Abstract
Missing teeth is a common problem worldwide, the incidence of which is on the rise year after year. For example, in China, there are more than 800 million missing teeth in people who are over 65 years old [1]. Not only does the loss of teeth affect one’s aesthetic appearance, but it may also lead to other complications, such as dysphonia and temporomandibular joint disorder.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Qi XQ (2008) The third national epidemiological survey report of oral health. People’s Medical Publishing House, Beijing
Http://www.marketsandmarkets.com/Market-Reports/dental-implants-prosthetics-market-695.html
Brånemark P-I, Breine U, Adell R, Hansson BO, Lindstrom J, Olsson A (1969) Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 3:81–100
Brånemark P-I, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O et al. (1977) Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg 16(11):1–132
Schroeder A, Pohler O, Sutter F (1976) Gewebsreaktion auf ein Titan-Hohlzylinderimplantat mit Titan-Spritzschichtoberflache. Schweiz Monatsschr Zahnheilk 86:713–727
Schroeder A, Stich H, Straumann F, Sutter F (1978) Ueber die Anlagerung von Osteozement an einen belasteten Implantatkorper. Schweiz Monatsschr Zahnheilk 88:1051–1057
Franchi M, Fini M, Martini D, Orsini E, Leonardi L, Ruggeri A, Giavaresi G, Ottani V (2005) Biological fixation of endosseous implants. Micron 36:665–671
Joos U, Wiesmann HP, Szuwart T, Meyer U (2006) Mineralization at the interface of implants. Int J Oral Maxillofac Surg 35:783–790
Wijaya SK, Oka H, Saratani K et al (2004) Development of implant movement checker for determining dental implant stability. Med Eng Phys 26:513–522
Barry M, Kennedy D, Keating K et al (2005) Design of dynamic test equipment for the testing of dental implants. Mater Des 26:209–216
Macro V, Robert M, Marek B, Massimiliano B, Luca C (2000) Large-sliding contact elements accurately predict levels of bone-implant micromotion relevant to osteointegration. J Biomech 33:1611–1618
Waterhouse RB (1981) Fretting fatigue. Applied Science, London
Zhou ZR, Vincent L (1995) Mixed fretting regime. Wear 181–183:531–536
Yu HY, Zhou ZR (2005) Fretting behavior of cortical bone against titanium and its alloy. Wear 259:910–918
Zhu MH, Zhou ZR (2001) An experimental study on radial fretting behavior. Tribol Int 34:321–326
Yu HY, Quan HX, Cai ZB, Gao SS, Zhu MH (2008) Radial fretting behaviour of cortical bone against titanium. Tribol Lett 31:69–76
Batten RL (1982) Bone repair and fracture healing in man. Injury 13:532–533
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer Science+Business Media New York
About this chapter
Cite this chapter
Zhou, ZR., Yu, HY., Zheng, J., Qian, LM., Yan, Y. (2013). Fretting Failure of Dental Implant–Bone Interface. In: Dental Biotribology. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-4550-0_7
Download citation
DOI: https://doi.org/10.1007/978-1-4614-4550-0_7
Published:
Publisher Name: Springer, New York, NY
Print ISBN: 978-1-4614-4549-4
Online ISBN: 978-1-4614-4550-0
eBook Packages: EngineeringEngineering (R0)