Abstract
Spectrometers have been developed to record x-ray spectra in the energy range 50 eV to 60 keV. The dispersion elements are transmission crystals for energies higher than approximately 11 keV, reflection crystals for 1 keV to 20 keV, and transmission gratings for energies less than 1 keV. The spectra are recorded on CCD or CMOS detectors with phosphor conversion screens. Silicon photodiodes are positioned in front of the detectors to provide absolute x-ray flux calibrations. The diodes have 1 mm2 area and subnanosecond time response. The diodes, transmission gratings, and attenuation filters were absolutely calibrated using synchrotron radiation. In addition, the diodes were calibrated in pulsed mode using the soft x-ray (70 eV to 250 eV) pulses from individual electron bunches circulating in the storage ring, and a self-calibration model extends the calibration to higher energy. X-ray spectra in the energy range >12 keV were recorded at the OMEGA laser using a transmission crystal. Spectra in the energy range <1 keV were recorded at the NIKE laser using a transmission grating and fast silicon photodiodes. A NIF core diagnostic is being built that covers the 1–20 keV range with one transmission crystal and four reflection crystals.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
References
J. Seely, R. Deslattes, L. Hudson, G. Holland, R. Atkin, D. Meyerhofer, and C. Stoeckl, X-ray spectra in the 12–60 keV energy range from plasmas produced by the OMEGA laser, in Applications of X Rays Generated from Lasers and Other Bright Sources II, ed. by G. Kyrala and J.-C. Gauthier, SPIE vol. 4504(in press).
R. D. Deslattes, J. C. Levin, M. D. Walker, and A. Henins, Noninvasive high-voltage measurement in mammography by crystal diffraction spectrometry,”Med. Phys. 21, 123 (1994).
J. F. Seely, C. Back, R. Deslattes, L. Hudson, G. Holland, P. Bell, and M. Miller, Hard x-ray spectrometers for the National Ignition Facility, Rev. Sci. Instr. 72, 2562 (2001).
J. Weaver, G. Holland, U. Feldman, J. Seely, C. Brown, V. Serlin, A. Deniz, and M. Klapisch, The determination of absolutely calibrated spectra from laser produced plasmas using a transmission grating spectrometer at the NIKE laser facility, Rev. Sci. Instr. 72, 108 (2001).
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2002 Springer Science+Business Media New York
About this chapter
Cite this chapter
Seely, J., Feldman, U., Weaver, J., Hudson, L. (2002). X-Ray Spectroscopy and Calibrations in the 50 Ev to 60 Kev Range. In: Stott, P.E., Wootton, A., Gorini, G., Sindoni, E., Batani, D. (eds) Advanced Diagnostics for Magnetic and Inertial Fusion. Springer, Boston, MA. https://doi.org/10.1007/978-1-4419-8696-2_44
Download citation
DOI: https://doi.org/10.1007/978-1-4419-8696-2_44
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4613-4669-2
Online ISBN: 978-1-4419-8696-2
eBook Packages: Springer Book Archive