Alumina on Polyethylene Bearings

  • Chapter
Interfaces in Total Hip Arthroplasty
  • 192 Accesses

Abstract

John Charnley introduced metal on polyethylene (PE) articulation for total hip replacement in the early 1960s. His experience with polytetrafluorethylene (PTFE) made him acutely conscious of the problem of wear, but he estimated that this would be a mean of 0.1 mm per year, and would not represent a problem.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

eBook
USD 16.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 16.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Hummer CD 3rd, Rothman RH, Hozack WJ. Catastrophic failure of modular zirconia-ceramic femoral head components after total hip arthroplasty. J Arthroplasty 1995;10(6):848–850.

    Article  Google Scholar 

  2. Dorlot JM. Long-term effects of alumina components in total hip prostheses. Clin Orthop 1992;282:47–52.

    PubMed  Google Scholar 

  3. Jenny JY, Boeri C, Tavan A, Schlemmer B. Résultats en fonction du couple de frottement. In: Symposium sur les prothèses totales de hanche avant 50 ans (Directeurs: L Pidhorz et L Sedel) Revue Chir Orthop 1998; Suppll, 84:75–120.

    Google Scholar 

  4. Kawauchi K, Kuroki Y, Saito S et al. Total hip endopros-theses with ceramic head and HDP socket. Clinical wear rate. In: Oonishi H and Ooi Y (eds) Orthopaedic ceramic implants. Japanese Society of Orthopaedic Ceramic Implants, 1984;4:253-257.

    Google Scholar 

  5. Oonishi H, Takayaka Y, Clarke I, Jung H. Comparative wear studies of 28-mm ceramic and stainless steel total hip joints over 2 to 7 year period. CRC press. J Long-term Effects M Implants 1992;2(1):37–47.

    Google Scholar 

  6. Davidson JA. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear. Clin Orthop 1993;294:361–378.

    PubMed  Google Scholar 

  7. Bragdon CR, Jasty M, Kawate K et al. Wear of retrieved cemented polyethylene acetabula with alumina femoral heads. J Arthroplasty 1997;12(2):119–125.

    Article  Google Scholar 

  8. Clarke IC, Willmann G. Structural ceramics in orthopedics. In: Cameron HE (ed) Bone implant interface. St. Louis, MO: Mosby, 1994; 203–252.

    Google Scholar 

  9. Heck DA, Partridge CM, Reuben JD, Lanzer WL, Lewis CG, Keating EM. Prosthetic failures in hip arthroplasty surgery. J Arthroplasty 1995;10:575–580.

    Article  PubMed  CAS  Google Scholar 

  10. Dumbleton JH, Miller DA. A simulator for load bearing joints. Wear 1972;20:165–174.

    Article  Google Scholar 

  11. McKellop HM, Clarke IC, Maelkorf KL, Amstutz HC. Friction and wear properties of polymer metal and ceramic prosthetic joints materials evaluated on a multichannel screening device. J Biomed Mat Res 1981;15:619–653.

    Article  CAS  Google Scholar 

  12. Wroblewski BM, Siney PD, Dowson D, Collins SN. Prospective clinical joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg 1996;78B, 280–285.

    Google Scholar 

  13. Sedel L. Tribology of total hip replacement. Instructional Course Lecture. EFORT meeting, Barcelona, 1997. Edited by P Fulford and J Duparc.

    Google Scholar 

  14. Simon JA, Dayan AJ, Ergas E, Stuchin SA, Dicesare PE. Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty. J Arthroplasty 1998;13(1):108–113.

    Article  Google Scholar 

  15. Caravia L, Dowson D, Fischer J, Jobbins B. The influence of bone and bone cement debris on counterface roughness in sliding wear tests of ultra high molecular weight polyethylene on stainless steel. Eng Med 1990;204:65–70.

    Article  CAS  Google Scholar 

  16. Cooper JR, Dowson D, Fisher J, Jobbins B. Ceramic bearing surfaces in total artificial joints resistance to third body wear damage from bone cement particles. J Med Eng Technol 1991;15(2):63–67.

    Article  Google Scholar 

  17. Isaac GH, Arkinson JR, Dowson D, Kennedy PD, Smith MR. The causes of femoral head roughening in explanted Charnley hip prostheses. Eng Med 1987;16(3):167–173.

    Article  Google Scholar 

  18. Weightman BO, Swanson SAV, Isaac GH, Wroblewski BM. Polyethylene wear from retrieved acetabular cups. J Bone Joint Surg 1991;73B(5):806–881.

    Google Scholar 

  19. Davidson JA, Poggie RA, Mishra AK. Abrasive wear of ceramic, metal and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris. Biomed Mater Eng 1994;4(3):213–229.

    Google Scholar 

  20. Kempf I, Semlith M. Massive wear of a steel ball head by ceramic fragments in the polyethylene acetabular cup after revision of a total hip prosthesis with fractured ceramic ball. Arch Orthop Trauma Surg 1990;109(5):284–287.

    Article  Google Scholar 

  21. Bergmann G, Graichen F, Rohlmann A. In vivo measurement of temperature rise in a hip implant. Proceedings 37th Annual Meeting Orthopaedic Research Society, Anaheim, USA, 1991; 223.

    Google Scholar 

  22. Kumar P, Oka M, Ikeuchi K et al. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J Biomed Mater Res 1991;25(7):813–828.

    Article  PubMed  CAS  Google Scholar 

  23. Boher C. Simulation expérimentale du comportement tribologique des matériaux prothétiques de la hanche. Thèse en sciences des matériaux, Toulouse, 1992.

    Google Scholar 

  24. Streicher RM, Semlitsch M, Schön R. Ceramic surfaces as wear partners for PE. In: Bonfield W, Hastings GW, Tanner KE (eds) Bioceramics 4 (Proceedings of the 4th International Symposium on Ceramics in Medicine), London, 1991; 9-16.

    Google Scholar 

  25. Clarke IC, Gustafson A, Jung H, Fujisawa A. Hip-simulator ranking of polyethylene wear: comparisons between ceramic heads of different sizes. Acta Orthop Scand 1996;67(2): 128–132.

    Google Scholar 

  26. Clarke IC. Optimal wear performance of ceramic on ceramic bearings for THR. Proc Annual Japanese Joint Arthroplasty. Kanazawa, Japan, 1998; 1, In press.

    Google Scholar 

  27. Zichner LP, Willert HG. Comparison of alumina-polyethylene and metal-polyethylene in clinical trials. Clin Orthop 1992;282:86–94.

    PubMed  Google Scholar 

  28. Zichner L, Lindenfeld T. In vivo wear of the slide combinations ceramic-polyethylene as opposed to metal-polyethylene. Orthopade 1997;26(2):129–134.

    Google Scholar 

  29. Schuller HM, Marti RK. Ten-year socket wear in 66 arthro-plasties. Ceramic versus metal heads. Acta Orthop Scand 1990;61(3):240–243.

    Google Scholar 

  30. Sugano N, Nishii T, Nakata K, Mashura K, Takaoka K. Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten year study. J Bone Joint Surg 1995;77B (4):548–556.

    Google Scholar 

  31. Le Mouel S, Allain J, Goutallier D. Analyse actuarielle à 10 ans d’une cohorte de 156 prothèses totales de hanche cimentées à couple de frottement alumine/polyethylene. Rev Chir Orthop 1998;84(4):338–345.

    Google Scholar 

  32. McKellop HA, Sarmiento A, Brien W, Park SH. Interface corrosion of a modular head total hip arthroplasty. J Arthroplasty 1992;7(3):291–294.

    Article  Google Scholar 

  33. Black J. Metal on metal bearings, a practical alternative. Clin Orthop 1996;329S:244–255.

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2000 Springer-Verlag London

About this chapter

Cite this chapter

Sedel, L. (2000). Alumina on Polyethylene Bearings. In: Learmonth, I.D. (eds) Interfaces in Total Hip Arthroplasty. Springer, London. https://doi.org/10.1007/978-1-4471-0477-3_12

Download citation

  • DOI: https://doi.org/10.1007/978-1-4471-0477-3_12

  • Publisher Name: Springer, London

  • Print ISBN: 978-1-4471-1150-4

  • Online ISBN: 978-1-4471-0477-3

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics