Abstract

This chapter analyses the control of the Hybrid Power Sources (HPS) based on some applications performed. Usually, a HPS combines two or more energy sources that work together with the Energy Storage Devices (ESD) to deliver power continuously to the DC load or to the AC load via the inverter system. In the automotive applications, the ESD stack can be charged from the regenerative braking power flow or from other power sources like the thermoelectric generator or the renewable source. The last may have a daily variable power flow such as the photovoltaic panels integrated into a car’s body or into buildings. In the first section, an efficient fuel cell/battery HPS topology is proposed for high power applications to obtain both performances in energy conversion efficiency and fuel cell ripple mitigation. This topology uses an inverter system directly powered from the appropriate Polymer Electrolyte Membrane Fuel Cell (PEMFC) stack that is the main power source and a buck Controlled Current Source (buck CCS) supplied by a batteries stack, which is the low power auxiliary source. The buck CCS is connected in parallel with the main power source, the PEMFC stack. Usually, the FC HPS supply inverter systems and PMFC current ripple normally appear in operation of the inverter system that is grid connected or supply the AC motors in vehicle applications. The Low Frequency (LF) ripple mitigation is based on the active nonlinear control placed in the tracking control loop of the fuel cell current ripple shape. So the buck CCS will generate an anti-ripple current that tracks the FC current shape. This anti-ripple current is injected into the output node of the HPS to mitigate the inverter current ripple. Consequently, the buck CCS must be designed in order to assure the dynamic requested in the control loop. The ripple mitigation performances are evaluated by some indicators related to the LF harmonics mitigation. It is shown that good performances are also obtained with the hysteretic current—mode control, but the nonlinear control has better performances. The nonlinear control of the buck CCS is implemented based on a piecewise linear control law. This control law is simply designed based on the inverse gain that is computed to give a constant answer for all levels of the LF current ripple. The control performances are shown by the simulations performed. Finally, the designed control law will be validated using a Fuzzy Logic Controller (FLC). In the second and the third section is proposed and analysed a nonlinear control for FC HPS based on bi-buck topology that further improves FC performance and its durability in use in the low and medium power applications. The nonlinear voltage control is analysed and designed in the second section using a systematic approach. The design goal is to stabilise the HPS output voltage. This voltage must have a low voltage ripple. Additionally, the power spectrum of this ripple must be spread in a wide frequencies band using an anti-chaos control. All the results have been validated with several simulations.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 129.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 169.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 169.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Kirubakaran A, Jain S, Nema RK (2009) A review on fuel cell technologies and power electronic interface. Renew Sustain Energy Rev 13:2430–2440

    Article  Google Scholar 

  2. Wajiha S, Rahul AK, Arefeen M (2006) Analysis and minimization of input ripple current in PWM inverters for designing reliable fuel cell power systems. J Power Sources 156:448–454

    Article  Google Scholar 

  3. Fontes G (2007) Interactions between fuel cells and power converters: Influence of current harmonics on a fuel cell stack. IEEE T Power Electron 22(2):670–678

    Article  MathSciNet  Google Scholar 

  4. Gemmen RS (2001) Analysis for the effect of the ripple current on fuel cell operating condition. ASME 369(4):279–289

    Google Scholar 

  5. Woojin C, Gyubum J, Prasad NE, Jo WH (2004) An experimental evaluation of the effects of ripple current generated by the power conditioning stage on a proton exchange membrane fuel cell stack. JMEPEG 13:257–264

    Article  Google Scholar 

  6. Schmittinger W, Vahidi A (2008) A review of the main parameters influencing long-term performance and durability of PEM fuel cells. J Power Sources 180:1–4

    Article  Google Scholar 

  7. Auld AE, Smedley KM, Mueller F, Brouwer J, Samuelsen GS (2010) Load-following active power filter for a solid oxide fuel cell supported load. J Power Sources 195:1905–1913

    Article  Google Scholar 

  8. Thounthong P, Raël S, Davat B (2009) Energy management of fuel cell/battery/supercapacitor hybrid power source for vehicle applications. J Power Sources 193(1):376–385

    Article  Google Scholar 

  9. NETL (2001) NETL published fuel cell specifications for future energy challenge 2001 competition (accessed in May 2, 2012, on http://netl.doe.gov)

  10. Thounthong P, Davat B (2010) Study of a multiphase interleaved step-up converter for fuel cell high power applications. Energy Convers Manage 51:826–832

    Article  Google Scholar 

  11. Hwang JC, Chen LH, Yeh SN (2007) Comprehensive analysis and design of multi-leg fuel cell boost converter. Appl Energy 84:1274–1288

    Article  Google Scholar 

  12. Methekar RN, Patwardhan SC, Gudi RD, Prasad V (2010) Adaptive peak seeking control of a proton exchange membrane fuel cell. J Process Control 20:73–82

    Article  Google Scholar 

  13. Zhong ZD, Huo HB, Zhu XJ, Cao GY, Ren Y (2008) Adaptive maximum power point tracking control of fuel cell power plants. J Power Sources 176:259–269

    Article  Google Scholar 

  14. Bizon N (2010) On tracking robustness in adaptive extremum seeking control of the fuel cell power plants. Appl Energy 87(10):3115–3130

    Article  Google Scholar 

  15. Thounthong P, Davat B (2007) A PEM fuel cell power source for electric vehicle applications with supercapacitor or battery as auxiliary. In: Alemo PV, Commack ED (eds.) Progress in fuel CELL research. Nova press, New York (chapter 8)

    Google Scholar 

  16. Lukic SM, Cao J, Bansal RC, Rodriguez F, Emadi A (2008) Energy storage systems for automotive applications. IEEE Trans Ind Electron 55:2258–2267

    Article  Google Scholar 

  17. Kim MJ, Peng H (2007) Power management and design optimization of fuel cell/battery hybrid vehicles. J Power Sources 165:819–832

    Article  Google Scholar 

  18. Tang Y, Yuan W, Pan M, Li Z, Chen G, Li Y (2010) Experimental investigation of dynamic performance and transient responses of a kW-class PEM fuel cell stack under various load changes. Appl Energy 87:1410–1417

    Article  Google Scholar 

  19. Rodatz P, Paganelli G, Sciarretta A, Guzzella L (2005) Optimal power management of an experimental fuel cell/supercapacitor powered hybrid vehicle. Control Eng Practice 13(1):41–53

    Article  Google Scholar 

  20. Thounthong P, Davat B, Raël S, Sethakul P (2009) An overview of power converters for a clean energy conversion technology. IEEE Electronic Mag 3(1):32–46

    Article  Google Scholar 

  21. Thounthong P, Chunkag V, Sethakul P, Sikkabut S, Pierfederici S, Davat B (2010) Energy management of a fuel cell/solar cell/supercapacitor hybrid power source. J Power Sources 196(1):313–324

    Article  Google Scholar 

  22. Corbo P, Corcione FE, Migliardini F, Veneri O (2009) Experimental study of a fuel cell power train for road transport application. J Power Sources 145:610–619

    Article  Google Scholar 

  23. Uzunoglu M, Alam MS (2006) Dynamic modeling, design, and simulation of a combined PEM fuel cell and ultracapacitor system for standalone residential applications. IEEE T Energy Conver 21:767–775

    Article  Google Scholar 

  24. Xu L, Li J, Hua J, Li X, Ouyang M (2009) Adaptive supervisory control strategy of a fuel cell/battery-powered city bus. J Power Sources 194:360–368

    Article  Google Scholar 

  25. Bizon N, Lefter E, Oproescu M (2007) Modeling and Control of the energy sources power interface for automotive hybrid electrical system. In: 21st JUMV international automotive Conference on science and motor vehicles, paper NMV0752—Pages 12 (accessed in May 2, 2012, on http://riedal-dz.com/resources/52_bizon.pdf)

  26. Bizon N, Oproescu M (2010) Control performances of the bi-buck interface used for inverter current ripple compensation. Int J Tech Phys Prob Eng 1(1):5–10

    Google Scholar 

  27. Bizon N (2010) Development of a fuel cell stack macro-model for inverter current ripple evaluation. Rev Roum Sci Techn–Électrotechn et Énerg 55(4):405–415

    Google Scholar 

  28. Woojin C, Jo HW, Prasad E (2006) Development of an equivalent circuit model of a fuel cell to evaluate the effects of inverter ripple current. J Power Sources 158:1324–1332

    Article  Google Scholar 

  29. Kim JS, Choe GY, Kang HS, Lee BK (2010) Effect of load modeling on low frequency current ripple in fuel cell generation systems. J Electr Eng Technol 5:307–318

    Article  Google Scholar 

  30. Spiegel C (2008) PEM fuel cell modeling and simulation using MATLAB, Elsevier Press, Amsterdam

    Google Scholar 

  31. Gou B, Na WK, Diong B (2010) Fuel cells: modeling, control, and applications. CRC Press, (chapter 3):13–52

    Google Scholar 

  32. Payman A, Pierfederici S, Tabar FM (2008) Energy control of supercapacitor/fuel cell hybrid power source. Energy Convers Manage 49:1637–1644

    Article  Google Scholar 

  33. Bizon N (2011) Nonlinear control of fuel cell hybrid power sources: Part I–Voltage control. Appl Energy 88(7):2559–2573

    Article  Google Scholar 

  34. Bizon N (2011) Nonlinear control of fuel cell hybrid power sources: Part II –current control. Appl Energy 88(7):2574–2591

    Article  Google Scholar 

  35. Bizon N (2011) A new topology of fuel cell hybrid power source for efficient operation and high reliability. J Power Sources 196(6):3260–3270

    Article  Google Scholar 

  36. Wang Y, Choi Y, Lee E (2009) Efficient and ripple-mitigating dc–dc converter for residential fuel cell system. Electr Power Energy Syst 31:43–49

    Article  Google Scholar 

  37. Kim JS, Choe GY, Kang HS, Lee BK (2011) Robust low frequency current ripple elimination algorithm for grid-connected fuel cell systems with power balancing technique. Renewable Energy 36:1392–1400

    Article  Google Scholar 

  38. Bizon N (2008) Control of the Bi-buck power interface used for inverter current ripple minimization. Sci J of the Electrical Eng Facult Valahia Univ 1:7–12

    Google Scholar 

  39. Bizon N (2009) DC–DC converter operation with power spectrum spreading using a nonlinear control law. Mediterr J Meas Control 5(2):78–90

    Google Scholar 

  40. Bizon N, Raducu M, Oproescu M (2008) Fuel cell current ripple minimization using a bi-buck power interface. In: 13th IEEE international power electronics and motion control conference 2008, IEEE Catalog CFP0834A-CDR 1:621–628

    Google Scholar 

  41. Morel C, Bourcerie M, Chapeau-Blondeau F (2005) Improvement of power supply electromagnetic compatibility by extension of chaos anticontrol. J Circuits, Syst, Comput 14(4):757–770

    Article  Google Scholar 

  42. Bizon N (2009) DC–DC converter operation with power spectrum spreading using a nonlinear control law. Mediterr J Meas Control 5(2):78–90

    Google Scholar 

  43. Liu C, Lai JS (2007) Low frequency current ripple reduction technique with active control in a fuel cell power system with inverter load. IEEE Trans Power Elect 22(4):1453–1463

    Article  Google Scholar 

  44. Bizon N (2013) Energy harvesting from the FC stack that operates using the MPP tracking based on modified extremum seeking control. Appl Energy 104:326–336

    Article  Google Scholar 

  45. Bizon N (2013) FC energy harvesting using the MPP tracking based on advanced extremum seeking control. Int J Hydrogen Energy 38(14):1952–1966

    Article  Google Scholar 

  46. Bizon N (2012) Energy efficiency for the multiport power converters architectures of series and parallel hybrid power source type used in plug-in/V2G fuel cell vehicles. Appl Energy 102:726–734

    Article  Google Scholar 

  47. Bizon N (2012) Energy efficiency of multiport power converters used in plug-in/v2g fuel cell vehicles. Appl Energy 96:431–443

    Article  Google Scholar 

Download references

Acknowledgments

Some figures, tables and text are reproduced from [3335] here with kind permission from Elsevier Limited, UK [February 16, 2013].

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nicu Bizon .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2013 Springer-Verlag London

About this chapter

Cite this chapter

Bizon, N., Oproescu, M., Raducu, M. (2013). Applications in Control of the Hybrid Power Systems. In: Bizon, N., Shayeghi, H., Mahdavi Tabatabaei, N. (eds) Analysis, Control and Optimal Operations in Hybrid Power Systems. Green Energy and Technology. Springer, London. https://doi.org/10.1007/978-1-4471-5538-6_7

Download citation

  • DOI: https://doi.org/10.1007/978-1-4471-5538-6_7

  • Published:

  • Publisher Name: Springer, London

  • Print ISBN: 978-1-4471-5537-9

  • Online ISBN: 978-1-4471-5538-6

  • eBook Packages: EnergyEnergy (R0)

Publish with us

Policies and ethics