Skip to main content

Thromboembolism in Children with ST. JUDE MEDICAL® Valves Maintained on Aspirin and PERSANTINE®

  • Chapter
  • 49 Accesses

Abstract

Twenty-five consecutive pediatric patients underwent the insertion of 27 ST. JUDE MEDICAL® valves in a nonrandomized clinical trial. All were managed with aspirin and PERSANTINE® postoperatively. Five thromboembolic events (TE) were observed in the 25 patients during a total of 199 patient-months of follow-up. This represents a 20% TE incidence and extrapolates to 30.1 TE events per 100 patient-years. Based on these data, all children are now placed on COUMADIN® therapy. We recommend COUMADIN anticoagulation in all children with the ST. JUDE MEDICAL valve and suggest a cooperative multicenter trial to help resolve the issue.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD   169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Gardner TJ, Roland JMA, Neill CA, et al: Valve replacement in children: A fifteen year experience. J Thorac Cardiovasc Surg 1982; 83, 178–185.

    PubMed  CAS  Google Scholar 

  2. Donahoo JS, Gardner TJ: St. Jude Medical valve prostheses in infants and children. S Med J 1982; 75, 1538–1540.

    Article  CAS  Google Scholar 

  3. Human G., Jaffe HS, Fraser CB, et al: Mitral valve replacement in children. J Thorac Cardiovasc Surg 1982; 83, 873–877.

    PubMed  CAS  Google Scholar 

  4. Lomeo A, Patene L, Gentile M, et al: Aortic valve replacement with St. Jude valve without long term anticoagulants: A prospective study, in DeBakey ME (ed): Advances in Cardiac Valves: Clinical Perspectives, New York, Yorke Medical Books, 1983, pp 170–172.

    Google Scholar 

  5. Pass HI, Sade RM, Crawford FA, et al: St. Jude Prostheses without anticoagulation in Children. Am J Card 1982; 49, 1035.

    Article  Google Scholar 

  6. Smith JM, Cooley DA, Ott DA, et al: Aortic valve replacement in preteenage children. Ann Thorac Surg 1980; 29, 512–518.

    Article  PubMed  Google Scholar 

  7. Geha AS: Valve replacement in children. Ann Thorac Surg 1980; 29, 500–501.

    Article  PubMed  CAS  Google Scholar 

  8. Baudet EM: Cardiac valve replacement in children with St. Jude Medical prosthesis, in DeBakey ME (ed): Advances in Cardiac Valves: Clinical Perspectives, New York, Yorke Medical Books, 1983, pp 149–155.

    Google Scholar 

  9. Nicoloff DM, Arom KV, Lindsay WG, et al: Techniques for implantation of the St. Jude valve in the aortic and mitral positions, in Debakey ME (ed): Advances in Cardiac Valves: Clinical Perspectives. New York, Yorke Medical Books, 1983, pp 191–196.

    Google Scholar 

  10. Williams WG, Pollock JC, Geiss DM, et al: Experience with aortic and mitral valve replacement in children. J Thorac Cardiovasc Surg 1981; 81: 326–333.

    PubMed  CAS  Google Scholar 

  11. Matthews RA, Park SC, Neches WH, et al: Valve replacement in children and adolescents. J Thorac Cardiovasc Surg 1977; 73: 872–878.

    Google Scholar 

  12. Geha AS, Laks H, Stansel HC et al: Late failure of porcine valve heterografts in children. J Thorac Cardiovasc Surg 1979; 78: 351–364.

    PubMed  CAS  Google Scholar 

  13. Wada J, Yokoyama M, Hashimoto A, et al: Long term followup of artificial heart valves in patients under 15 years old. Ann Thorac Surg 1979; 29: 519–520.

    Article  Google Scholar 

  14. Dunn JM: Porcine valve durability in children. Ann Thorac Surg 1981; 32: 357–368.

    Article  PubMed  CAS  Google Scholar 

  15. Williams WG, Pollock JC, Geiss DM, et al: Experience with aortic and mitral valve replacement in children. J Thorac Cardiovasc Surg 1981; 81: 326–333.

    PubMed  CAS  Google Scholar 

  16. Fiddler GI, Gerlis LM, Walker DR, et al: Calcification of glutaraldehyde-preserved porcine and bovine xenograft valves in young children. Ann Thorac Surg 1983; 35: 257–261.

