Abstract
The future of a surgical implant depends upon the bone-material interface, both for the tolerance and function in the physiological environment (Muster and Champy, 1978).
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Bouzouita M., 1974, Etude de l’interface os-métal par diffraction et spectrométrie électronique, Thèse Doct. Chir. Dent., Strasbourg
Brenier R., Perez A., Thevenard P., Treilleux M., Capra T., 1985, Ion beam mixing of iron-titanium multilayers, Materials, Science and Engineering, 69: 83–88
Calderazzo F., Ercoli R., Natta G., 1968, Metal carbonyls: preparation structure and properties, in, “Organic Syntheses via Metal Carbonyls”, I. Wender and P. Pino, ed., Interscience Wiley Publ., New-York, 1–189
Carrière B., Deville J.P., Humbert P., 1985, Les informations chimiques obtenues par spectroscopie Auger, J. Microsc. Electron., 10: 29–61
Champy M., Lodde J.P., Schmitt R., Jaeger J.H., Muster D., 1978, Mandibular osteosynthesis by miniaturized screwed plates via a buccal approach; J. of maxillo-facial Surgery, 5: 14–21
Comte P., 1984, Metallurgical observations of biomaterials, in, “Contemporary Biomaterials”, J.W. Boretos, M. Eden, ed., Noyes Publ. Park Ridge, 66–91
Connor J.A., 1983, Metal carbonyls, Organomet. Chem., 11: 164–177
Cotton F.A., 1976, Basic inorganic chemistry J. Wiley & Sons, 473–495
Froger M., 1981, Etude et mise au point d’un dispositif d’ammincissement par bombardement ionique. Application à l’étude de quelques verres synthétiques et naturels au microscope électronique. Thèse de 3è cycle, Université Strasbourg I.
Gabbi C., Melotti G., Tranquilli-Leali P., Vita Finzi E., 1985 S350 en orthopédie (Priv. Comm.)
Hieber W., Beck W., Zeitler G., 1961, Neuere Anschauungen über Reaktionsweisen der Metall-carbonyle, insbesondere der Mangancarbonyls. Angw. Chem., 73, 11: 364–368
Holland L., 1970, Vacuum deposition of thin films, Chapmann & Hall, London
Melotti G., Vita Finzi E., 1982, L’acciaio inossidable in ortopedia Min. Ortop., 33: 768–773
Muster D., Champy M., 1978, Le problème d’interface os-biomatériaux. Acta odontostomatol, 121: 109–124
Muster D., Jaeger J.H., Bouzouita M., Burggraf C., Baltzinger C. 1982, Application of Physical surface methods to the study of the stability and structure of bone-metal interfaces. Anat. Clin. 4: 183–188
Muster D., Szmukler S., Baltzinger C., Burggraf C., 1982 Fundamentals of bone-metal biocompatibility, J. Dent. Assoc. South Africa, 37: 845–847
Nutt S.R., Wawner F.E., 1981, CVD Coatings from metal carbonyl on SiC filaments, Ceram. Eng. Sci. Proc., 81, 2: 840–848
Pauleau Y., 1985, Les revêtements métallurgiques de tungstène déposés par réaction chimique en phase gazeuse, Bull. Soc. Chim. de France, 4: 583–593
Picraux S.T., Pope L.E., 1984, Tailored surface modification by ion implantation and laser treatment, Science, 226, 4675: 615–622
Sundgren J.E., Bodö P., Lundström I., Berggren A., Hellem S., 1985, Auger Electron spectroscopic studies of stainless-steel implants, J. of Biomed. Mat. Res., 19: 663–671
Sutow E.J., Pollack S.R., 1981, The biocompatibility of certain stainless steels, in: “Biocompatibility of clinical implant materials”, vol.1, DF. Williams, ed., CRC Press, Boca Raton, 45–98
Syrkin V.G., Prokhorov V.N., Ramanova L.N., 1975 Preparation of iron coatings with prescribed properties by a carbonyl method, Zh. Prikl. Khim. (Leningrad), 48: 2487–2490
Szmukler S., 1982, Approche de la stabilité des interfaces osmétal par les méthodes de la physique des surfaces: etude de la corrosion de plaques d’ostéosynthèse, Thèse de Doct. Chir. Dent., Strasbourg.
Szmukler S., 1984, L’adhésion des couches minces Rapport de DEA, Chimie Appliquée, option matériaux, Université de Strasbourg.
Szmukler S., Muster D., Champy M., Baltzinger C., Burggraf C., 1985, Comportement des interfaces osmétal — Approche par les méthodes de la physique des surfaces, in “Actes du Colloque Corrosion et dégradation des biomatériaux et leurs incidences cliniques”, D. Muster, ed., Conseil de l’Europe, Strasbourg, 145–152
Vogt G.J., 1982, Low-temperature chemical vapor deposition of tungsten from tungsten hexacarbonyl, J. Vac. Sci. Technol., 20 (4): 1336–1340
Williams D.F., 1981, The properties and clinical uses of cobalt chromium alloys, in: “Biocompatibility of clinical implant materials”, vol. 1, D.F. Williams, ed., CRC Press, Boca Raton, 99-27
Williams D.F., Askill I.N., Smith R., 1985, Protein adsorption and desorption phenomena on clean metal surfaces, J. Biomed. Mat. Res., 19: 313–320
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1988 Plenum Press, New York
About this chapter
Cite this chapter
Muster, D., Champy, M., Szmukler, S., Baltzinger, C., Burggraf, C. (1988). Surface Treatment of Metallic Biomaterials to Improve Biological and Economical Compatibility. In: Hildebrand, H.F., Champy, M. (eds) Biocompatibility of Co-Cr-Ni Alloys. NATO ASI Series, vol 171. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-0757-0_34
Download citation
DOI: https://doi.org/10.1007/978-1-4613-0757-0_34
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4612-8067-5
Online ISBN: 978-1-4613-0757-0
eBook Packages: Springer Book Archive