Skip to main content

Cardiac MR in Patients with Implantable Arrhythmia Devices

  • Chapter
  • First Online:
  • 2559 Accesses

Abstract

Magnetic resonance imaging (MRI) has become an established method of cardiovascular imaging in many clinical situations. In recent years, newer MRI techniques have been developed allowing both morphology assessment and functional evaluation of patients with congenital heart disease (CHD) (Knauth Meadows et al., Semin Roentgenol 43:246–258, 2008; Marcotte et al., Congenit Heart Dis 4:216–230, 2009). Furthermore, it has been shown that MRI is superior to echocardiography for certain anatomic regions due to acoustic window limitations, particularly in the pulmonary artery branches and the aortic arch in adult patients. MRI is currently established as the gold standard for measurements of ventricular volumes as well as for blood flow analysis (Koskenvuo et al., Clin Physiol Funct Imaging 27:385–393, 2007; Maceira et al., Eur Heart J 27:2879–2888, 2006; Kilner et al., J Cardiovasc Magn Reson 9:723–728, 2007; Prakash et al., Am J Cardiol 93:657–661, 2004). These advantages coupled with the freedom from ionizing radiation make MRI an attractive noninvasive imaging tool for patients with CHD (Rebergen and de Roos Herz 25:365–383, 2000).

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   149.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   199.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   279.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. Knauth Meadows A, Ordovas K, Higgins CB, Reddy GP. Magnetic resonance imaging in the adult with congenital heart disease. Semin Roentgenol. 2008;43:246–58.

    Article  PubMed  Google Scholar 

  2. Marcotte F, Poirier N, Pressacco J, et al. Evaluation of adult congenital heart disease by cardiac magnetic resonance imaging. Congenit Heart Dis. 2009;4:216–30.

    Article  PubMed  Google Scholar 

  3. Koskenvuo JW, Karra H, Lehtinen J, et al. Cardiac MRI: accuracy of simultaneous measurement of left and right ventricular parameters using three different sequences. Clin Physiol Funct Imaging. 2007;27:385–93.

    Article  PubMed  Google Scholar 

  4. Maceira AM, Prasad SK, Khan M, Pennell DJ. Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. Eur Heart J. 2006;27:2879–88.

    Article  PubMed  Google Scholar 

  5. Kilner PJ, Gatehouse PD, Firmin DN. Flow measurement by magnetic resonance: a unique asset worth optimising. J Cardiovasc Magn Reson. 2007;9:723–8.

    Article  PubMed  Google Scholar 

  6. Prakash A, Powell AJ, Krishnamurthy R, Geva T. Magnetic resonance imaging evaluation of myocardial perfusion and viability in congenital and acquired pediatric heart disease. Am J Cardiol. 2004;93:657–61.

    Article  PubMed  Google Scholar 

  7. Rebergen SA, de Roos A. Congenital heart disease. Evaluation of anatomy and function by MRI. Herz. 2000;25:365–83.

    Article  PubMed  CAS  Google Scholar 

  8. Anderson RH, Becker AE, Arnold R, Wilkinson JL. The conducting tissues in congenitally corrected transposition. Circulation. 1974;50:911–23.

    Article  PubMed  CAS  Google Scholar 

  9. Huhta JC, Maloney JD, Ritter DG, Ilstrup DM, Feldt RH. Complete atrioventricular block in patients with atrioventricular discordance. Circulation. 1983;67:1374–7.

    Article  PubMed  CAS  Google Scholar 

  10. Connelly MS, Liu PP, Williams WG, Webb GD, Robertson P, McLaughlin PR. Congenitally corrected transposition of the great arteries in the adult: functional status and complications. J Am Coll Cardiol. 1996;27:1238–43.

    Article  PubMed  CAS  Google Scholar 

  11. Thiene G, Wenink AC, Frescura C, et al. Surgical anatomy and pathology of the conduction tissues in atrioventricular defects. J Thorac Cardiovasc Surg. 1981;82:928–37.

