Automated Bone Lead Analysis by K-X-Ray Fluorescence for the Clinical Environment

  • D. E. Burger
  • F. L. Milder
  • P. R. Morsillo
  • B. B. Adams
  • H. Hu
Part of the Basic Life Sciences book series (BLSC, volume 55)

Abstract

The use of K-x-ray fluorescence (K-XRF) for measuring the content of lead in bones began over a decade ago (Ahlgren et al., 1976). In K-XRF, lead atoms are made to emit K-x-rays by exciting them with gamma radiation from a radioisotope. It was realized that extracting the signal (the fluorescence photons) from the large background (Compton scattered photons) was the chief impediment to be overcome. The use of carefully chosen geometries coupled with radioisotopes with gamma emissions of a single or few energies has succeeded in this regard (Ahlgren et al., 1976; Price et al., 1984; Somervaille et al., 1985; Jones et al., 1987). For radiation safety reasons, as well as ease of access to bone material with little overlying tissue, measurement sites are bones in the appendicular skeleton (Ahlgren et al., 1980; Somervaille et al., 1987; Somervaille et al., 1985; Chettle et al., 1989).

Keywords

Attenuation Mold Polyethylene Tungsten Coherence 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Ahlgren, I., Liden, K., Mattsson, S, Tejning, S., 1976, X-ray fluor analysis of lead in the human skeleton in vivo, Scan J Work Envir, 2: 82.Google Scholar
  2. Ahlgren, I., Haeger-Aronsen, B., Mattsson, S. and Schutz, A. 1980, In vivo determination of lead in the skeleton after occupational exposure to lead, Brit J Ind Med, 37: 109.Google Scholar
  3. Chettle, D.R., Scott, M.C. and Somervaille, L.J., Improvements in the precision of invivo bone lead measurements, PhysicsinMedicineandBiology. In PressGoogle Scholar
  4. Jones, K.W. Schidlovsky, G., Williams, F.H., Wedeen, R.P. and Batuman, V., 1987, In vivo determination of tibial lead by K-X-Ray fluorescence with a Cd-109 source, In: “In vivo Body Composition Studies, Proceedings of an International Symposium” K.J. Ellils, S. Yasamura, W.D. Morgan, eds., Bocardo Press Limited, Oxford: 363.Google Scholar
  5. Price, J., Baddeley, H., Kenardy, J.A., Thomas, B.J., Thomas, B.W., 1984, In vitro x-ray fluorescence estimation of bone lead concentrations in Queensland adults, Br J Radiol., 57: 29. Soaervaille, L.J., Chettle, D.R. and Scott, M.C., 1985, In vivo measurement of lead in bone using x-ray fluorescence, PhysMedBiol, 30:929.PubMedCrossRefGoogle Scholar
  6. Somervaille, L.J., Chettle, D.R. and Scott, M.C., 1985, In vivo measurement of lead in bone using x-ray fluorescence, Phys Med Biol, 30:929.PubMedCrossRefGoogle Scholar
  7. Somervaille, L.J., Chettle, O.R., Scott, M.C., Aufderheide, A.C., Wallgren, J.E., Wittmers, L.E. and Rapp, G.R., 1986, Comparison of two in vitro methods of bone lead analysis and the implications for in vivo measurements, Phys Med Biol, 31: 1267.PubMedCrossRefGoogle Scholar
  8. Somervaille, L.J., Chettle, D.R., Scott, M.C., Krishan, G., Browne, C.J., Aufderheide, A.C. Wittmers, I.E., and Wallgren, J., 1987, XRF of lead in vivo: Simultaneous measurement of cortical and trabecular bone In a pilot study, In: “In vivo body composition studies”, Proceedings of an International Symposium, K.J. Ellis, S. Yasumara and W.O. Morgan, eds., Bocardo Press Limited, Oxford: 325.Google Scholar
  9. Sowby, F.O., ed., 1982, Protection of the Patient in Diagnostic Radiology, In: “Annals of the ICRP”, ICRP Pub. 34, Pergamon Press, N.Y.Google Scholar
  10. Wedeen, R.P., Batuman. V., Quinless, F., Williams, F.H., Bogden, J., Schidlovsky, G. and Jones, K.J., 1987, Lead nephropathy: in vivo x-ray fluorescence for assessing body lead stores, In: “In vivo body composition studies”, Proc. of an Inter. Sym., K.J. Ellis, S. Yasumura and W.D. Morgan, eds., Bocardo Press Limited, Oxford: 357.Google Scholar

Copyright information

© Plenum Press, New York 1990

Authors and Affiliations

  • D. E. Burger
    • 1
  • F. L. Milder
    • 1
  • P. R. Morsillo
    • 1
  • B. B. Adams
    • 1
  • H. Hu
    • 2
  1. 1.ABIOMED, IncDanversUSA
  2. 2.Channing LaboratoryHarvard Medical SchoolBostonUSA

Personalised recommendations