Abstract
Knee replacement surgery is a challenging, invasive procedure, so it is prudent that reliable components are used to minimize the likelihood of implant failure and subsequent risky, post-operation corrections. Each artificial component is adhered to a bone interface by composite acrylic-based cement. It is theorized that the structural integrity and, by extension, longevity of bone cement used to fill voids in knee replacement surgery is augmented by adjuvant screws embedded in the cement and anchored in bone, analogous to rebar-reinforced concrete. While the screw fixation method has exhibited positive results in arthroplasty patients, no conclusive evidence has been produced demonstrating its value over cement without screw fixation. It was the purpose of this research to examine which, if either, method is more effective. Porous polyurethane blocks were used to emulate human bones, in which uniform defects were generated and filled with bone cement in two cases, with and without the addition of screws. To test their mechanical properties, the specimens were loaded in compression by a material testing machine to mimic the forces created by the body, with focus on micro-motion of the cement. Additionally, nondestructive damage detection techniques were performed during fatigue testing by high frequency interrogation using piezoceramic actuators and sensors. Damage detection and classification algorithms were explored from attained data.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Ritter M, Harty L (2004) Medial screws and cement: a possible mechanical augmentation in total knee arthroplasty. J Arthroplast 19(5):587–589
Amer L, Stone B, Warren C, Cornwell P, Meneghini RM (2009) Initial mechanical stability of cementless highly-porous titanium tibial components. In: Proceedings of the IMAC-XXVII
Inman D, Cudney H (2000) Structural and machine design using piezoceramic materials, a guide for structural design engineers. NASA report, grant no. NAG-1-1998, April 2000
Doebling S, Farrar C (1998) A summary review of vibration-based damage identification methods. Shock Vib Dig 30(2):91–105
Farrar C, Worden K (2007) An introduction to structural health monitoring. Philos Trans R Soc A 365(1851):303–315
Sohn H, Farrar C, Hemez F, Shunk D, Stinemates D, Nadler B, Czamecki J (2004) A review of structural health monitoring literature: 1996–2001. Los Alamos National Laboratory report, LA-13976-MS
Acknowledgements
The authors would like to acknowledge support for this work provided by Los Alamos National Laboratory as part of the Los Alamos Dynamic Summer School. Additionally, the authors extend thanks to Manny Lovato of Materials Science and Technology at Los Alamos National Laboratory for his help and guidance performing the mechanical testing.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 The Society for Experimental Mechanics, Inc.
About this paper
Cite this paper
Keyser, R., Migliori, R., Morgan, T., Anton, S.R., Fariholt, K.M., Meneghini, R.M. (2013). Mechanical Strength of Bone Cement with and Without Adjuvant Screw Fixation. In: Allemang, R., De Clerck, J., Niezrecki, C., Wicks, A. (eds) Special Topics in Structural Dynamics, Volume 6. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-6546-1_3
Download citation
DOI: https://doi.org/10.1007/978-1-4614-6546-1_3
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-6545-4
Online ISBN: 978-1-4614-6546-1
eBook Packages: EngineeringEngineering (R0)