Skip to main content

Assessment of Effective Prestress Force of PCCV Usinig Si Technique

  • Conference paper
  • First Online:
Engineering Applications of Residual Stress, Volume 8

Abstract

Bonded tendons have been used in reactor buildings of heavy water reactors and the light water reactors of some nuclear power plants operating in Korea. The assessment of prestressed forces on those bonded tendons is becoming an important issue in assuring their continuous operation beyond their design life. In order to assess the effective prestressed force on the bonded tendon, indirect assessment techniques have been applying to the test beams which were manufactured on construction time. Therefore, this research mainly forced to establish the assessment methodology to measure directly the effective prestressed force on the bonded tendon of containment buildings using System Identification (SI) technique. To accomplish this purpose, simple SI method was proposed and adapted three dimensional finite element analysis of the 1:4 scale prestressed concrete containment vessel (PCCV) tested by Sandia nation Laboratory in 2000.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. D.J. Naus, et. Al., Report on Aging of Nuclear Power plant Reinforced Concrete Structures, NUREG/CR-6424, 1996.

    Google Scholar 

  2. Simulia Inc., Abaqus Ver.6.9-1 users manual, 2009.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hong-Pyo Lee .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 The Society for Experimental Mechanics, Inc.

About this paper

Cite this paper

Lee, HP., Jang, JB., Hwang, KM., Song, YC. (2011). Assessment of Effective Prestress Force of PCCV Usinig Si Technique. In: Proulx, T. (eds) Engineering Applications of Residual Stress, Volume 8. Conference Proceedings of the Society for Experimental Mechanics Series. Springer, New York, NY. https://doi.org/10.1007/978-1-4614-0225-1_15

Download citation

  • DOI: https://doi.org/10.1007/978-1-4614-0225-1_15

  • Published:

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4614-0224-4

  • Online ISBN: 978-1-4614-0225-1

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics