Skip to main content

Effect of Phase Delay on Low Frequency Operation of Flux Focusing Eddy Current Probe

  • Chapter
Review of Progress in Quantitative Nondestructive Evaluation
  • 24 Accesses

Abstract

The operation of the Flux Focusing Eddy Current Probe has been found to yield critical information on the thickness of the material being inspected [1–2]. The design of the probe forces the low frequency magnetic fields to diffuse through the sample in order to link with the pickup coil. An attenuation of the magnetic field results such that the pickup coil output is inversely related to the material thickness [2]. In extending the technique to thicker and/or layered materials, however, an apparently anomalous behavior is sometimes seen in which a small increase in the probe output occurs with increasing material thickness. This paper will clarify the underlying principles involved with the probe during low frequency operation and explain the apparent anomaly in terms of the phase shifting of the magnetic field with diffusion depth. A phasor addition model will be presented which accounts for the observed experimental results, and implications of the phenomena on material testing will be discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. B. Wincheski, J. R Fulton, S. Nath, N. Namkung, and J. W. Simpson, “Self-Nulling Eddy Current Probe for Surface and Subsurface Flaw Detection,” in Materials Evaluation, Vol. 52/Number 1 (January 1994).

    Google Scholar 

  2. B. Wincheski, M. Namkung, J. R Fulton, and S. Nath, Review of Progress in QNDE, Vol. 13B, 1611, Plenum Press, New York, 1994.

    Google Scholar 

  3. J. P. Fulton, B. Wincheski, S. Nath and Min Namkung, Review of Progress in QNDE, Vol. 14B, 2317, Plenum Press, New York, 1995.

    Google Scholar 

  4. J. R Fulton, B. Wincheski, S. Nath, and M. Namkung, “Corrosion Detection in Airframes Using a New Flux-Focusing Eddy Current Probe” in Proceeding of ASNT 1994 Spring Conference, 34, 1994.

    Google Scholar 

  5. J. P. Fulton and B. Wincheski, “A New Electromagnetic Technique for Quantifying Material Loss in Aircraft Lapjoints,” presented at 1995 Review of Progress in QNDE, Seattle, Washington.

    Google Scholar 

  6. J. D. Jackson, Classical Electrodynamics, Second Edition, John Wiley & Sons, Inc., New York, 1975.

    Google Scholar 

  7. H. L. Libby, Introduction to Electromagnetic Nondestructive Test Methods, Robert E. Krieger Publishing Co., Inc., Malabar, Florida, 1971.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1996 Plenum Press, New York

About this chapter

Cite this chapter

Wincheski, B., Fulton, J. (1996). Effect of Phase Delay on Low Frequency Operation of Flux Focusing Eddy Current Probe. In: Thompson, D.O., Chimenti, D.E. (eds) Review of Progress in Quantitative Nondestructive Evaluation. Springer, Boston, MA. https://doi.org/10.1007/978-1-4613-0383-1_53

Download citation

  • DOI: https://doi.org/10.1007/978-1-4613-0383-1_53

  • Publisher Name: Springer, Boston, MA

  • Print ISBN: 978-1-4613-8027-6

  • Online ISBN: 978-1-4613-0383-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics