Skip to main content

Thermal Characteristics of the Magcool Cryogenic System After Quenches of Rhic Dipoles

  • Chapter
  • 20 Accesses

Part of the book series: Advances in Cryogenic Engineering ((ACRE,volume 39))

Abstract

Thermal characteristics of the MAGCOOL cryogenic system after both natural and heater-induced quenches of the RHIC dipoles have been investigated. For natural quench currents around 6700 amperes, the pressure in the cooling loop exceeded the 15 atmosphere (15.2 MPa) setting of the quench relief valve causing helium to vent through the valve. The initial pressure rise rate was approximately 18 atm/min and the loop pressure increased from 5 to 15 atm in about 30 seconds. To ensure that no helium was vented from the MAGCOOL cooling loop in order to minimize uncertainties in the thermal measurements and better understand the heating/cooling process, the RHIC magnet was then quenched at lower currents between 2000 and 5000 amperes using a strip heater on the magnet coils. A series of tests with the cooling loop connected to a large volume surge tank was also performed to show the dependence of loop pressure on the loop volume. The peak pressure and temperature in the magnet cooling loop were found to be linearly proportional to the energy released for a given loop volume. The time lag of temperature along the cooling loop during quench recovery was determined. Very good agreement between total cooling provided and the magnetic stored energy was found for each of the several values of quench current.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   259.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. K. C. Wu, Performance of the MAGCOOL-subcooler cryogenic system after 50 mm SSC dipole quenches, in “Supercollider 4”, p.483, Plenum Press, New York (1992)

    Chapter  Google Scholar 

  2. K. C. Wu, Peak loop pressure and temperature and comparison of total cooling provided to the energy released after low current quenches of SSC dipoles in MAGCOOL cryogenic system, presented in the CEC-ICMC conference, July 12–16, 1993, Albuquerque, N. M.

    Google Scholar 

  3. K. C. Wu, Performance of the MAGCOOL-subcooler cryogenic system after SSC quadrupole quenches, presented in the fifth International Industrial Symposium on the Super Collider, May 6–8, 1993, San Francisco, Ca.

    Google Scholar 

  4. J. A. Bamberger, M. Afrashteh, D.P. Brown, W. J. Schneider, J. H. Sondericker and K. C. Wu, “MAGCOOL”-The production cooling facility for ISABELLE magnets, in “Advances in Cryogenic Engineering”, 27: 533, Plenum Press, New York (1981)

    Google Scholar 

  5. K. C. Wu, D. P. Brown, J. H. Sondericker, Y. Farah, D. Zantopp and A. Nicolletti, Subcooler assembly for SSC single magnet test program, in “Advances in Cryogenic Engineering”, 37A: 763, Plenum Press, New York (1991)

    Google Scholar 

  6. K. C. Wu, Operating experience using venturi flow meters at liquid helium temperature, in “Advances in Instrumentation and Control”, Vol. 47, Part 1, p.479, Instrument Society of America, N. C. (1992)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1994 Springer Science+Business Media New York

About this chapter

Cite this chapter

Wu, K.C. (1994). Thermal Characteristics of the Magcool Cryogenic System After Quenches of Rhic Dipoles. In: Kittel, P. (eds) Advances in Cryogenic Engineering. Advances in Cryogenic Engineering, vol 39. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-2522-6_42

Download citation

  • DOI: https://doi.org/10.1007/978-1-4615-2522-6_42

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4613-6074-2

  • Online ISBN: 978-1-4615-2522-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics