Abstract
Although the application of electrical energy to the heart had been investigated in the 18th century, it was not until the first half of the 20th century that reference was made to the clinical use of electrical shocks to revert abnormal cardiac rhythms. Several recent reviews have summarized historical milestones in the development of devices capable of delivering specified electrical charges to the heart [1–4]. Early studies utilized alternating current (AC), employing 60-cycle AC of 1.5 to 2.0 amperes and 120 to 130 volts. Although AC discharges are capable of transthoracic defibrillation of the human heart, they are not suitable for correcting arrhythmias in man because they may lead to substantial deterioration in ventricular function and expose the patient to the risk of ventricular fibrillation [5]. The development of capacitors capable of delivering single-pulse discharges set the stage for the production of the cardioversion/defibrillation apparatus in use today (figure 7–1).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Lown B: Electrical reversion of cardiac arrhythmias. Br Heart J 29: 469–489, 1967.
Resnekov L, McDonald L: Appraisal of electro-conversion in treatment of cardiac dysrhythmias. Br Heart J 30: 786–811, 1968.
Resnekov L: Theory and practice of elec-troversion of cardiac dysrhythmmias. Med Clin N Am 60: 325–342, 1976.
DeSilva RA, Graboys TB, Podrid PJ, Lown B: Cardioversion and defibrillation. Am Heart J 100: 881–895, 1980.
Lown B, Neuman L, Amarasingham R, Berko-vits B: Comparison of alternating current with direct current electroshock across the closed chest. Am J Cardiol 10: 223–233, 1962.
Edmark KW: Simultaneous voltage and current waveforms generated during internal and external direct current pulse defibrillation. Surg. Forum 14: 262–264, 1963.
Geddes LA: The use of the defibrillator. In Coronary Care, Karliner JS, Gregoratos G (eds), New York, Churchill Livingstone, 1981, pp 391–424.
Pantridge JF, Adgey AAJ, Webb SW, Anderson J: Electrical requirements for ventricular defibrillation. Br Med J 2: 313–315, 1975.
Rossi M, Lown B: The use of quinidine in cardioversion Am J Cardiol 19: 234–238 1967.
Södermark T, Edhag O, Sjogren A, et al: Effect of quinidine on maintaining sinus rhythm after conversion of atrial fibrillation or flutter. Br Heart J 37: 486–492, 1975.
Kerber RE, Jensen SR, Grayzel J, Kennedy J, Hoyt R: Elective cardioversion: Influence of paddle-electrode location and size on success rates and energy requirements. N Engl J Med 305: 658–662, 1981.
Lown B, Kleiger R, Wolff G: The technique of cardioversion Am Heart J 67: 282–284, 1964.
Morris JJ Jr, Kong Y, North WC, Mclntosh HD: Experience with “cardioversion” of atrial fibrillation and flutter. Am J Cardiol 14: 94–100, 1964.
Crampton R: Accepted, controversial, and speculative aspects of ventricular defibrillation. Progr Cardiovasc Dis 23: 167–186, 1980.
Diack AW, Welborn WS, Rullman RG, et al: An automatic cardiac resuscitator for emergency treatment of cardiac arrest. Med Instr 13:78, 1979.
Resnekov L, McDonald L: Electroversion of lone atrial fibrillation and flutter including haemodynamic studies at rest and on exercise. Br Heart J 33: 339–350, 1971.
Guiney TE, Lown B: Electrical conversion of atrial flutter to atrial fibrillation. Flutter mechanism in man. Br Heart J 34: 1215–1224, 1972.
Pennington JE, Taylor J, Lown B: Chest thump for reverting ventricular tachycardia. N Engl J Med 283: 1192–1195, 1970.
Surawicz B: Ventricular fibrillation. Am J Cardiol 28: 268–287, 1971.
Garrey WE: The nature of fibrillary contraction of the heart — its relation to tissue mass and form. Am J Pbysiol 33: 397–414, 1914.
Zipes D, Fischer J, King RM, Nicol AB, Jolly WW: Termination of ventricular fibrillation in dogs by depolarizing a critical mass of myocardium. Am J Cardiol 36: 37–44, 1975.
Grace WJ, Kennedy RJ, Nolte CT: Blind defibrillation. Am J Cardiol 34:115, 1974.
Weaver WD, Cobb LA, Copass MK, Hallstrom AP: Ventricular defibrillation — a comparative trial using 175—J and 320-J shocks. N Engl J Med 307: 1101–1106, 1982.
Hoyt R, Grayzel J, Kerber RE: Determinants of intracardiac current in defibrillation. Experimental studies in dogs. Circulation 64: 818–823, 1981.
Kerber RE, Grayzel J, Hoyt R, Marcus M, Kennedy J: Transthoracic resistance in human defibrillation. Influence of body weight, chest size, serial shocks, paddle size and paddle contact pressure. Circulation 63: 676–682, 1981.
Gutgesell HP, Tacker WA, Geddes LA, Davis JS, Lie JT, McNamara DG: Energy dose for ventricular defibrillation in children. Pediatrics 58:898, 1976.
Mirowski M, Mower MM, Langer A, et al: A chronically implanted system for automatic defibrillation in active conscious dogs; experimental model for treatment of sudden death from ventricular fibrillation. Circulation 58: 90–94, 1978.
Mirowski M, Reid PR, Mower MM, et al: Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med 303: 322–324, 1980.
Reid P, Mirowski M, Mower MM, Griffith LSC, Platia E, Watkins L: Treatment of ventricular tachycardias with an R-wave synchronized automatic implantable defibrillator. Circulation 66 (Suppl II):II-216, 1982.
Winkle RA, Imran M, Bach SM, Jr: The implant-able defibrillator: Accurate detection of ventricular tachyarrhythmias by a new bipolar rate detection circuit. Circulation 66 (Suppl II):II-217, 1982.
Resnekov L, McDonald L: Complications in 220 patients with cardiac dysrhythmias treated by phased direct current shock, and indications for electroconversion. Br Heart J 29: 926–936, 1967.
Pugh BR, Buja LM, Parkey RW, et al: Cardioversion and “false positive” technetium-99m stannous pyrophosphate myocardial scintigrams. Circulation 54: 399–403, 1976.
Lown B, Wittenberg S: Cardioversion and digitalis III. Effect of change in serum potassium concentration. Am J Cardiol 21: 513–517, 1968.
Goldman MJ: The management of chronic atrial fibrillation Progr Cardiovasc Dis 2: 465, 1960.
Ikram H, Nixon PGF, Arcan T: Left atrial function after electrical conversion to sinus rhythm. Br Heart J 30: 80, 1968.
Rowlands DJ, Logan WFWE, Howitt G: Atrial function after conversion. Am Heart J 74: 149, 1967.
Logan WFWE, Rowlands DJ, Howitt G, Holmes AM: Left atrial activity following cardioversion. Lancet 2:471, 1965.
Bjerkelund CJ, Orning OM: The efficacy of anticoagulant therapy in preventing embolism related to DC electrical conversion of atrial fibrillation. Am J Cardiol 23: 208–216, 1969.
Resnekov L: High-energy electrical current in the management of cardiac dysrhythmias. In Cardiac Arrhythmias: Their Mechanisms, Diagnosis and Management, Mandell WJ (ed). Philadelphia, JB Lippincott, 1980, pp 589–604.
Horn H, Lown B: Cardioversion 1975: Foremost therapy for tachyarrhythmias. Geriatrics 30: 75–82, 1975.
Zipes DF, Jackman WM, Heger JJ, et al: Clinical transvenous cardioversion of recurrent life-threatening ventricular tachyarrhythmias: Low energy synchronized cardioversion of ventricular tachycardia and termination of ventricular fibrillation in patients using a catheter electrode. Am Heart J 103:789, 1982.
Zipes DP, Heger JJ, Miles WM, Mahomed Y, Brown JW, Spielman SR, Prystowsky EN: Early experience with an implantable cardioverter. N Engl J Med 311:485, 1984.
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 1986 Martinus Nijhoff Publishing, Boston.
About this chapter
Cite this chapter
Antman, E.M., Rutherford, J.D. (1986). Cardioversion and Defibrillation. In: Coronary Care Medicine. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-2303-7_7
Download citation
DOI: https://doi.org/10.1007/978-1-4613-2303-7_7
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4612-9418-4
Online ISBN: 978-1-4613-2303-7
eBook Packages: Springer Book Archive