    PubMed  CAS  Google Scholar 

  12. Manning PB, Mayer Jr JE, Wernovsky G, Fishberger SB, Walsh EP. Staged operation to Fontan increases the incidence of sinoatrial node dysfunction. J Thorac Cardiovasc Surg. 1996;111:833–9; discussion 839–40.

    Article  PubMed  CAS  Google Scholar 

  13. Alexander ME, Cecchin F, Walsh EP, Triedman JK, Bevilacqua LM, Berul CI. Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics. J Cardiovasc Electrophysiol. 2004;15:72–6.

    Article  PubMed  Google Scholar 

  14. Alexander ME, Walsh EP, Saul JP, Epstein MR, Triedman JK. Value of programmed ventricular stimulation in patients with congenital heart disease. J Cardiovasc Electrophysiol. 1999;10:1033–44.

    Article  PubMed  CAS  Google Scholar 

  15. Dore A, Santagata P, Dubuc M, Mercier LA. Implantable cardioverter defibrillators in adults with congenital heart disease: a single center experience. Pacing Clin Electrophysiol. 2004;27:47–51.

    Article  PubMed  Google Scholar 

  16. Dubin AM. Resynchronization in pediatrics who needs it? J Am Coll Cardiol. 2005;46:2290–1.

    Article  PubMed  Google Scholar 

  17. Janousek J, Vojtovic P, Hucin B, et al. Resynchronization pacing is a useful adjunct to the management of acute heart failure after surgery for congenital heart defects. Am J Cardiol. 2001;88:145–52.

    Article  PubMed  CAS  Google Scholar 

  18. Zimmerman FJ, Starr JP, Koenig PR, Smith P, Hijazi ZM, Bacha EA. Acute hemodynamic benefit of multisite ventricular pacing after congenital heart surgery. Ann Thorac Surg. 2003;75:1775–80.

    Article  PubMed  Google Scholar 

  19. Bacha EA, Zimmerman FJ, Mor-Avi V, et al. Ventricular resynchronization by multisite pacing improves myocardial performance in the postoperative single-ventricle patient. Ann Thorac Surg. 2004;78:1678–83.

    Article  PubMed  Google Scholar 

  20. Janousek J, Gebauer RA. Cardiac resynchronization therapy in pediatric and congenital heart disease. Pacing Clin Electrophysiol. 2008;31 Suppl 1:S21–3.

    Article  PubMed  Google Scholar 

  21. Khairy P, Fournier A, Thibault B, Dubuc M, Therien J, Vobecky SJ. Cardiac resynchronization therapy in congenital heart disease. Int J Cardiol. 2006;109:160–8.

    Article  PubMed  Google Scholar 

  22. Strieper M, Karpawich P, Frias P, et al. Initial experience with cardiac resynchronization therapy for ventricular dysfunction in young patients with surgically operated congenital heart disease. Am J Cardiol. 2004;94:1352–4.

    Article  PubMed  Google Scholar 

  23. Janousek J, Gebauer RA, Abdul-Khaliq H, et al. Cardiac resynchronisation therapy in paediatric and congenital heart disease: differential effects in various anatomical and functional substrates. Heart. 2009;95:1165–71.

    Article  PubMed  CAS  Google Scholar 

  24. Nazarian S, Halperin HR. How to perform magnetic resonance imaging on patients with implantable cardiac arrhythmia devices. Heart Rhythm. 2009;6:138–43.

    Article  PubMed  Google Scholar 

  25. Tandri H, Zviman MM, Wedan SR, Lloyd T, Berger RD, Halperin H. Determinants of gradient field-induced current in a pacemaker lead system in a magnetic resonance imaging environment. Heart Rhythm. 2008;5:462–8.

    Article  PubMed  Google Scholar 

  26. Roguin A, Zviman MM, Meininger GR, et al. Modern pacemaker and implantable cardioverter/defibrillator systems can be magnetic resonance imaging safe: in vitro and in vivo assessment of safety and function at 1.5 T. Circulation. 2004;110:475–82.

    Article  PubMed  Google Scholar 

  27. Sommer T, Naehle CP, Yang A, et al. Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: a prospective study with 115 examinations. Circulation. 2006;114:1285–92.

    Article  PubMed  Google Scholar 

  28. Vahlhaus C. Heating of pacemaker leads during magnetic resonance imaging. Eur Heart J. 2005;26:1243; author reply 1243–4.

    Article  PubMed  Google Scholar 

  29. Nazarian S, Roguin A, Zviman MM, et al. Clinical utility and safety of a protocol for noncardiac and cardiac magnetic resonance imaging of patients with permanent pacemakers and implantable-cardioverter defibrillators at 1.5 tesla. Circulation. 2006;114:1277–84.

    Article  PubMed  Google Scholar 

  30. Levine GN, Gomes AS, Arai AE, et al. Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation. 2007;116:2878–91.

    Article  PubMed  Google Scholar 

  31. Roguin A, Schwitter J, Vahlhaus C, et al. Magnetic resonance imaging in individuals with cardiovascular implantable electronic devices. Europace. 2008;10:336–46.

    Article  PubMed  Google Scholar 

  32. Nazarian S, Hansford R, Roguin A, et al. A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med. 2011;155:415–24.

    Article  PubMed  Google Scholar 

  33. Pulver AF, Puchalski MD, Bradley DJ, et al. Safety and imaging quality of MRI in pediatric and adult congenital heart disease patients with pacemakers. Pacing Clin Electrophysiol. 2009;32:450–6.

    Article  PubMed  Google Scholar 

  34. Sasaki T, Hansford R, Zviman MM, et al. Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators. Circ Cardiovasc Imaging. 2011;4:662–70.

    Article  PubMed  Google Scholar 

  35. Standard practice for marking medical devices and other items for safety in the magnetic resonance environment. American Society for Testing and Materials (ASTM) International 2008.

    Google Scholar 

  36. http://www.fda.gov/MedicalDevices/default.htm.

  37. http://www.sjmprofessional.com/Products/index.aspx.

  38. http://www.biotronikusa.com/manuals/.

  39. Wilkoff BL, Bello D, Taborsky M, et al. Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart Rhythm. 2011;8:65–73.

    Article  PubMed  Google Scholar 

  40. Forleo GB, Santini L, Della Rocca DG, et al. Safety and efficacy of a new magnetic resonance imaging-compatible pacing system: early results of a prospective comparison with conventional dual-chamber implant outcomes. Heart Rhythm. 2010;7:750–4.

    Article  PubMed  Google Scholar 

  41. http://www.medtronic.com/mrisurescan-us/pacing_system_description.html.

  42. Gimbel JR. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla. Pacing Clin Electrophysiol. 2008;31:795–801.

    Article  PubMed  Google Scholar 

  43. Gimbel JR. Unexpected asystole during 3T magnetic resonance imaging of a pacemaker-dependent patient with a ‘modern’ pacemaker. Europace. 2009;11:1241–2.

    Article  PubMed  Google Scholar 

  44. Gimbel JR. Unexpected pacing inhibition upon exposure to the 3T static magnetic field prior to imaging acquisition: what is the mechanism? Heart Rhythm. 2011;8:944–5.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

Dr. Nazarian is on the MRI advisory panel (unpaid) for Medtronic. Dr. Nazarian is a scientific advisor to and is principal investigator for research funding to Johns Hopkins University from Biosense Webster Inc. Dr. Nazarian is funded by the National Institutes of Health Career Development Grant K23HL089333.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Roy Beinart MD .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2014 Springer Science+Business Media New York

About this chapter

Cite this chapter

Beinart, R., Nazarian, S. (2014). Cardiac MR in Patients with Implantable Arrhythmia Devices. In: Saremi, F. (eds) Cardiac CT and MR for Adult Congenital Heart Disease. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-8875-0_31

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-8875-0_31

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-8874-3

  • Online ISBN: 978-1-4614-8875-0

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics