Skip to main content

A 129-channel Vector Neuromagnetic Imaging System

  • Conference paper
Biomag 96

Abstract

We developed a 129-channel vector neuromagnetic imaging system detecting magnetic fields as a vector value. It is expected that further information can be obtained from vector neuromagnetic field than a conventional system. An axial vector first-order gradiometer was developed as a detection coil, which consists of three first-order differential coils wound on the surface of the same bobbin. These three coils are perpendicular to each other. In addition to a radial component of magnetic fields, two tangential components can be calculated from the measured field at each measuring point. The measuring area with a diameter of nearly 20 cm has 43 measuring points. The DC-SQUID which we developed, adopted a double-washer superconducting ring and employed week link Josephson junctions instead of the conventional tunnel junction. Therefore magnetic flux penetrating the SQUID ring is canceled. In addition, the feedback coil is directly connected with the input coil magnetically so that the current in the detection coil can be canceled by the feedback flux. Therefore a crosstalk between adjacent detection coils is negligible. The read-out electronics is based on the Direct Offset Integration Technique. The system noise in a magnetically shielded room is less than 10fT/Hz1/2 above 10Hz. We confirmed that this system could measure various evoked responses. In this report the features of this system and an application will be shown.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Shinada K. Double Washer de SQUIDs with Short Weak Link.Functions, ISCE95

    Google Scholar 

  2. Drung D., Low-noise high-speed de superconducting quantum interference device magnetometer with simplified feedback electronics, Appl. Phys. Lett., 1990, 57: 406–408

    Google Scholar 

  3. Savas, J. Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem, Phys. Med. Biol. 1987, 32: 11–22

    Article  Google Scholar 

  4. Takanashi Y., Visualization of Tonotopy of Auditory Cortex Using A Newly Developed 129 Channel Vector Magnetoencephalograpy, in this volume

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2000 Springer Science+Business Media New York

About this paper

Cite this paper

Yoshida, Y. et al. (2000). A 129-channel Vector Neuromagnetic Imaging System. In: Aine, C.J., Stroink, G., Wood, C.C., Okada, Y., Swithenby, S.J. (eds) Biomag 96. Springer, New York, NY. https://doi.org/10.1007/978-1-4612-1260-7_39

Download citation

  • DOI: https://doi.org/10.1007/978-1-4612-1260-7_39

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-1-4612-7066-9

  • Online ISBN: 978-1-4612-1260-7

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics