Abstract
Positron emission tomography (PET) imaging has increased substantially in recent years. PET allows noninvasive evaluation of myocardial blood flow, function, and metabolism. The advantages of cardiac PET imaging over SPECT are [1]: improved image quality (especially in obese patients) with high both temporal and spatial resolution, relatively short imaging protocols, routine attenuation correction (depth independent), providing peak stress ejection fraction (EF)-no time delay between hyperemic response and imaging and true quantification of myocardial blood flow and myocardial metabolism. In addition, PET provides equal sensitivity with higher specificity and diagnostic accuracy compared to SPECT. However, cardiac PET still faces the challenges of being less available, with a greater cost, less expertise, challenges of performing exercise stress due to the short half-life of the currently available radiotracers making pharmacological stress testing the only current option (until the availability of new radiopharmaceutical agents), and reimbursement issues.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Dilsizian V, Bacharach SL, Beanlands RS, et al. PET myocardial perfusion and metabolism clinical imaging. Am Soc Nucl Cardiol. 2009. doi:10.1007/s12350-009-9094-9.
Hendel RC, et al. CCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 Appropriate Use Criteria for Cardiac Radionuclide Imaging: a Report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol. 2009;53(23):2201–29.
Klocke FJ, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging – executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 guidelines for the clinical use of cardiac radionuclide imaging). J Am Coll Cardiol. 2003;42(7):1318–33.
Douglas PS, et al. ACCF/ACR/AHA/ASE/ASNC/HRS/NASCI/RSNA/SAIP/SCAI/SCCT/SCMR 2008 health policy statement on structured reporting in cardiovascular imaging. Endorsed by the Society of Nuclear Medicine [added]. Circulation. 2009;119(1):187–200.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2017 Springer-Verlag London
About this chapter
Cite this chapter
Karnabi, E. (2017). Positron Emission Tomography. In: Hendel, R., Kimmelstiel, C. (eds) Cardiology Procedures. Springer, London. https://doi.org/10.1007/978-1-4471-7290-1_9
Download citation
DOI: https://doi.org/10.1007/978-1-4471-7290-1_9
Published:
Publisher Name: Springer, London
Print ISBN: 978-1-4471-7288-8
Online ISBN: 978-1-4471-7290-1
eBook Packages: MedicineMedicine (R0)