Abstract
The radioactive microsphere technique is the most accurate method currently available for measuring regional myocardial perfusion in experimental animals. It is based on the principle that microspheres distributei n proportion to regional myocardial blood flow if the basic criteria of the technique are satisfied (1). However, this assumption is not substantiated since microsphere distribution is determined indirectly from measurements of tissue radioactivity. Furthermore, the use of relatively large tissue samples for accurate measurements decreases spatial resolution and, therefore, prevents studies of regional myocardial perfusion in smaller animals.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsPreview
Unable to display preview. Download preview PDF.
References
Heymann, M.A., Payne, B.D., Hoffman, J.I.E. and Rudolph, A.M. Prog. Cardiovasc. Dis. 20: 55–79, 1977.
Poujeo1, P., Chabardés, D., Bonvalet, J. P. and de Rouffignac, C. Pflűgers Arch. 357: 291–301, 1975.
Wisnes, A. and Kirkebo, A. Acta Physiol. Scand. 96: 256–266, 1976.
Vetterlein, F. and Schmidt, G. Basic Res. Cardiol. 75: 526–536, 1980.
Vetterlein, F., Halfter, R. and Schmidt, G. Arzneim.-Forsch. 29: 747–751, 1979.
Shell, W., Kligerman, M., Chang, B.-L., See, J., Meerbaum, S. and Corday, E. Circ. 72 (Supp. III): 191, 1985.
Wicker, P. and Tarazi, R.C. Am. J. Physiol. 242: H94–H97, 1982.
Flaim, S.F., Nellis, S.H., Toggart, E.J., Drler, H., Kanda, K. and Newman, E.D. J. Pharmacol. Methods 11: 1–39, 1984.
Kirk, R.E. Experimental design: procedures for the behavioural sciences. 2nd ed. Brooks/Cole Pub. Co., Monterey, Calif., 1982.
Vetterlein, F. Basic Res. Cardiol. 70: 401–405, 1975.
Wicker, P. and Tarazi, R.C. Cardiovasc. Res. 16: 580–586, 1982.
Kobrin, I., Kardon, M.B., Oigman, W., Pegram, B.L. and Frohlich, E.D. Am. J. Physiol. 247: H35–H39, 1984.
Tuma, R.F., Vasthare, U.S., Irion, G.l. and Wiedeman, M.P. Am. J. Physiol. 250: HI37–H143, 1986.
Phibbs, R. H. and Dong, L. Can. J. Physiol. Pharmacol. 48: 415–421, 1970.
Harell, G.S., Dickhoner, W.A. and Breiman, R.S. Microvasc. Res. 13: 203–210, 1977.
Eng, C., Cho, S., Factor, S.M., Sonnenblick, E.H. and Kirk, E.S. Circ. Res. 54: 74–82, 1984.
Wicker, P. Personal communication.
Stanek, K.A., Smith, T.l., Murphy, W.R. and Coleman, T.G. Am. J. Physiol. 245: H920–H923, 1983.
Tsuchiya, M., Walsh, G.M. and Frohlich, E.D. Am. J. Physiol. 233: H617–H621, 1977.
Baer, R.W., Payne, B.D., Verrier, E.D., Vlahakes, G.J., Molodowitch, D., Uhlig, P.N. and Hoffman, J.I.E. Am. J. Physiol. 246: H418–H434, 1984.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1987 Springer Science+Business Media Dordrecht
About this chapter
Cite this chapter
Korpan, M., Rakusan, K. (1987). Morphometric Analysis of Regional Myocardial Perfusion in Rats as Measured by Non-Radioactive Microspheres. In: Dhalla, N.S., Innes, I.R., Beamish, R.E. (eds) Myocardial Ischemia. Developments in Cardiovascular Medicine, vol 67. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-2055-5_13
Download citation
DOI: https://doi.org/10.1007/978-1-4613-2055-5_13
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4612-9221-0
Online ISBN: 978-1-4613-2055-5
eBook Packages: Springer Book Archive