Abstract
A fluorescence-based immunosensor has been developed for simultaneous analysis of multiple samples. A patterned array of recognition elements immobilized on the surface of a planar waveguide is used to capture analyte present in samples; bound analyte is then quantified by means of fluorescent detector molecules. Upon excitation of the fluorescent label by a small diode laser, a CCD camera detects the pattern of fluorescent antigen:antibody complexes on the sensor surface. Image analysis software correlates the position of fluorescent signals with the identity of the analyte. This immunosensor was used to detect physiologically relevant concentrations of staphylococcal enterotoxin B (SEB), F1 antigen from Yersinia pestis, and Ddimer, a marker of sepsis and thrombotic disorders, in spiked clinical samples. Analysis of blind samples also demonstrated the capability of the sensor to analyze for bacteria, viruses, and proteins in simultaneous assays.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Ekins, R.; Chu, R. Clin. Chem. 1993, 39, 369–370.
Berger, C.E.H., Beumer, T.A.M., Kooyman, R.P.H.; Greve, J. Anal. Chem. 1998, 70, 703–706.
Frebel, H.; Chemnitius, G.-C.; Cammann, K.; Kakerow, R.; Rospert, M.; Mokwa, W. Sens. Actuators B, 1997, 43, 87–93.
Silzel, J. W.; Cercek, B.; Dodson, C.; Tsay, T.; Obremski, R.J. Clin. Chem. 1998, 44, 2036–2043.
Pritchard, D.J.; Morgan, H.; Cooper, J.M.; Anal. Chim. Acta 1995, 310, 251–256.
Rowe, C. A.; Scruggs, S. B.; Feldstein, M. J.; Golden, J. P.; Ligler, F. S. Anal Chem. 1999, 71, 433–439.
Rowe, C.A.; Tender, L.M.; Feldstein, M.J.; Golden, J.P.; Scruggs, S.B.; MacCraith, B.; Cras, J.; Ligler, F.S. Anal. Chem. 1999, 71, 3846–3852.
Plowman, T.E., Durstchi, J.D., Wang, H.K.; Christensen, D.A.; Herron, J.N.; Reichert, W.M. Anal.Chem. 1999, 71, in press.
Wadkins, R. M.; Golden, J. P.; Ligler, F. S. J. Biomed. Optics 1997, 2, 74–79.
Feldstein, M. J., Golden, J. P.; Rowe, C. A.; MacCraith, B. D.; Ligler, F. S. J. Biomed. Microdevices, 1999, 1, 139–153.
Cras, J.; Rowe, C.A.; Nivens, D.; Ligler, F.S. Biosensors & Bioelecíronics, 1999, in press.
Bhatia, S. K.; Shriver-Lake, L. C.; Prior, K. J., Georger, J. H.; Calvert, J. M.; Bredehorst, R.; Ligler, F. S. Anal. Bioc1hem. 1989, 178, 408–413.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2000 Springer Science+Business Media New York
About this chapter
Cite this chapter
Ligler, F.S., Hazzard, J.W., Golden, J.P., Rowe, C.A. (2000). Array Biosensor for Simultaneous Detection of Multiple Analytes. In: Liron, Z., Bromberg, A., Fisher, M. (eds) Novel Approaches in Biosensors and Rapid Diagnostic Assays. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-1231-8_2
Download citation
DOI: https://doi.org/10.1007/978-1-4615-1231-8_2
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4613-5452-9
Online ISBN: 978-1-4615-1231-8
eBook Packages: Springer Book Archive