Skip to main content

Experimental Membrane Oxygenators with Convective Mixing for Gas Transfer Augmentation

  • Chapter
Artificial Organs

Part of the book series: Strathclyde Bioengineering Seminars ((KESE))

  • 22 Accesses

Summary

Principle of operation, design and oxygenation performance of three membrane oxygenators employing convective mixing for enhanced gas transfer are described. Two oxygenators are of curved rectangular channel geometry, one with vortex formation induced by pressure driven flow and the second with vortices generated by torsional oscillation of the channel. The third oxygenator is of the capillary membrane type incorporating a chamber which functions as a mixing stage and a blood pump. The efficiencies of the units are compared with existing membrane oxygenators and design optimisation of the most promising system is presented.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  • Bartlett, R. H., Drinker, P. A., Burns, N. E., Fong, S. W. and Hyans, T. (1972). The toroidal membrane oxygenator: Design, performance and prolonged bypass testing of a clinical model. Trans. Amer. Soc. Artif. Int. Organs, 18, 369.

    Article  CAS  Google Scholar 

  • Bellhouse, B. J., Bellhouse, F. H., Curl, C. M., MacMillan, T. I., Gunning, A. J., Spratt, E. H., MacMurray, S. B. and Nelems, J. M. (1973). A high efficiency membrane oxygenator and pulsatile pumping system, and its application to animal trials. Trans. Amer. Soc. Artif. Int. Organs, 19, 72.

    Article  CAS  Google Scholar 

  • Chang, H. K. and Mockros, L. F. (1971). Convective dispersion of blood gases in curved channel exchangers. Amer. Inst. Chem. Eng. J., 17, 541.

    Article  Google Scholar 

  • Dean, W. R. (1928). Fluid motion in a curved channel. Proc. Roy. Soc. (London),A, 121, 402.

    Article  Google Scholar 

  • Drinker, P. A., Bartlett, R. H., Bialer, R. M. and Noyes, B. S. (1969). Augmentation of membrane gas transfer by induced secondary flows. Surgery, 66, 775.

    PubMed  CAS  Google Scholar 

  • Galletti, P. M., Richardson, P. D., Snider, M. T. and Friedman, L. I. (1972). A standardised method for defining the overall gas transfer performance of artificial lungs. Trans. Amer. Soc. Artif. Int. Organs, 18, 359.

    Article  CAS  Google Scholar 

  • Gaylor, J. D. S., Murphy, J. F., Caprini, J. A., Zuckerman, L. and Mockros, L. F. (1973). Gas transfer and thrombogenesis in an annular membrane oxygenator with active blood mixing. Trans. Amer. Soc. Artif. Int. Organs, 19, 516.

    Article  CAS  Google Scholar 

  • Gilroy, K. (1976). Secondary flow augmented mass transfer in annular membrane oxygenators. Ph.D. Thesis, University of Strathclyde, Glasgow.

    Google Scholar 

  • Gilroy, K., Brighton, E. and Gaylor, J. D. S. (1977). The influence of fluid vortices on mass transfer in a curved channel artificial membrane lung. Amer. Inst. Chem. Eng. J., 23, 106.

    Article  CAS  Google Scholar 

  • Hill, J. D., Iatridis, A., O’Keefe, R. and Kitrilakis, S. (1974). Technique for achieving high gas exchange rates in membrane oxygenation. Trans. Amer, Soc. Artif. Int. Organs, 20, 249.

    Google Scholar 

  • Mockros, L. F. and Weissman, M. H. (1971). The artificial lung, in J. H. U. Brown,J. E. Jacobs, and L. Stark, (Eds.), Biomedical Engineering, Davis Company,California, p. 325. Reid, W. H. (1958). On the stability of viscous flow in a curved channel. Proc. Roy. Soc. (London), A 244, 186.

    Google Scholar 

  • Smeby, L. C. and Grimsrud, L. (1974). Theoretical investigation of mass transfer in membrane oxygenators. Med. BioL Engng., 12, 698.

    Article  CAS  Google Scholar 

  • Ton, H. Y. (1975). Design of a tubular membrane oxygenator with integral pumping. M.Sc. Thesis, University of Strathclyde, Glasgow.

    Google Scholar 

Download references

Authors

Editor information

Editors and Affiliations

Copyright information

© 1977 Bioengineering Unit, University of Strathclyde

About this chapter

Cite this chapter

Gaylor, J.D.S., Gilroy, K., Maini, R., McNair, A., Ton, H.Y. (1977). Experimental Membrane Oxygenators with Convective Mixing for Gas Transfer Augmentation. In: Kenedi, R.M., Courtney, J.M., Gaylor, J.D.S., Gilchrist, T., Gerard, S.M. (eds) Artificial Organs. Strathclyde Bioengineering Seminars. Palgrave, London. https://doi.org/10.1007/978-1-349-03458-1_7

Download citation

Publish with us

Policies and ethics