In Vivo Calibration of a Transcutaneous Oxygen Electrode in Adult Patients

  • Chapter

Part of the book series: Advances in Experimental Medicine and Biology ((ABBI,volume 7))

Summary

Transcutaneous oxygen tension (tcPO2) has been compared with arterial oxygen tension (PaO2 in 14 haemodynamically stable patients in an intensive care unit. Two calibration methods have been compared: (1) “In vitro” calibration, a two point calibration procedure carried out before attachment to the skin. (2) “In vivo” calibration, calibration using a single arterial sample, to recalibrate the upper point after attachment of the electrode to the skin and stabilisation of the electrical output. After “in vitro” calibration the regression equation was given by tcPO2 (mmHg) =0.58 PaO2 +13.4 (95% confidence limits + 19.6). After “in vivo” calibration, the regression equation for 55 comparisons over the range 50 to 120mmHg was given by: tcPO2 (mmHg) = 0.98 PaO2 + 1.6 (95% confidence limits + 6.6). The “in vivo” calibration method therefore allows a close estimate of PaO2 to be made from tcPO2 values in adult patients providing strict operating criteria observed.

This is a preview of subscription content, log in via an institution.

Buying options

Chapter
USD   29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD   39.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD   54.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Learn about institutional subscriptions

References

  1. DCS Hutchison, G Rocca and D Honeybourne. Estimation of oxygen tension in adult subjects using a transcutaneous electrode. Thorax. 36: 473. (1981)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1987 Plenum Press, New York

About this chapter

Cite this chapter

Gray, B.J., Heaton, R.W., Henderson, A., Hutchison, D.C.S. (1987). In Vivo Calibration of a Transcutaneous Oxygen Electrode in Adult Patients. In: Huch, A., Huch, R., Rooth, G. (eds) Continuous Transcutaneous Monitoring. Advances in Experimental Medicine and Biology, vol 7. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-1927-6_13

Download citation

  • DOI: https://doi.org/10.1007/978-1-4613-1927-6_13

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4612-9071-1

  • Online ISBN: 978-1-4613-1927-6

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics