Abstract
Recently, SF6 has been identified as a greenhouse gas with a long atmospheric lifetime1. Therefore, recycling guidelines for SF6 in electrical power equipment have been discussed, and the reduction of the release of SF6 to the atmosphere has progressed2. In addition, many researchers have investigated alternative insulation gases to SF6 3-5. High-pressure N2 gas is one of the proposed alternative gases that have no need of SF6. Pure N2 has a lower withstand voltage level than SF6, but has the advantage of being not only environmentally friendly, but also low in cost and safe. The breakdown characteristics of compressed N2 have already been discussed as part of the basic study on gas discharge in the 1930s6. However, most data on the electrical breakdown of compressed N2 were obtained under limited experimental conditions (small electrode scale or kinds of applied voltage waveform), and are not sufficient to estimate the insulation performance.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Intergovernmental Panel on Climate Change (IPCC), “Radiative Forcing of Climate Change”, pl72, (1994).
CIGRE TF 01 of WG 23.10, “SF6 Recycling Guide, Re-use of SF6 Gas in Electric Power Equipment and Final Disposal”, Electra, No.173, pp.43–71, (1997).
T. Takuma, S. Hamada, 0. Yamamoto, “Application of a Gas Mixture with c-QF8 in Gas Insulation”, Proc. of 11th ISH, Vol.3, pp.197–200, London, (1999).
A. Diessner, M. Finkel, A Grund and E. Kynast, “Dielectric Properties of N2/SF6 Mixtures for Use in GIS or GIL” Proc. of 11 th ISH, Vol.3, pp.67–70, London, (1999).
X. Waymel, “Low SF6 Concentration SF6/N2 Mixture for GIL”, Gaseous Dielectrics VIII, pp.345–351, (1998).
A H. Howell, “Breakdown Studies in Compressed Gases”, Trans. AIEE, Vol.58, pp.193–206,1939.
H. Goshima, H. Shinkai and M.Yashima, “Lightning Impulse Breakdown Characteristics of High-pressure Nitrogen Gas under Quasi-Uniform Field Gap”, Proc. of 10th ACED, No.A-108, pp.67–70, Kyoto, (2000).
M.Yashima, T. Takuma and T. Kawamoto, “Basic Study on Hybrid-Gas-Insulated Transmission Line (H-GIL)”,Proc. of 9th ISH, No.7880, Graz, (1995).
M. Yashima, T. Kawamoto, H. Fujinami and T. Takuma, “A Study on Breakdown Characteristics of Hybrid Gas Insulated Transmission Line (H-GIL)”, Proc. of 10 th ISH, Vol.2, pp.5–8, Montreal, (1997).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2001 Springer Science+Business Media New York
About this chapter
Cite this chapter
Goshima, H., Shinkai, H., Yashima, M. (2001). Lightning Impulse Breakdown Characteristics of High-Pressure N2 as an Alternative Insulation Gas to SF6 . In: Christophorou, L.G., Olthoff, J.K. (eds) Gaseous Dielectrics IX. Springer, Boston, MA. https://doi.org/10.1007/978-1-4615-0583-9_50
Download citation
DOI: https://doi.org/10.1007/978-1-4615-0583-9_50
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4613-5143-6
Online ISBN: 978-1-4615-0583-9
eBook Packages: Springer Book Archive