Abstract
This chapter discusses important microbiologic considerations of dialyzer reuse. The terms sterilization and disinfection are defined especially in the context of dialyzer reuse, and microbiologic guidelines are described that are applied to water used to prepare dialysis fluid in contradistinction to water employed for rinsing dialyzers and preparing chemical germicide solutions in dialyzer reuse programs. Guidelines pertaining to bacterial endotoxin and chemicals in waters also are discussed.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Alter MJ, Favero MS, Petersen NJ, Doto IL, Leger RT, Maynard JE: National surveillance of dialysis-associated hepatitis and other diseases 1976 and 1980. Dial Transplant 12: 860–868, 1983.
Favero MS: Chemical disinfection of medical and surgical materials. In: Block SS (ed Disinfection, sterilization and preservation, 3rd edn. Lea and Febiger, Philadelphia, 1983, pp 469–492.
Favero MS, Petersen NJ: Microbiological guidelines for hemodialysis systems. Dial Trans-plant 6: 34–36, 1977.
Association for the Advencement of Medical Instrumentation: American national standard for hemodialysis systems. Association for the Advancement of Medical Instrumentation, Arlington VA, 1981.
Petersen NJ: Microbiologic hazards associated with reuse of hemodialyzers. In: Proceedings of national workshop on reuse of consumables in hemodialysis. Kidney Disease Coalition, Baltimore, 1982, pp 121–129.
Carson LA, Petersen NJ, Favero MS, Aguero SM: Growth characteristics of atypical mycobacteria in water and their comparative resistance to disinfectants. Appl Environ Microbiol 36: 839–846, 1978.
Bolan G.A,. Reingold AL, Carson LA, et al.: Infections with Mycobacterium chelonei in patients receiving dialysis and using processed hemodialyzers. J. Infect. Dis. 152: 1013–1019, 1985.
Bland LA, Alter MJ, Favero MS, Carson LA, Cusick LB: Hemodialyzer reuse: practices in the United States and implication for infection control. Trans Am Soc Artif Intern Organs 31: 556–559 1985.
Favero MS: Distinguishing between high-level disinfection, reprocessing, and sterilization. AAMI Technology Assessment Report no. 6-83. Association for the Advancement of Medical Instrumentation, Arlington VA, 1983.
Health Care Financing Administration: National listing of providers furnishing kidney dialysis and transplant services. Baltimore, 1983.
Food and Drug Administration Medical Device Standards Publication Technical Report: Investigation of the risks and hazards associated with hemodialysis devices. Contract 223-78-5046, April 1980.
Petersen NJ, Carson LA, Favero MS: Bacterial endotoxin in new and reused hemodialyzers: a potential cause of endotoxemia. Trans Am Soc Artif Intern Organs 27: 155–160, 1981.
Schreeder MT, Favero MS, Hughes JR, Petersen NJ, et al.: Dialysis encephalopathy and aluminum exposure: an epidemiologic analysis. J Chronic Dis 36: 581–593, 1983.
Environmental Protection Agency: National primary drinking water regulations: volatile synthetic organic chemicals; proposed rulemaking. Fed Register 49: 24330–24355, 1984.
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1986 Martinus Nijhoff Publishing
About this chapter
Cite this chapter
Favero, M.S., Bland, L.A. (1986). Microbiologic Principles Applied to Reprocessing Hemodialyzers. In: Deane, N., Wineman, R.J., Bemis, J.A. (eds) Guide to Reprocessing of Hemodialyzers. Developments in Nephrology, vol 15. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-2313-6_4
Download citation
DOI: https://doi.org/10.1007/978-1-4613-2313-6_4
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4612-9423-8
Online ISBN: 978-1-4613-2313-6
eBook Packages: Springer Book Archive