    Article  PubMed  CAS  Google Scholar 

  17. Walker WE, Duncan JM, Frazier OH, et al: Early experience with the Ionescu-Shiley pericardial xenograft valve: Accelerated calcification in children. J Thorac Cardiovasc Surg 1983; 86: 570–575.

    PubMed  CAS  Google Scholar 

  18. Crupi G, Gibson D, Heard B, et al: Severe late failure of a porcine xenograft mitral valve: Clinical, echocardiographic and pathological findings. Thorax 1980; 35: 210–212.

    Article  PubMed  CAS  Google Scholar 

  19. Cuicio CA, Commerford PJ, Rose AG, et al: Calcification of glutaraldehyde-perserved porcine xenografts in young patients. J Thorac Cardiovasc Surg 1981; 81: 621–625.

    Google Scholar 

  20. Lillehei CW: Worldwide experience with the St. Jude Medical valve prosthesis: Clinical and hemodynamic results. Contemp Surg 1982; 20: 17–32.

    Google Scholar 

  21. Wortham DC, Tri TB, Bowen TE: Hemodynamic evaluation of the St. Jude Medical valve prosthesis in the small aortic annulus. J Thorac Cardiovasc Surg 1981; 81: 615–620.

    PubMed  CAS  Google Scholar 

  22. Nicoloff DM, Emery RW, Arom KV, et al: Clinical and hemodynamic results with the St. Jude Medical cardiac valve prosthesis. J Thorac Cardiovasc Surg 1981; 82: 674–683.

    PubMed  CAS  Google Scholar 

  23. Chaux A, Gray RG, Matloff JM, et al: An appreciation of the new St. Jude valvular prosthesis. J Thorac Cardiovasc Surg 1981; 81: 202–211.

    PubMed  CAS  Google Scholar 

  24. Moggio RA, Hammond GL, Stansel HC, et al: Incidence of emboli with cloth-covered Starr-Edwards valve without anticoagulation and with varying forms of anticoagulation. J Thorac Cardiovasc Surg 1978; 75: 296–299.

    PubMed  CAS  Google Scholar 

  25. St. John Sutton MG, Miller GAH, Oldershaw PJ, et al: Anticoagulants and the Bjork-Shiley prosthesis: Experience of 390 patients. Br Heart J 1978; 40: 558–562.

    Article  Google Scholar 

  26. Nunez L, Aguado MG, Celemin D, et al: Aspirin or Coumadin as the drug of choice for valve replacement with porcine bioprosthesis. Ann Thorac Surg 1982; 33: 354–358.

    Article  PubMed  CAS  Google Scholar 

  27. Horstkotte D, Korfer R, Seipel L, et al: Late complications in patients with Bjork-Shiley and St. Jude Medical heart valve replacement. Circulation 1983; 68 (Supp II):11-175–11-184.

    Google Scholar 

  28. Nunez L, Iglesias A, Sotillo J: Entrapment of leaflet of St. Jude Medical cardiac valve prosthesis by miniscule thrombus: Report of two cases. Aim Thorac Surg 1980; 29: 567–569

    Article  Google Scholar 

  29. Sharma A, Johnson DC, Cartmill TB: Entrapment of both leaflets of St. Jude Medical aortic valve prosthesis in a child. J Thorac Cardiovasc Surg 1983; 86: 453–454.

    PubMed  CAS  Google Scholar 

  30. Moulton AL, Singleton RT, Oster WF, et al: Fatal thrombosis of an aortic St. Jude Medical valve despite “adequate” anticoagulation. J Thorac Cardiovasc Surg 1982; 83: 472–473.

    PubMed  CAS  Google Scholar 

  31. Subramanian S: Use of the St. Judge Medical prosthesis in children, in DeBakey ME (ed): Advances in Cardiac Valves: Clinical Perspectives. New York, Yorke Medical Books, 1983; pp 129–137.

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1985 Martinus Nijhoff Publishing, Boston

About this chapter

Cite this chapter

Boe, S.L., Mcnicholas, K.W., Olivier, H.F., Niguidula, F.N., Magovern, G.J., Lemole, G.M. (1985). Thromboembolism in Children with ST. JUDE MEDICAL® Valves Maintained on Aspirin and PERSANTINE® . In: Matloff, J.M. (eds) Cardiac Valve Replacement. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-2601-4_18

Download citation

  • DOI: https://doi.org/10.1007/978-1-4613-2601-4_18

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4612-9629-4

  • Online ISBN: 978-1-4613-2601-4

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics