Skip to main content

Automatic Detection of Motion Artifacts in Infant Functional Optical Topography Studies

  • Conference paper
  • First Online:
Oxygen Transport to Tissue XXXI

Part of the book series: Advances in Experimental Medicine and Biology ((AEMB,volume 662))

Abstract

A key advantage of optical topography (OT) for cognitive neurodevelopmental studies over other imaging techniques such as magnetic resonance (MRI) or positron emission tomography (PET) is that it is less intrusive in the experimental set up. This is, in part, because in OT there is no need to impose strict movement constraints on the participants. However, large head movements can cause signal disruption, thus there is a need to (i) detect artifacts caused by movement and (ii) implement strategies to remove the noise component from the optical data. We have developed a motion sensor compatible with our in-house OT system and suitable for infant studies. With the data collected we have adjusted the thresholds that were used in the past to automatically discard data affected by movement artifacts. We have also compared the performance of two different head probe designs by measuring the amount of signal disruption present in recordings with each design. Finally, we have studied the feasibility of using the sensor data as external input of an adaptive filter to reduce the movement component of the optical data.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 259.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 329.00
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 329.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Hoshi Y (2007) Functional near-infrared spectroscopy: current status and future prospects. J Biomed Opt doi: 10.1117/1.2804911

    Google Scholar 

  2. Matthews F, Pearlmutter BA, Ward TE, Soraghan C, Markham C (2008) Hemodynamics for Brain-Computer Interfaces (Optical correlates of control signals). IEEE Signal Processing Magazine. doi: 10.1109/MSP.2007.909011

    Google Scholar 

  3. Pena M, Maki A, Kovacic D, Dehaene-Lambertz G, Koizumi H, Bouquet F, Mehler J (2003) Sounds and silence: an optical topography study of language recognition at birth. Proc Natl Acad Sci 100:11702–11075

    Article  PubMed  CAS  Google Scholar 

  4. Blasi A, Fox S, Everdell N, Volein A, Tucker L, Csibra G, Gibson AP, Hebden JC, Johnson MH, Elwell CE (2007) Investigation of depth dependent changes in cerebral haemodynamics during face perception in infants. Phys Med Biol 52:6849–6864

    Article  PubMed  CAS  Google Scholar 

  5. Everdell NL, Gibson AP, Tullis IDC, Vaithianathan T, Hebden JC, Delpy DT (2005) A frequency multiplexed near-infrared topography system for imaging functional activation in the brain. Rev Sci Instrum doi: 10.1063/1.2038567

    Google Scholar 

  6. Izzetoglu M, Izzetoglu K, Bunce S, Onaral B (2003) Motion Artifact Removal in fNIR Signals Using Adaptive Filtering. Proc. of IEEE BMES 2003

    Google Scholar 

  7. Lloyd-Fox S, Blasi A, Volein A, Everdell N, Elwell CE, Johnson MH (2009) Social perception in infancy: a near infrared spectroscopy study. Accepted in Child Development. Child Dev 80:986–999

    Google Scholar 

  8. Grossman T, Johnson MH, Lloyd-Fox S, Blasi A, Deligianni F, Elwell C, Csibra G (2008) Early cortical specialization for face-to-face communication in human infants. Proc R Soc B doi:10.1098

    Google Scholar 

  9. Haykin S (1996) Recursive Least-Squares Algorithm. In: Kailath T (ed.) Adaptive Filter Theory, 3rd edn. Upper Saddle River, New Jersey:Prentice Hall

    Google Scholar 

  10. Izzetoglu M, Devaraj A, Bunce S, Onaral B (2005) Motion artifact cancellation in NIR spectroscopy using Wiener Filtering, IEEE Trans Biomed Eng 52:934–938

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Anna Blasi .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2010 Springer Science+Business Media, LLC

About this paper

Cite this paper

Blasi, A., Phillips, D., Lloyd-Fox, S., Koh, P.H., Elwell, C.E. (2010). Automatic Detection of Motion Artifacts in Infant Functional Optical Topography Studies. In: Takahashi, E., Bruley, D. (eds) Oxygen Transport to Tissue XXXI. Advances in Experimental Medicine and Biology, vol 662. Springer, Boston, MA. https://doi.org/10.1007/978-1-4419-1241-1_40

Download citation

Publish with us

Policies and ethics