Skip to main content

Mechanical Strength of Bone Cement with and Without Adjuvant Screw Fixation

  • Conference paper
  • First Online:
Special Topics in Structural Dynamics, Volume 6

Abstract

Knee replacement surgery is a challenging, invasive procedure, so it is prudent that reliable components are used to minimize the likelihood of implant failure and subsequent risky, post-operation corrections. Each artificial component is adhered to a bone interface by composite acrylic-based cement. It is theorized that the structural integrity and, by extension, longevity of bone cement used to fill voids in knee replacement surgery is augmented by adjuvant screws embedded in the cement and anchored in bone, analogous to rebar-reinforced concrete. While the screw fixation method has exhibited positive results in arthroplasty patients, no conclusive evidence has been produced demonstrating its value over cement without screw fixation. It was the purpose of this research to examine which, if either, method is more effective. Porous polyurethane blocks were used to emulate human bones, in which uniform defects were generated and filled with bone cement in two cases, with and without the addition of screws. To test their mechanical properties, the specimens were loaded in compression by a material testing machine to mimic the forces created by the body, with focus on micro-motion of the cement. Additionally, nondestructive damage detection techniques were performed during fatigue testing by high frequency interrogation using piezoceramic actuators and sensors. Damage detection and classification algorithms were explored from attained data.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Ritter M, Harty L (2004) Medial screws and cement: a possible mechanical augmentation in total knee arthroplasty. J Arthroplast 19(5):587–589

    Article  Google Scholar 

  2. Amer L, Stone B, Warren C, Cornwell P, Meneghini RM (2009) Initial mechanical stability of cementless highly-porous titanium tibial components. In: Proceedings of the IMAC-XXVII

    Google Scholar 

  3. Inman D, Cudney H (2000) Structural and machine design using piezoceramic materials, a guide for structural design engineers. NASA report, grant no. NAG-1-1998, April 2000

    Google Scholar 

  4. Doebling S, Farrar C (1998) A summary review of vibration-based damage identification methods. Shock Vib Dig 30(2):91–105

    Article  Google Scholar 

  5. Farrar C, Worden K (2007) An introduction to structural health monitoring. Philos Trans R Soc A 365(1851):303–315

    Article  Google Scholar 

  6. Sohn H, Farrar C, Hemez F, Shunk D, Stinemates D, Nadler B, Czamecki J (2004) A review of structural health monitoring literature: 1996–2001. Los Alamos National Laboratory report, LA-13976-MS

    Google Scholar 

Download references

Acknowledgements

The authors would like to acknowledge support for this work provided by Los Alamos National Laboratory as part of the Los Alamos Dynamic Summer School. Additionally, the authors extend thanks to Manny Lovato of Materials Science and Technology at Los Alamos National Laboratory for his help and guidance performing the mechanical testing.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Steven R. Anton .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 The Society for Experimental Mechanics, Inc.

About this paper

Cite this paper

Keyser, R., Migliori, R., Morgan, T., Anton, S.R., Fariholt, K.M., Meneghini, R.M. (2013). Mechanical Strength of Bone Cement with and Without Adjuvant Screw Fixation. In: Allemang, R., De Clerck, J., Niezrecki, C., Wicks, A. (eds) Special Topics in Structural Dynamics, Volume 6. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-6546-1_3

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-6546-1_3

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-6545-4

  • Online ISBN: 978-1-4614-6546-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics