Abstract
Almost without exception, modern nuclear medicine images are acquired using a gamma camera based on the principles first suggested by Anger in 1957 (Fig. 4.1).1 The camera consists of a scintillation detector made of a single sodium iodide crystal which is typically between 200 mm and 500 mm diameter and between 6 and 20 mm thick. Behind the crystal are a number of photomultiplier tubes (up to 90 or 100) which are optically coupled to the surface of the crystal and which sense the scintillations arising whenever a gamma ray is absorbed by the crystal. The areas of crystal seen by the tubes overlap, but the location of each scintillation can be computed from the relative responses in each tube. The energy of the photons can also be measured from the response of the tubes, and the electrical output from the camera head to the imaging computer consists of x and y coordinates and photon energy (z) for each scintillation that is detected. In front of the crystal is a collimator which consists of a disc of lead penetrated by a honeycomb of holes. The holes allow only gamma rays that are travelling perpendicularly to the crystal face to enter the crystal and in this way the gamma photons absorbed by the crystal form an image of the distribution of radionuclide in front of the camera.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
Anger H. Scintillation camera. The review of scientific instruments 1958;29:27–33.
Kuhl DE, Edwards RQ. Image separation radioisotope scanning. Radiology 1963;80:653–61.
Hounsfield GN. Computerised transverse axial scanning (tomography). 1 Description of system. Br J Radiol 1973;46:1016–22.
Ambrose J. Computerised transverse axial scanning (tomography). 2 Clinical application. Br J Radiol 1973;46:1023–47.
Moore ML, Murphy PH, Burdine JA. ECG-gated emission computed tomography of the cardiac blood pool. Radiology 1980;134:233–5.
Maublant J, Bailly P, Mestas D et al. Feasibility of gated single-photon emission transaxial tomography of the cardiac blood pool. Radiology 1983;146:837–9.
Tamaki N, Mukai T, Ishii Y et al. Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera. Radiology 1983;147: 547–54.
Underwood SR, Walton S, Ell PJ, Jarritt PH, Emanuel RW, Swanton RH. Gated blood-pool emission tomography: a new technique for the investigation of cardiac structure and function. Eur J Nucl Med 1985;10:332–7.
Ell PJ, Holman BL. Computed emission tomography. Oxford: Oxford Medical Publications, 1982.
Ell PJ, Jarritt PH. Gamma camera emission tomography: quality control and clinical applications. London: Chapman and Hall, 1984.
Hoffman EJ. 180° compared with 360° sampling in SPECT. J Nucl Med 1982;23:745–7.
Coleman RE, Jaszczak RJ, Cobb FR. Comparison of 180 deg and 360 deg data collection in thallium-201 imaging using single photon emission computed tomography (SPECT). J Nucl Med 1982;23:655–60.
Go RT, McIntyre WJ, Houser TS et al. Clinical evaluation of 360° and 180° data sampling techniques for transaxial SPECT thallium-201 myocardial perfusion imaging. J Nucl Med 1985;26:695–706.
Knesaurek K. Image distortion in 180° SPECT studies. J Nucl Med 1986;27:1792.
Penneil DJ, Underwood SR, Ell PJ, Swanton RH, Walker JM, Longmore DB. Dipyridamole magnetic resonance imaging: a comparison with thallium-201 emission tomography. Br Heart J 1990;64:362–9.
Author information
Authors and Affiliations
Rights and permissions
Copyright information
© 1992 Springer-Verlag London Limited
About this chapter
Cite this chapter
Pennell, D.J., Underwood, S.R., Costa, D.C., Ell, P.J. (1992). Imaging Techniques. In: Thallium Myocardial Perfusion Tomography in Clinical Cardiology. Springer, London. https://doi.org/10.1007/978-1-4471-1857-2_4
Download citation
DOI: https://doi.org/10.1007/978-1-4471-1857-2_4
Publisher Name: Springer, London
Print ISBN: 978-1-4471-1859-6
Online ISBN: 978-1-4471-1857-2
eBook Packages: Springer Book Archive