopoulos, C. (1993). Distance-type protective schemes for overhead lines and cables. In: Electrical Power System Protection. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-3072-5_11

Download citation

  • DOI: https://doi.org/10.1007/978-1-4615-3072-5_11

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4613-6341-5

  • Online ISBN: 978-1-4615-3072-5

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics