The roof is the most vulnerable part of a building and hence its performance requirements have to be stringent. Although most roofs are structurally stable, problems do occur because of poor design and construction. All roof coverings are expected to be durable under a wide range of conditions. But this durability is often short-lived because the roof is invariably exposed to the extremes of temperature, solar radiation, snow loadings and wind action as well as to chemical, biological and mechanical agents.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Related and Further Reading

  1. Addleson, L. Building Failures: A Guide to Diagnosis, Remedy and Prevention. Architectural Press, London (1982).Google Scholar
  2. Bisset, A. H. How a flat roof failure occurs. Buildings, Maintenance and Services (November, 1978).Google Scholar
  3. British Standards Institution. CP 143: Parts 1–16 (1958–74) Code of Practice for sheet roof and wall coverings.Google Scholar
  4. British Standards Institution. BS 5247: Part 14: 1975 Code of Practice for sheet roof and wall coverings, corrugated asbestos cement.Google Scholar
  5. British Standards Institution. BS 6229: 1982 Code of Practice for flat roofs with continuously supported coverings.Google Scholar
  6. British Standards Institution. 8S 6577: 1985 Specification for mastic asphalt for building (natural rock asphalt aggregate).Google Scholar
  7. British Standards Institution. BS 747: 1977 (1986) Specification for roofing felts.Google Scholar
  8. British Standards Institution. BS 6925: 1988 Specification for mastic asphalt for building and engineering (limestone aggregate).Google Scholar
  9. British Standards Institution. BS 5534: Part 1: 1990 Code of Practice for slating and tiling Part 1, Design.Google Scholar
  10. Building Research Establishment, UK. Asphalt and Built-up Felt Roofing: Durability. Digest 144 (1972).Google Scholar
  11. Building Research Establishment, UK. Slated or Tiled Pitched Roofs: Ventilation to Outside Air. Defect Action Sheet 1 (1982).Google Scholar
  12. Building Research Establishment, UK. Slated or Tiled Pitched Roofs: Restricting the Entry of Water Vapour from the House. Defect Action Sheet 3 (1982).Google Scholar
  13. Building Research Establishment, UK. Pitched Roofs: Thermal Insulation Near the Eaves. Defect Action Sheet 4 (1982).Google Scholar
  14. Building Research Establishment, UK. Pitched Roofs: Sarking Felt Underlay — Drainage from Roof. Defect Action Sheet 9 (1982).Google Scholar
  15. Building Research Establishment, UK. Condensation in Insulated Domestic Roofs. Digest 270 (1983).Google Scholar
  16. Building Research Establishment, UK. Felted Cold Deck Flat Roofs Remedying Condensation by Converting to Warm Deck. Defect Action Sheet 59 (1984).Google Scholar
  17. Building Research Establishment, UK. Flat Roof Design: The Technical Options. Digest 312 (1986).Google Scholar
  18. Building Research Establishment, UK. Cavity Parapets — Avoiding Rain Penetration. Defect Action Sheet 106 (1987).Google Scholar
  19. Building Research Establishment, UK. Flat Roof Design: Thermal Insulation. Digest 324 (December, 1987).Google Scholar
  20. Building Research Establishment, UK. Mastic Asphalt for Flat Roofs:Testing for Quality Assurance. Information Paper 8/91 (May, 1991).Google Scholar
  21. Ellis, N., Hutchinson, B. D. and Barton, J. Maintenance and Repair of Buildings. Butterworth, London (1975).Google Scholar
  22. Hinks, J. and Cook, G. Metal roofs need regular inspection for damage. Building Today (18 May 1989).Google Scholar
  23. Holden, C. Roofs, renew or patch: Which is the best policy? Buildings, Maintenance and Services (July/August, 1976).Google Scholar
  24. March, F. Flat Roofing: A Guide to Good Practice. Tarmac Building Products Ltd, UK (1982).Google Scholar
  25. Property Services Agency. Technical Guide to Flat Roofing. Department of the Environment, UK (March, 1987).Google Scholar
  26. Property Services Agency. Parapet Gutters - Rain Penetration. Feedback Digest, Technical File No. 1 (April, 1988).Google Scholar
  27. Ransom, W. H. Building Failures: Diagnosis and Avoidance. Spon, London (1987).Google Scholar
  28. Royal Institution of Chartered Surveyors. A Practical Approach to Flat Roof Covering Problems - Guidance Note. Surveyors Publications, London (1985).Google Scholar
  29. Seeley, I. H. Building Maintenance, 2nd edn. Macmillan, London (1987).Google Scholar
  30. Thornton, M. Lead for roofing. Traditional Homes (October, 1988 ).Google Scholar

Copyright information

© Lee How Son and George C. S. Yuen 1993

Authors and Affiliations

  • Lee How Son
    • 1
  • George C. S. Yuen
    • 1
  1. 1.Building DepartmentNgee Ann PolytechnicSingapore

Personalised recommendations