Abstract
The 45-T Hybrid Facility requires 1.8 K refrigeration for extended periods of time. The JT refrigeration system design is fully redundant to guarantee continuous cooling of the super-conducting magnet. Each refrigerator is equipped with a removable instrumentation probe and JT valve plug. These removable components make service and repair possible at 4.2 K. In June of 1995, preliminary testing of the JT refrigerators was performed during the initial cool down of the Hybrid Cryostat. Details of the design, development, and fabrication will be presented along with the results of these early tests.